Preferred Language
Articles
/
jkmc-159
Role of Multi-Detector CT Angiography in Assesmente of Athrosclerotic Coronary Artery Disease
...Show More Authors

Background:  Imaging has a critical role in the diagnosis and evaluation of cardiac diseases, beginning with chest radiography and fluoro-scopy and progressing to coronary angio-graphy, echocardiography, nuclear medicine and recently  multidetector computed tomo-graphy (MDCT) as well as magnetic resonance (MR) imaging

Objective: To highlight the role of Multi-detector CT in the evaluation of coronary artery disease and its importance of being noninvasive diagnostic technique.

Methods: A cross sectional study for 20 patients. Patients were asked to fast 6 hours prior to the examination and the patients with heart rates above 65 beats per minute were given cardio-selective beta-blocker and for heart rate above 75 (up to 85) beat/min, the best systole phase was used for reconstructing our images

Results: for Evaluation of native coronary arteries, the CTCA showed significant lesions (occlusion or >60 % stenosis) in the native arteries of 13 patients and insignificant lesions in 7 patients.      

Evaluation of CABG (8 arterial grafts); for (LIMA) graft, 83% were patented,   and 17% were narrowed and 100 % of (radial graft) were   patent. For Venous Grafts the study included 10 venous grafts; 70 % were patent, 20% were narrowed and 10 % were totally occluded.

Conclusion: The multi-slice CTCA is now a clinically reliable noninvasive tool that allows the evaluation of the native coronary arteries, the bypass grafts, coronary stents.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 01 2017
Journal Name
Nano Hybrids And Composites
Photodetection of Near and Middle IR Lasers by f-MWCNTs/Polythiophen Nanocomposite Detector
...Show More Authors

The combination of carbon nanotubes (CNT) and conducting polymers offers an attractive route for the production of novel compounds that can be used in a variety of applications such as sensors, actuators, and molecular scale electronic devices. In this work, functionalized multiwall carbon nanotubes (f-MWCNTs) were added in different load ratios (3 wt%, 5 wt% and 10 wt%) to thiophen (PTh) polymer to procedure PTh/CNTs nanocomposite and deposited on porous silicon substrate by electropolarization. Photoconductive detectors were fabricated using PTh/f-MWCNTs matrix to work in the near region and middle IR regions. These detectors were illuminated by semiconductor laser diode wavelength of 808(nm) and Nd-YAG laser of wavelength 1064 (n

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
A study of the Zn:Sn mixing ratio effect on the gas detector properties
...Show More Authors

Semiconductor-based metal oxide gas detector of five mixed from zinc chloride Z and tin chloride S salts Z:S ratio 0, 25, 50, 75 and 100% were fabricated on glass substrate by a spray pyrolysis technique. With thickness were about 0.2 ±0.05 μm using water soluble as precursors at a glass substrate temperature 500 ºC±5, 0.05 M, and their gas sensing properties toward CH4, LPG and H2S gas at different concentration (10, 100, 1000 ppm) in air were investigated at room temperature which related with the petroleum refining industry.
Furthermore structural and morphology properties were scrutinize. Results shows that the mixing ratio affect the composition of formative oxides were (ZnO, Zn2SnO4, Zn2SnO4+ZnSnO3, ZnSnO3, SnO2) ratios ment

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Journal Of Medicine And Life
Effect and benefit of percutaneous coronary intervention in chronic total occlusion on ventricular repolarization: QT correction and dispersion
...Show More Authors

ST segment, T wave changes, QT interval changes, and QTc dispersion are among the parameters used to diagnose ischemic heart disease. The increase in the QT dispersion can be caused by myocardial ischemia, among other heart diseases, whereas cardiac diseases such as coronary artery disease (CAD) can be diagnosed by observing an abnormally high QTc dispersion. This study aimed to evaluate the variations in the QTc dispersion (depolarization and repolarization) of surface electrocardiography as a result of percutaneous coronary intervention (PCI) in patients with chronic total occlusion. This study took place in the Iraqi Center for Heart Disease from October 2020 to February 2021. 110 patients who suffered from chronic occlusion of t

... Show More
View Publication
Scopus (13)
Crossref (6)
Scopus Crossref
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Cystatin (C) and its correlation to ischemic heart disease
...Show More Authors

Background: Cystatin C is recently considered to be a good predictor of cardiovascular morbidity and mortality in patients with coronary artery disease (CAD)Objectives: Correlation between cystatin and ischemic heart disease.Methods :One hundred forty patients (140) with ischemic heart disease admitted to thin study at Baghdad teaching hospital from the period June. 2011 to Jan. 2012. Those patients was categorized into three groups.Group (A): patients with ischemic heart failure.Group (B): Patients with myocardial infarction.Group (C) patients with unstable angina.All these groups were in comparison to fifty (50) healthy controls. Fasting serum citation (C) were measured in all patients and control in addition to all other routine inves

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Iraqi Journal Of Science
Diagnoses System of Varicose Disease
...Show More Authors

The diagnoses system of varicose disease has a good level of performance due to the complexity and uniqueness in patterns of vein of the leg. In addition, the patterns of vein are internal of the body, and its features are hard to duplicate, this reason make this method not easy to fake, and thus make it contains of a good features for varicose disease diagnoses. The proposed system used more than one type of algorithms to produce diagnoses system of varicose disease with high accuracy, in addition, this multi-algorithm technique based on veins as a factor to recognize varicose infection. The obtained results indicate that the design of varicose diagnoses system by applying multi- algorithms (Naïve Bayes and Back-Propagation) produced new

... Show More
Publication Date
Thu Apr 04 2024
Journal Name
The International Tinnitus Journal
Efficacy of Sars-Cov-2 Vaccines on Severity of Coronavirus Disease in Iraq.
...Show More Authors

Vaccination against novel Coronavirus (SARS-CoV-2) become highly recommended. In Iraq, three vaccines are available. They are Pfizer-Biontech, Oxford-AstraZenica, and Sino harm vaccines. A cross-sectional retrospective study was performed to a total of 2399 individual who are vaccinated with one of the available vaccines. People who are infected with Covid-19 before and/or after vaccination of either studied SARS-CoV-2 vaccines were also involved in this study (1175 case). Signs and symptoms have been reported for each of confirmed positive cases of Coronavirus disease. Statistical data analyses were applied to reveal the effect of different SARS-CoV-2 vaccines on the incidence of novel coronavirus disease among Iraqi population. Also, the

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Microchemical Journal
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

Scopus (24)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Determination the concentrations of radon gas and exhalation rate in some phosphate fertilizer using CR-39 track detector
...Show More Authors

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Microchemical Journal
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

View Publication Preview PDF
Scopus (24)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Wed Apr 25 2012
Journal Name
Journal Of Chromatographic Science
Direct Acetylation and Determination of Chlorophenols in Aqueous Samples by Gas Chromatography Coupled with an Electron-Capture Detector
...Show More Authors

A method was developed that offers a rapid, simple and accurate technique for the determination of chlorophenols at trace levels in aqueous samples with very limited volumes of organic solvents. These compounds were acetylated, then preliminarily extracted with n-hexane. The enriched chlorophenols were directly analyzed using gas chromatography with an electron-capture detector. The detection limits were in the range of 0.001–0.005 mg/L, except for 2-chlorophenol, which was always above 0.013 mg/L. Relative standard deviation for the spiked water samples ranged from 2.2 to 6.1%, while relative recoveries were in the range of 67.1 to 101.3%.

View Publication
Scopus (15)
Crossref (11)
Scopus Clarivate Crossref