ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.
The goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.
Data generated from modern applications and the internet in healthcare is extensive and rapidly expanding. Therefore, one of the significant success factors for any application is understanding and extracting meaningful information using digital analytics tools. These tools will positively impact the application's performance and handle the challenges that can be faced to create highly consistent, logical, and information-rich summaries. This paper contains three main objectives: First, it provides several analytics methodologies that help to analyze datasets and extract useful information from them as preprocessing steps in any classification model to determine the dataset characteristics. Also, this paper provides a comparative st
... Show MoreNew types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3 catalyst. The results showed that Re-Ni-Mo/ γ-Al2O3 have more activity in desulfurization than Ni-Mo//γ-Al2O3
... Show MoreMost researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.
Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t
... Show MoreNew types of hydrodesulfurization (HDS) catalyst Re-Ni-Mo/ γ-Al2O3 was prepared and tested separately with two prepared conventional HDS catalysts (Ni-Mo/ γ-Al2O3 and Co-Mo//γ-Al2O3) by using a pilot plant hydrotreatment unit. Activities of three prepared hydrodesulfurization catalysts were examined in hydrodesulfurization (HDS) of atmospheric gas oil at different temperatures 275 to 350 °C and LHSV 1 to 4 h-1, the reactions conducted under constant pressure 40 bar and H2/HC ratio 500 ml/ml .Moreover, the hydrogenation of aromatic (HAD) in gas oil has been studied. HDS was much improved by adding promoter Re to the Ni-Mo/Al2O3
... Show More Educational services in Iraq face many problems that have reduced the efficiency of the educational process, as a result of the difficult conditions experienced by educational services in Iraq. This led to the accumulation of these problems and their exacerbation significantly over the years, as there was no fundamental solution to these problems. The study proposes a planning method for managing the educational system in Iraq, especially for the primary and secondary levels, where these negative phenomena are very prominent, especially the deficit in school buildings and the phenomenon of overcrowding in classrooms. &am
... Show MoreThe current research aims to identify the level of parental treatment methods tolerance, hostility, strictness, and warmth, as well as the level of self-efficacy among middle school students. Moreover, it aims to identify the correlation relationship between the variables of parental treatment methods and self-efficacy among middle school students. The research sample included (150) middle school students. For achieving the objectives of the current research, the researchers adopted a scale of parental treatment methods prepared by (Zughair, 2006), and a scale of self-efficacy prepared by (Youssef, 2016), which were applied in their final form to the research sample. The research reached the following results: parents use a low-level hos
... Show MoreBackground: A successful endodontic treatment is aimed at the sterilization of the entire pulp space. The use of extracts from Rhamnus prinoides as a novel irrigating material for root canal has not been studied . Hence, the antimicrobial efficacy of the alcoholic extract of Rhamnus prinoides as an irrigation material against E. faecalis was evaluated in comparison with the 2.5% sodium hypochlorite (NaOCL) solution used for root canals of permanent teeth. Methods: A total of 30 single-rooted human permanent teeth were thoroughly cleaned, shaped, and disinfected. Then, each tooth was subjected to a two-week infection with Enterococcus faecalis at 37 °C . Afterward, the samples were divided into three groups (10 teeth per group): 0.9
... Show More