Environmental Control Systems form one of the integral tasks of the designer, resulting from his/her acquaintance with the nature of sites and the way they are deployed to achieve modern space entity which is witnessing significant development in the field of interior design.Good deployment of these systems offer us, as designers, high potential and several varied solutions to configure internal spaces characterised as a fertile field of study and knowledge.The research problem was identified in the marginalisation of the importance of Environmental Control Systems as an important designing factor to achieve integrated design. The research problem was demonstrated in Chapter One, along with defining the objectives and formulating the research hypotheses.Chapter Two contained the research theoretical framework, which consists of a review of overall design trends and options when addressing Environmental Control Systems, by studying the most important influential factors of these systems, followed by key indicators derived from the theoretical framework which were, then, utilised in subsequent research procedures. In Chapter Three comes the stage of identifying the research methodology, the research community and the research sample, represented by two samples, and collecting information about them. The research tool was developed through what is construed from the theoretical framework.Chapter Four represented analysis of the content of selected research sample and results of the research were demonstrated, and, in light of these results, the research came out with findings which identified and explained the main differences resulting from deploying the best processors for Heating and Cooling Systems and, therefore, the most important design proposals and recommendations were identified to reach approved design decisions and utilising them to acquire a design product which achieves its objective
Steady conjugate natural convection heat transfers in a two-dimensional enclosure filled with fluid saturated porous medium is studied numerically. The two vertical boundaries of the enclosure are kept isothermally at same temperature, the horizontal upper wall is adiabatic, and the horizontal lower wall is partially heated. The Darcy extended Brinkman Forcheimer model is used as the momentum equation and Ansys Fluent software is utilized to solve the governing equations. Rayleigh number (1.38 ≤ Ra ≤ 2.32), Darcy number (3.9 * 10-8), the ratio of conjugate wall thickness to its height (0.025 ≤ W ≤ 0.1), heater length to the bottom wall ratio (1/4 ≤ ≤ 3/4) and inclination angle (0°, 30° and 60°) are the main consid
... Show MoreAn experimental and numerical investigation of the effect of using two types of nanofluids with suspending of (Al2O3 and CuO) nanoparticles in deionized water with a volume fraction of (0.1% vol.), in addition to use three types of fin plate configurations of (smooth, perforated, and dimple plate) to study the heat transfer enhancement characteristics of commercial fin plate heat sink for cooling computer processing unit. All experimental tests under simulated conditions by using heat flux heater element with input power range of (5, 16, 35, 70, and 100 W). The experimental parameters calculated are such as water and nanofluid as coolant with Reynolds number of (7000, 8000, 9400 and 11300); the air
... Show MoreObjectives: To assess the woman satisfaction with nursing care during labor.
Methodology: A descriptive analytic study about conducted for a purposive (non probability) sample of one hundred labor women interview validity and reliability of questionnaire are determined through panel of experts and pilot study. Descriptive and inferential statistical procedures were used to analyze the data, which collected by using interview technique.
Results: The study sample indicated that in general the women were satisfied in nursing care that provided during labor.
Recommendations: The study recommended educational tra
... Show MoreHeat transfer performance of two horizontal parallel plates subjected to discrete heating from the upper plate is studied and analyzed under the condition of different gap size between the heating elements with water as the working fluid. The investigation includes the variation of Reynolds number and the heat flux along with the position of the heating elements to discover the effect of different boundary conditions on the gap size variation. Results show that gap size between the heating elements has a crucial impact on the heat transfer process inside the channel, when the gap size increased a remarkable enhancement is achieved. This result is also confirmed with the investigated range of Reynolds number and the heating value. Results al
... Show MoreBackground: Knowing the indications for a cesarean section will help to have a better understanding of this common obstetrical procedure and prepare for the high level of care management that it entails. Aims of the study: The goal of this study was to determine the factors that influence caesarean section indications among women who visited AL-Dewaniya Maternity and Pediatric Hospital, as well as the relationship between caesarean section women's indications and socio-demographic data. Methodology: A descriptive cross-sectional study design is conducted for the period of December 26th 2020 to June 1st 2021 at Al Dewaniya Maternity and Pediatric Hospital. The validity of the questionnaire is determined through a panel of experts and reliabi
... Show MoreThe aim of this scientific paper is to highlight the effective role of women working in economic development, especially those working in the entrepreneurial sector, which we see as encouraging at the macro-economic level and at the personal level, by highlighting their potential to help them enter the private labour market, value them and empower their role in the economic arena in order to win this bet to become productive and effective workers at all levels.
Through this paper, we will try to highlight the role of Algerian women's contribution to economic development through access to the world of entrepreneurship, and we will also try to find statistics on their success levels at the local and interna
... Show MoreConventional cooling systems are major energy consumers in hot climates, directly contributing to increased carbon emissions and placing a significant strain on Iraq's national electricity grid. This study aims to explore and evaluate clean and sustainable alternatives to conventional systems. The methodology is based on a comparative analysis of various cooling technologies, including mechanical, absorption, adsorption, drying, and hybrid systems, using key performance indicators such as the coefficient of performance (COP), energy consumption, carbon emissions, and system cooling capacity. The results show that innovative solar cooling technologies offer superior operational effi
The varied thermal conductivity (insulation) of silica aerogel with heating for different pH has been investigated, it has been depended on ambient pressure drying method in the preparing silica aerogel samples, also six different pH of samples (1, 2, 3, 7, 8 and 9) were treated under five degree of heating with (50,100,150,200 and 250) ᴼC. This technique is important to test the carry-outs hydrophobic silica to temperature without high-quality material changes in the basic characteristics. The hot-wire technique is used in this work to examine the thermal conductivity, Fourier Transform Infrared Spectroscopy (FTIR) depended to characterize the bonds and their artificial by heating. Resu
... Show More