Objective: To assess of Science Teachers' Awareness towards Communicable Diseases Control in Baghdad City
Primary Schools
Methodology: A descriptive study was conducted, included (100) primary school, (50) in Al-Rassafa sector, and
(50) in Al-Karkh sector, from March 5th 2012 to March 15th 2013, to assess of science teachers' awareness
towards communicable diseases control. A cluster sample of (100) Science teachers (males and females) were
selected, as one teacher from each school. A questionnaire format was used for data collection. The validity of
questionnaire was estimated through a penal of experts related to the field of study, and its reliability was
estimated through a pilot study conducted in (20) schools (
Objective(s): To measure serum C-reactive protein (CRP) titer as a predictive diagnosis of acute hepatitis C virus (HCV)
infection.
Methodology: Two hundred and ten patients with acute HCV infection and 234 apparently healthy individuals as
control group were enrolled in this study in Baghdad medical city (Teaching Laboratories). The patents include
74(35.2%) females and 136 (64.8%) males with mean age (27±16.5) years. The control group includes 114 (48.7%)
females and 120 (51.3%) males with mean age (26±5.8) years. Blood samples were collected from out patients from
Alfadul in Baghdad city. Sera were separated and stored at 20 0
C. The diagnosis of acute HCV infection was based on
detection of HC Ag and anti- H
sensor sampling rate (SSR) may be an effective and crucial field in networked control systems. Changing sensor sampling period after designing the networked control system is a critical matter for the stability of the system. In this article, a wireless networked control system with multi-rate sensor sampling is proposed to control the temperature of a multi-zone greenhouse. Here, a behavior based Mamdany fuzzy system is used in three approaches, first is to design the fuzzy temperature controller, second is to design a fuzzy gain selector and third is to design a fuzzy error handler. The main approach of the control system design is to control the input gain of the fuzzy temperature controller depending on the cur
... Show MoreBubbled slabs can be exposed to damage or deterioration during its life. Therefore, the solution for strengthening must be provided. For the simulation of this case, the analysis of finite elements was carried out using ABAQUS 2017 software on six simply supported specimens, during which five are voided with 88 bubbles, and the other is solid. The slab specimens with symmetric boundary conditions were of dimensions 3200/570/150 mm. The solid slab and one bubbled slab are deemed references. Each of the other slabs was exposed to; (1) service charge, then unloaded (2) external prestressing and (3) loading to collapse under two line load. The external strengthening was applied using prestressed wire with four approaches, wh
... Show MoreTrip generation is the first phase in the travel forecasting process. It involves the estimation of the
total number of trips entering or leaving a parcel of land per time period (usually on a daily basis);
as a function of the socioeconomic, locational, and land-use characteristics of the parcel.
The objective of this study is to develop statistical models to predict trips production volumes for a
proper target year. Non-motorized trips are considered in the modeling process. Traditional method
to forecast the trip generation volume according to trip rate, based on family type is proposed in
this study. Families are classified by three characteristics of population social class, income, and
number of vehicle ownersh
Transient three-dimensional natural convection heat transfer due to the influences of heating from one side of an enclosure filled with a saturated porous media, whereas the opposite side is maintained at a constant cold temperature, and the other four sides are adiabatic, were investigated in the present work experimentally. Silica sand was used as a porous media saturated with distilled water filled in a cubic enclosure heated from the side,using six electrical controlled heaters, at constant temperatures of (60, 70, 80, 90, and 100oC). The inverse side cooled at a constant temperature of (24oC) using an aluminum heat exchanger, consisted of 15 channels feeded with constant temperature water. Eighty thermocouples were used to control t
... Show More