Preferred Language
Articles
/
jkmc-159
Role of Multi-Detector CT Angiography in Assesmente of Athrosclerotic Coronary Artery Disease
...Show More Authors

Background:  Imaging has a critical role in the diagnosis and evaluation of cardiac diseases, beginning with chest radiography and fluoro-scopy and progressing to coronary angio-graphy, echocardiography, nuclear medicine and recently  multidetector computed tomo-graphy (MDCT) as well as magnetic resonance (MR) imaging

Objective: To highlight the role of Multi-detector CT in the evaluation of coronary artery disease and its importance of being noninvasive diagnostic technique.

Methods: A cross sectional study for 20 patients. Patients were asked to fast 6 hours prior to the examination and the patients with heart rates above 65 beats per minute were given cardio-selective beta-blocker and for heart rate above 75 (up to 85) beat/min, the best systole phase was used for reconstructing our images

Results: for Evaluation of native coronary arteries, the CTCA showed significant lesions (occlusion or >60 % stenosis) in the native arteries of 13 patients and insignificant lesions in 7 patients.      

Evaluation of CABG (8 arterial grafts); for (LIMA) graft, 83% were patented,   and 17% were narrowed and 100 % of (radial graft) were   patent. For Venous Grafts the study included 10 venous grafts; 70 % were patent, 20% were narrowed and 10 % were totally occluded.

Conclusion: The multi-slice CTCA is now a clinically reliable noninvasive tool that allows the evaluation of the native coronary arteries, the bypass grafts, coronary stents.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research & Development
Predictive Value of Spectral Waveform Indices; Intimal Medial Thickness and Lumen Diameter of Carotid Artery in Iraqi Diabetic and Hypertensive Patients
...Show More Authors

Background: Diabetes and hypertension are related to cardiovascular risk factors and are possible to detect development of atherosclerosis in cardiovascular system, were can predict their effect and measurement by ultrasound and Doppler study. These risk factors included increased intima-media thickness, resistive index (RI) and pulsatility index (PI) of the right common carotid arteries. Method: We studied 20 patients with diabetes and hypertension, and 20 patients with diabetes only, were examine right carotid arteries for these two groups. In this sample we studied the Lumen diameter of the Rt. carotid arteries, Intima – media thickness (IMT), peak systolic velocity, end diastolic velocity, and Pulsatility index, Resistance index were

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Apr 04 2024
Journal Name
The International Tinnitus Journal
Efficacy of Sars-Cov-2 Vaccines on Severity of Coronavirus Disease in Iraq.
...Show More Authors

Vaccination against novel Coronavirus (SARS-CoV-2) become highly recommended. In Iraq, three vaccines are available. They are Pfizer-Biontech, Oxford-AstraZenica, and Sino harm vaccines. A cross-sectional retrospective study was performed to a total of 2399 individual who are vaccinated with one of the available vaccines. People who are infected with Covid-19 before and/or after vaccination of either studied SARS-CoV-2 vaccines were also involved in this study (1175 case). Signs and symptoms have been reported for each of confirmed positive cases of Coronavirus disease. Statistical data analyses were applied to reveal the effect of different SARS-CoV-2 vaccines on the incidence of novel coronavirus disease among Iraqi population. Also, the

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Determination the concentration for uranium in phosphrous fertilizers by using nuclear track detector CR-39
...Show More Authors

The aim of this research was to study the concentrations of Uranium in the phosphorus fertilizers using Nuclear track detector (CR-39). Our present investigation is based on the study of 10 types samples for different kinds of phosphorus fertilizers which were available in the local market Some of them were Iraqi made and the others from different countries like, (Iran, Italy, Holland, Lebanon and Jordan) .. The result obtained shows that the Uranium concentration in phosphorus fertilizers samples varies from (3.59ppm) to(2.59ppm). Based on the radioactive concentration of Uranium in the samples all the results obtained between(3.59ppm) in the Iraqi super phosphate to (2.59ppm) in the mixture Iraqi phosphate fertilizer are withi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Radon concentration measurement in soil for some northen Iraqi's regions by using CR-39 detector
...Show More Authors

Concentrations of radon were measured in this study for twenty-four samples of soil distributed in six locations on the north part of Iraq. The radon concentrations in soil samples measured by using alpha-emitters registration that emits from Radon (222Rn) in (CR-39) track detector. The concentrations values were calculated by a comparison with standard samples. The results shows that the radon gas concentrations in Darbandikhan City varies from (16.60-34.04 Bq/m3), Halabja City (16.51-23.32 Bq/m3), Al Sulaimaniya City (17.61-32.25 Bq/m3), Koisnjaq City (22.04-35.65 Bq/m3), Shaqlaua City (21.10-29.10 Bq/m3) and Erbil City (22.30-34.63 Bq/m3). The average radon gas concentration in Al Sulaimaniya and Erbil governorate are (22.30 Bq/m3)

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
A Multi-variables Multi -sites Model for Forecasting Hydrological Data Series
...Show More Authors

A multivariate multisite hydrological data forecasting model was derived and checked using a case study. The philosophy is to use simultaneously the cross-variable correlations, cross-site correlations and the time lag correlations. The case study is of two variables, three sites, the variables are the monthly rainfall and evaporation; the sites are Sulaimania, Dokan, and Darbandikhan.. The model form is similar to the first order auto regressive model, but in matrices form. A matrix for the different relative correlations mentioned above and another for their relative residuals were derived and used as the model parameters. A mathematical filter was used for both matrices to obtain the elements. The application of this model indicates i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 17 2019
Journal Name
Energy Procedia
Irradiation of the thin films of MnS with fast neutrons and the possibility of using the new characteristics in optical detector
...Show More Authors

The optical detectors which had been used in medical applications, and especially in radioactive treatments, need to be modified studied for the effects of radiations on them. This study included preparation of the MnS thin films in a way that vacuum thermal evaporation process at room temperature 27°C with thickness (400+-10nm) nm and a sedimentation rate of 0.39nm/sec on glass floors. The thin films prepared as a detector and had to be treated with neutron irradiation to examine the results gained from this process. The results decay X-ray (XRD) showed that all the prepared thin films have a multi-crystalline structure with the dominance of the direction (111), the two samples were irradiated with a neutron irradiation source (241Am-9Be)

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Journal Of Communicable Diseases
The Relation between RT-PCR and Chest CT Scan Sensitivity as Tools in the Diagnosis of COVID-19 Patients in Al-Najaf Province, Iraq
...Show More Authors

The typical test for diagnosis of severe acute respiratory syndrome coronavirus 2 is a reverse transcription-polymerase chain reaction (RT-PCR) technique, but the chest CT scan might play a complementary role at the first detection of Coronavirus Disease 2019 (COVID-19) pneumonia. Objectives: To determine the sensitivity of CT scan on patients with COVID-19 in Al-Najaf, Iraq, and to compare the accuracy of CT scan with that of RT-PCR technique. Material and Method: This is a prospective study. The patients suspicious of having COVID-19 infection and respiratory symptoms were registered. All patients were diagnosed by RT-PCR and chest CT. Diagnostic performance of CT was intended using RT-PCR as the reference sta

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 07 2020
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect of Vertical Irregularity in Multi-Storied Building under Seismic Loading
...Show More Authors

Publication Date
Wed Jul 01 2020
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect of Vertical Irregularity in Multi-Storied Building under Seismic Loading
...Show More Authors

Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Crestal Bone Resorption around Dental Implants in Flapped and Flapless Surgical Techniques Depending on Cone Beam CT Scan (Comparative Study)
...Show More Authors

Background: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref