Background: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit after the first visit
monthly for three successive months. For the purpose of
comparison (30) thirty volunteers admitted to this study as
control having same age range. The (160) patients were
categorized into two groups.
Group (A) includes (70) patients with ischemic heart
disease with complications like pulmonary oedema,
myocardial infarction, recent admission to coronary care
unit because of recurrent severs chest pain. Group (B)
includes (90) patients with ischemic heart disease without
any of the above complications. Myocardial performance
index is done by using the four chambers view and pulse
wave and curser along the mitral inflow of the blood jet.
Results: Assessment of left ventricular function by using
the myocardial performance index in group A was more
significant than using the ejection fraction in comparison to
the control group (P value 0.02, 0.03 respectively) the same
was found in group B in comparison to control group (P
value 0.01; 0.05 respectively).
Conclusion The myocardial performance index (MPI) in
the control groups was 0.44-0.36 MS indicating that its
range is very narrow in the control group, The (MPI) in the
two groups of patients was high in comparisons with
control group
The research discusses the obstacles that faced the Iraqi strategic performance in achieving sustainable development after the election of the first Iraqi government in 2005 and the most important strategies to overcome these obstacles.
Objective(s): To measure the level of job satisfaction and job performance of nurses and to find out
the association between participants' socio-demographic characteristic of nurse and their job
satisfaction and job performance.
Methodology: A descriptive analytic study design was carried out to measure the nurses' level of job
satisfaction and job performance in Al-Suwaira general hospital and to find out the association between
nurses and their socio-demographic characteristic. The study was started from March 5th, 2017 to
September 31th, 2017. The sample was Non - probability (purposive) sample of (100) nurses were
selected according to the study that are actual working in nursing department in Al-Suwaira General<
Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t
... Show MoreThis paper aims to investigate the flexural behavior of reinforced concrete beams considering fire resistance by adding Lightweight Expanded Clay Aggregates (LECA) to the concrete mix as partial coarse aggregate replacement. LECA is a type of porous clay with a uniform pore structure with fine, closed cells and hard, tightly sintered skin. The experimental work comprised four reinforced self-compacted concrete beams. All the specimens were identical in their geometrical layout of 1600×240×200 mm, reinforcement details, and support condition (simply supported). For all the beams, the main reinforcement was provided by two bars, each having a diameter of 12 mm, while a bar of 6 mm diameter was employed for the top and shear reinforc
... Show MoreBackground: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center
... Show MoreA simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was
... Show More