Background: Ejection fraction have been used frequently
for assessment of the left ventricular function, but can be
associated with errors in which myocardial performance
index have been used as another parameter to measure the
left ventricular function.
Objective: selecting another echocardiography parameter
for the assessment of myocardial in function instead of the
ejection fraction.
Methods: 160 patients referred to the echocardiogram unit
from the period december 2007 to august 2008 requesting
assessment of left ventricular function. After clinical
examination, routine blood tests; chest x-ray and
electrocardiographic recording have been completed. All
patients informed to come for this unit after the first visit
monthly for three successive months. For the purpose of
comparison (30) thirty volunteers admitted to this study as
control having same age range. The (160) patients were
categorized into two groups.
Group (A) includes (70) patients with ischemic heart
disease with complications like pulmonary oedema,
myocardial infarction, recent admission to coronary care
unit because of recurrent severs chest pain. Group (B)
includes (90) patients with ischemic heart disease without
any of the above complications. Myocardial performance
index is done by using the four chambers view and pulse
wave and curser along the mitral inflow of the blood jet.
Results: Assessment of left ventricular function by using
the myocardial performance index in group A was more
significant than using the ejection fraction in comparison to
the control group (P value 0.02, 0.03 respectively) the same
was found in group B in comparison to control group (P
value 0.01; 0.05 respectively).
Conclusion The myocardial performance index (MPI) in
the control groups was 0.44-0.36 MS indicating that its
range is very narrow in the control group, The (MPI) in the
two groups of patients was high in comparisons with
control group
Background: Imprelon® Biostar foils are new alternative tray material that has become increasingly popular because oftheir several advantages. Also, (Duran®) is another type of Biostar foils which is used in splint therapy. This study assessed some mechanical properties of these two types Biostar sheets in comparison with some types of acrylic resins used for construction of trays and splints. Materials and Methods: A total of 150 specimens were prepared, 30 specimens for each test, 10 for each group material in order to assess some mechanical properties of the Imprelon® Biostar foil (dimension stability, surface roughness and shear bond strength of Imprelon® materialto zinc oxide impression material) and compare them to that of the oth
... Show MoreDuring the last quarter century, many changes have taken place in the tanks industry and also in the materials that used in its production، while concrete is the most suitable material where concrete tanks has the benefits of strength, long service life and cost effectiveness. So, it is necessary improvement the
conventional concrete in order to adapt the severe environment requirements and as a result high
performance concrete (HPC) was used. It is not fundamentally different from the concrete used in the past, although it usually contains fly ash, ground granulated blast furnace slag and silica fume, as well as
superplasticizer. So, the content of cementitious material is high and the water/cement ratio is low. In this
stu
The present study aims at empirically investigating the effect of vocabulary learning strategies on Iraqi intermediate school students’vocabulary performance and reading comprehension. The population of the present study includes all the 1st year male students of Al-Wark’a intermediate school of Al-Risafa 1/ General Directorate of Education for the first course of the academic year (2015-2016). To achieve the aim of the study ,a pre-test and post-test after (5) weeks of experiment are administrated .The sample of the present study consists of (100) subjects :(50) students as an experimental group and other (50) students as a control group . The subj
... Show MoreAbstract
Objectives: The study aims to: (1) Find out the relationship among participants’ age, body mass index (BMI), and Health Belief Model (HBM) related to colorectal examinations among graduate students. (2) Investigate the differences in Health Belief Model constructs between the groups of age, gender, marital status, and education level among graduate students.
Methodology: A descriptive correlational study design which conducted in the College of Fine Arts – University of Baghdad. A convenience sample of 80 graduate students were included in this study. The data were collected by using a self-reported questionnaire which consisted of two parts (I) socio-demographic characteristics (II) Colorectal Cancer Screening Beliefs
This study seeks to address the impact of marketing knowledge dimensions (product, price, promotion, distribution) on the organizational performance in relation to a number of variables which are (efficiency, effectiveness, market share, customer satisfaction), and seeks to reveal the role of marketing knowledge in organizational performance.
In order to achieve the objective of the study the researcher has adopted a hypothetical model that reflects the logical relationships between the variables of the study. In order to reveal the nature of these relationships, several hypotheses have been presented as tentative solutions and this study seeks to verify the validity of these hypotheses.
... Show Morefacing economic units operating in the environment sector of the Iraqi
industrial many pressures in its seeking to measure and evaluate its performance because of variables, today's corporate environment, as the case which makes looking for a methodology can be adopted to evaluate its performance with a more holistic, rather than being limited to traditional measures that are no longer enough to keep pace with rapid changes in today's corporate environment, which requires that measures of performance are derived from the strategy of unity and commensurate with the specificity of the environment in Iraq. Try searching discussion Ttormwhrat and performance measurement systems to suit the business strategies and directions of change
... Show MoreIn this paper, a simulation of the electrical performance for Pentacene-based top-contact bottom-gate (TCBG) Organic Field-Effect Transistors (OFET) model with Polymethyl methacrylate (PMMA) and silicon nitride (Si3N4) as gate dielectrics was studied. The effects of gate dielectrics thickness on the device performance were investigated. The thickness of the two gate dielectric materials was in the range of 100-200nm to maintain a large current density and stable performance. MATLAB simulation demonstrated for model simulation results in terms of output and transfer characteristics for drain current and the transconductance. The layer thickness of 200nm may result in gate leakage current points to the requirement of optimizing the t
... Show MoreBackground: Knowing the indications for a cesarean section will help to have a better understanding of this common obstetrical procedure and prepare for the high level of care management that it entails. Aims of the study: The goal of this study was to determine the factors that influence caesarean section indications among women who visited AL-Dewaniya Maternity and Pediatric Hospital, as well as the relationship between caesarean section women's indications and socio-demographic data. Methodology: A descriptive cross-sectional study design is conducted for the period of December 26th 2020 to June 1st 2021 at Al Dewaniya Maternity and Pediatric Hospital. The validity of the questionnaire is determined through a panel of experts and reliabi
... Show MoreThe existing study aimed to assess four soil moisture sensors’ capacitive (WH51 and SKU: S EN0193) and resistive (Yl69 and IC Station) abilities, which are affordable and medium-priced for their accuracy in six common soil types in the central region of Iraq. The readings’ calibration for the soil moisture sensor devices continued through two gravimetric methods. The first depended on the protocols’ database, while the second was the traditional calibration method. The second method recorded the lowest analysis error compared with the first. The moderate-cost sensor WH51 showed the lowest standard error (SE), MAD , and RMSE and the highest R² in both methods. The performance accuracy of WH51 was close to readings shown by the manufac
... Show More