Environmental Control Systems form one of the integral tasks of the designer, resulting from his/her acquaintance with the nature of sites and the way they are deployed to achieve modern space entity which is witnessing significant development in the field of interior design.Good deployment of these systems offer us, as designers, high potential and several varied solutions to configure internal spaces characterised as a fertile field of study and knowledge.The research problem was identified in the marginalisation of the importance of Environmental Control Systems as an important designing factor to achieve integrated design. The research problem was demonstrated in Chapter One, along with defining the objectives and formulating the research hypotheses.Chapter Two contained the research theoretical framework, which consists of a review of overall design trends and options when addressing Environmental Control Systems, by studying the most important influential factors of these systems, followed by key indicators derived from the theoretical framework which were, then, utilised in subsequent research procedures. In Chapter Three comes the stage of identifying the research methodology, the research community and the research sample, represented by two samples, and collecting information about them. The research tool was developed through what is construed from the theoretical framework.Chapter Four represented analysis of the content of selected research sample and results of the research were demonstrated, and, in light of these results, the research came out with findings which identified and explained the main differences resulting from deploying the best processors for Heating and Cooling Systems and, therefore, the most important design proposals and recommendations were identified to reach approved design decisions and utilising them to acquire a design product which achieves its objective
The aim of the research to measure the correlation relationship between modern manufacturing systems and process design and measure the effect by adopting the regression; the research consists of two main variables, which are modern manufacturing systems and process design; it was applied in the production lines of the General Company for Construction Industries, There is a sample of managers, engineers, technicians, administrators, and some workers were selected to fill the special questionnaire with (70) forms which distributed and (65) were approved suitable for use, For data analysis the correlation coefficient was adopted to measure the relationship and regression analysis to find out the effect, Using (SPSS), So the first h
... Show MoreThe present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials. Good agreement between the average theoretical and measured cooli
... Show MoreIn this research the effect of cooling rate and mold type on mechanical properties of the eutectic
and hypoeutectic (Al-Si) alloys has been studied. The alloys used in this research work were (Al- 12.6%Si
alloy) and (Al- 7%Si alloy).The two alloys have been melted and poured in two types of molds with
different cooling rates. One of them was a sand mold and the other was metal mold. Mechanical tests
(hardness, tensile test and impact test) were carried out on the specimens. Also the metallographic
examination was performed.
It has been found that the values of hardness for the alloys(Al-12.6%Si and Al-7%Si) which poured in
metal mold is greater than the values of hardness for the same alloy when it poured in a heated
The traffic congestion caused by the increase in the number of vehicles in the cities as a result of the increase in the population and the density of construction requires the provision of appropriate infrastructure and the provision of transport systems and logistics services that meet the needs of the population to meet the many challenges now and in the future by introducing various modes of transport , In accordance with integrated plans such as the use of (pedestrian friendly environments, bicycles and their own paths, light rail, metro, express bus, as well as public transport buses and others), through the development of Projects High-level roads, such as the annual and major roads, etc., and integrated with the urban planning of
... Show MoreThe topic of the research on the Observatory of the Walls on Jurisprudential Matters in the Hanafi Fiqh, by Imam San’a Allah bin Ali bin Khalil Al-Ala’iyya Wai al-Naqshbandi, al-Rumi, who died in 1137 AH, which includes seven chapters, the first section of it concerning division and related matters, and the second section in the adaptation It is the apportionment of benefits in common objects, the third section, which pertains to lines, surfaces, and bodies, the fourth section, which concerns the inclined wall and certification, and the fifth section, which concerns the provisions of the walls and its claims, and the sixth section, which concerns the door of roads and doors, the opening of the skylight, the sails of the wing, the can
... Show MoreThe speed of skills has become linked to modern methods of individual and group play, and each of them has begun to serve the other tactically. Through the follow-up of the researchers, they noticed that there is a significant weakness in the speed of performance and slowness in mental preparation, which plays a major role in understanding mental readiness, which is linked to the speed of making decisions during the game, as well as the weakness of the physical speed of the female players, which in turn has an impact on the skill performance of the players of the Iraqi clubs, which are the main supporter of the national team. The study aimed to identify the effect of interactive speed training on the performance of some skills among
... Show MoreObjective: To find out the association between psychological domain of Quality of life with study variable
(demographic &reproductive).
Methodology: A descriptive Analytical study was conduct on Non-probability (purposive sample)of (200) women
who have suffering from spontaneous abortion in maternity unit from four hospitals which include Al-Elwyia
maternity teaching hospital, and Baghdad teaching hospital at Al-Russafa sector. Al –karekh maternity hospital
and Al-Yarmook teaching hospital at Al-karekh sector. A questionnaire was used as a tool of data collection for the
period of February 3rd 2013 to April 26th 2013 and consisted of four parts, including demographic, reproductive
characteristics, and psycholog
The weather of Iraq has longer summer season compared with other countries. The ambient temperature during this season reaches over 50 OC which makes the evaporative cooling system suitable for this climate. In present work, the two-stage evaporative cooling system is studied. The first stage is indirect evaporative cooling (IEC) represented by two heat exchangers with the groundwater flow rate (5 L/min). The second stage is direct evaporative cooling (DEC) which represents three pads with groundwater flow rates of (4.5 L/min). The experimental work was conducted in July, August, September, and October in Baghdad. Results showed that overall evaporative efficiency of the system (two coils with three pads each
... Show MoreA numerical investigation is adopted for two dimensional thermal analysis of rocket thrust chamber wall (RL10), employing finite difference model with iterative scheme (implemented under relaxation factor of 0.9 for convergence) to compute temperature distribution within thrust chamber wall (which is composed of Nickel and Copper layers). The analysis is conducted for different boundary conditions: only convection boundary conditions then combined radiation, convection boundary conditions also for different aspect ratio (AR) of cooling channel. The results show that Utilizing cooling channels of high aspect ratio leads to decrease in temperature variation across thrust chamber wall, while no effects on heat transferred to the
... Show MoreIn this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.
An experimental study was carried out to estimate the performance of cooling system, where som
... Show More