ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.
Flexible molecular docking is a computational method of structure-based drug design to evaluate binding interactions between receptor and ligand and identify the ligand conformation within the receptor pocket. Currently, various molecular docking programs are extensively applied; therefore, realizing accuracy and performance of the various docking programs could have a significant value. In this comparative study, the performance and accuracy of three widely used non-commercial docking software (AutoDock Vina, 1-Click Docking, and UCSF DOCK) was evaluated through investigations of the predicted binding affinity and binding conformation of the same set of small molecules (HIV-1 protease inhibitors) and a protein target HIV-1 protease enzy
... Show MoreThe study aims to build a model that enhances trust-building for public and private banks to compare and determine the significant differences between public and private banks, by testing the impact of governance mechanisms (transparency, accountability, justice, independence, and social responsibility) (Agere, 2000) on trust-building strategies (trust and trust building, people management, work relations, training and development, leadership practices, and communications) (Ngalo, 2011; Stone et al., 2005), to indicate the level of employees’ awareness of the theoretical contents of the two variables and their importance to banking work, with the aim of improving performance. The main question is the role of governance mechanisms
... Show MoreComparative Study Between Glimepiride and Glibenclamide in the Treatment of Type 2 Diabetic Patients in Al-Yarmouk Hospital
Some feline intestinal parasites such as Toxocara, Giardia, and Cryptosporidium can spread to humans through feces. Therefore, it is important to prevent exposure of family members by screening cat fecal samples twice per year for potential treatment regimes. This study was initiated to compare and identify gastrointestinal parasites of domestic and stray cats (Felis domesticus) in Baghdad City, Iraq. Parasite eggs and oocysts were identified under light microscopy by applying standard laboratory techniques (flotation and sedimentation). Overall, 59 of 121 (48.7%) fecal samples were positive for intestinal parasites. The rate of infection by Toxoplasma gondii was (3.31%), Isospora spp. (6.61%), Cryptosporidium spp. (31.4%), and Toxocara spp
... Show MoreRenewable energy technology is growing fast especially photovoltaic (PV) system to move the conventional electricity generation and distribution towards smart grid. However, similar to monthly electricity bill, the PV energy producers can only monitor their energy PV generation once a month. Any malfuntion in PV system components may reduce the performance of the system without notice. Thus, developing a real-time monitoring system of PV production is very crucial for early detection. In addition, electricity consumption is also important to be monitored more frequently to increase energy savings awareness among consumers. Hardware based Internet-of-Thing (IoT) monitoring and control system is widely used. However, the implementation of
... Show MoreThis study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were th
... Show MoreThe research deals with an important issue that many people are working on, namely the sanctification of the texts on which the timings of the time and the different conditions of the place took place. Do not live up to the ranks of perfection and perfection, and every effort has explanations according to the mind machine, which is not protected by infallibility from error. The great downfall is to put these intellectual efforts in the Bible without separating them from the Word of God. The situation and the place on the adherents of a religion and mixed with the trick of the average individual only to be subject to the words of the teachers of Sharia and docility.
Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm
... Show MoreBackground: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the
... Show More