Green buildings are considered more efficient than traditional buildings due to the incorporated techniques and the multidisciplinary specializations required to comply with their specifications, in addition to the advanced commissioning, which undergoes before handing over the buildings to the owners to ensure requirements conformance. As a result, the appropriate selection of a project delivery system acts as the essential factor that affects the performance of the project. This research aims at building a system that helps to select the best method to implement green buildings. Through studying the recent research approaches in project delivery systems, the factors that affect the selection of the optimal implementation method for green buildings have been identified; expert interviews have been done to study and analyze the main influential factors that affect the selection of the best method for implementing green buildings. The results of interviews indicate that the main influential factors are as follows: The occurrence of economic crises in the country, availability of financial capacity for the contractor and the owner, the lack of previous experience in similar projects, hiring an incompetent contractor, differences between design drawings among all disciplines, and providing qualified contractors, subcontractors, suppliers and craftsmen with sufficient qualifications early in the project. Depending on these main factors, a software system is built to choose the best delivery system for green building projects. This research encourages future works to focus on the quality and performance of green buildings and lays out the foundation for academic researchers to explore new techniques for evaluating the project delivery systems as well as supporting the decision-makers to choose the best.
The aim of the research is to measure the relationship and effect of the application of total production maintenance TPM in the operational strategy, as it is considered one of the most important strategies for the process of restoring production losses because of inefficient equipment. Competitive edge in the global market by upgrading the operational strategies of OS in the application of TPM in those institutions that apply both H-OS-oriented and P-OS-oriented strategies where the strategy has been identified as a critical success factor. The aim of this study is to attempt to consider the application of comprehensive productive maintenance in industrial establishments
The study's objective is to find out the difference between the scholar of the research sample in awareness Green nanotechnology on the scaleas a whole and in each of its fields. The research depended of (136) specimen mem and women scholars of the fourth stage scholars / Department of Chemistry at the College of Education for Pure Sciences / Ibn Al-Haytham in Iraq for (2022-2023 AD) for the morning and evening studies, (65%) of the scientific community, It was picked at random with relation to the research instrument. it was a measure of awareness of green nanotechnology of (40) items, distributed in three areas (cognitive, skillful, emotional), and its validity and reliability were verified. Data analysis was completed for utilizing the s
... Show MoreIn the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the rang
In Australia, most of the existing buildings were designed before the release of the Australian standard for earthquake actions in 2007. Therefore, many existing buildings in Australia lack adequate seismic design, and their seismic performance must be assessed. The recent earthquake that struck Mansfield, Victoria near Melbourne elevated the need to produce fragility curves for existing reinforced concrete (RC) buildings in Australia. Fragility curves are frequently utilized to assess buildings’ seismic performance and it is defined as the demand probability surpassing capacity at a given intensity level. Numerous factors can influence the results of the fragility assessment of RC buildings. Among the most important factors that can affe
... Show MoreThe Contemporary Business Environment is Surrounded by many quick and continues variable and changes which has an effect on the economic units. These variables and changes like the high competition which need many tools to help them to continue and achieve The critical success. So to achieve this they have many competitive strategies like cost leadership strategy, differentiation strategy and focus strategy.
Budget is regarded one of main tools to execute objectives polices and programs of the economic units, beside show how the economic units had execute the available economic resources.
Activity based on budgeting is regarded one of the modern technique in the m
... Show Moreإن استخدام النظم الالكترونية في القطاع المصرفي وبالخصوص نظام مقاصة الصكوك الالكترونية (ACH) في عمليات التحويل الالكتروني للاموال بين المصارف تتضمن تحويلات مالية عالية القيمة بين المصارف المشاركة بهذا النظام, وان اي خلل قد يحدث بالنظام يؤدي الى حالات تلاعب في مقاصة الصكوك الالكترونية في المصارف المشاركة وبالتالي حدوث عملية اختلاس, ومن هذا المنطلق تبرز مشكلة البحث في اهمية توافر برنامج تدقيق مقترح ياخ
... Show MoreAmong the different passive techniques heat pipe heat exchanger (HPHE) seems to be the most effective one for energy saving in heating ventilation and air conditioning system (HVAC). The applications for nanofluids with high conductivity are favorable to increase the thermal performance in HPHE. Even though the nanofluid has the higher heat conduction coefficient that dispels more heat theoretically but the higher concentration will make clustering .Clustering is a problem that must be solved before nanofluids can be considered for long-term practical uses. Results showed that the maximum value of relative power is 0.13 mW at nanofluid compared with other concentrations due to the low density of nanofluid at this concentration. For highe
... Show MoreIn this paper the variable structure control theory is utilized to derive a discontinuous controller to the magnetic levitation system. The magnetic levitation system model is considered uncertain, which subjected to the uncertainty in system parameters, also it is open-loop unstable and strongly nonlinear. The proposed variable structure control to magnetic levitation system is proved, and the area of attraction is determined. Additionally, the chattering, which induced due to the discontinuity in control law, is attenuated by using a non-smooth approximate. With this approximation the resulted controller is a continuous variable structure controller with a determined steady state error according to the selected control
... Show MoreIn this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(