Preferred Language
Articles
/
OhfzyZIBVTCNdQwCI8DJ
The radio anatomical arrangement of nerve roots at L3 level in cauda equina sac is it affected by diseases?
...Show More Authors

An observational study to discover the common conditions affecting the lumbosacral region that may affect lumbosacral position and tension. All the patients, underwent MRI exaamination (magnetic resonance imaging) in the supine position, were examined by the same consultant radiologist. The article was revised by the institutional ethical approval committee. The position of the nerve roots was observed, and the number of nerve roots was calculated anterior to a line passing between the mid-transvers process of L3(third lumbar vertebra). The number of nerve roots ahead of this line was calculated by the radiologist at the level of the right intervertebral foramen and at the left one. This procedure was applied to the normal group, and 5 common pathological diseases were repeated including single-level lumbar disc prolapse, multiple-disc prolapse, multiple bulge, spinal stenosis and spondylolisthesis (at the level of L45 (fourth to fifth lumbar vertebrae) or L5S1 (fifth lumbar to first sacral vertebrae) being outside the study area, i.e., L3). We noticed significant difference in the number of the nerve roots between the cases with herniated discs, spinal stenosis, and spondylolisthesis with the normal group and the significance was in ascending increment in significance being the highest in cases with spondylolisthesis, and even in the groups of other pathologies which are statistically not significant, we noticed that the significance is proportional to the severity of the disease being the least in single level cases (p 0.427), to be more significant on cases with multiple prolapses(p 0.319) to be more in cases with multiple bulges to start to be statistically significant in herniated, higher significance in cases with spinal stenosis to be the highest in cases with spondylolisthesis.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jan 01 2015
Journal Name
Iraqi Journal Of Science
Improved Rijndael Algorithm by Encryption S-Box Using NTRU Algorithm
...Show More Authors

With the wide developments of computer applications and networks, the security of information has high attention in our common fields of life. The most important issues is how to control and prevent unauthorized access to secure information, therefore this paper presents a combination of two efficient encryption algorithms to satisfy the purpose of information security by adding a new level of encryption in Rijndael-AES algorithm. This paper presents a proposed Rijndael encryption and decryption process with NTRU algorithm, Rijndael algorithm is widely accepted due to its strong encryption, and complex processing as well as its resistance to brute force attack. The proposed modifications are implemented by encryption and decryption Rijndael

... Show More
Publication Date
Mon Oct 28 2013
Journal Name
Desalination And Water Treatment
Groundwater protection from cadmium contamination by zeolite permeable reactive barrier
...Show More Authors

This work studies the performance of zeolite permeable reactive barrier in removing cadmium from a contaminated shallow aquifer. Batch tests have been performed to characterize the equilibrium sorption properties of the zeolite in cadmium-containing aqueous solutions. A 1D numerical finite difference model has been developed to describe pollutant transport within groundwater taking pollutant sorption on the permeable reactive barrier (PRB), which is performed by Langmuir equation, into account. Numerical results show that the PRB starts to saturate after a period of time (~120 h) due to reduction of the retardation factor, indicating a decrease in the percentage of zeolite functionality. However, a reasonable agreement between model predict

... Show More
Scopus (38)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Sun Nov 26 2017
Journal Name
Journal Of Engineering
Compression Index and Compression Ratio Prediction by Artificial Neural Networks
...Show More Authors

Information about soil consolidation is essential in geotechnical design. Because of the time and expense involved in performing consolidation tests, equations are required to estimate compression index from soil index properties. Although many empirical equations concerning soil properties have been proposed, such equations may not be appropriate for local situations. The aim of this study is to investigate the consolidation and physical properties of the cohesive soil. Artificial Neural Network (ANN) has been adapted in this investigation to predict the compression index and compression ratio using basic index properties. One hundred and ninety five consolidation results for soils tested at different construction sites

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 28 2021
Journal Name
2021 2nd Information Technology To Enhance E-learning And Other Application (it-ela)
Pedestrian and Objects Detection by Using Learning Complexity-Aware Cascades
...Show More Authors

View Publication Preview PDF
Scopus (8)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Desalination And Water Treatment
Reducing endotoxin from dialysis water by using different disinfection processes
...Show More Authors

View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Telkomnika (telecommunication Computing Electronics And Control)
Dorsal hand veins features extraction and recognition by correlation coefficient
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
MINIATURE TWO-FINGERED ROBOT HAND DRIVEN BY MUSCLE WIRES ACTUATORS
...Show More Authors

In this research, a modified artificial hand with direct control has been designed using electrical artificial muscle wires that receive direct sensory impulses through human hand instead of using the mechanical action to open and close this artificial hand. Each finger is designed as a chain and its movements achieved through the conventional arrangement control of the electrical muscles wires. The results indicate that it is possible to design an artificial hand using electrical muscle wire for control it with high accuracy.

View Publication Preview PDF
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
An Investigation into Heat Transfer Enhancement by Using Oscillating Fins
...Show More Authors

The present work describes numerical and experimental investigation of the heat transfer characteristics in a plate-fin, having built-in piezoelectric actuator mounted on the base plate (substrate). The geometrical configuration considered in the present work is representative of a single element of the plate-fin and triple fins. Air is taken as the working fluid. A performance data for a single rectangular fin and triple fins are provided for different frequency levels (5, 30 and
50HZ) , different input power (5,10,20,30,40 and 50W) and different inlet velocity (0.5, 1, 2, 3, 4, 5 and 6m/s) for the single rectangular fin and triple fins with and without oscillation. The investigation was also performed with different geometrical fin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Energy Generation from Static Water Head Developed By Forward Osmosis
...Show More Authors

In this work, the possibility of utilizing osmosis phenomenon to produce energy as a type of the renewable energy using Thin Film Composite Ultra Low Pressure membrane TFC-ULP was studied. Where by forward osmosis water passes through the membrane toward the concentrated brine solution, this will lead to raise the head of the high brine solution. This developed static head may be used to produce energy. The aim of the present work is to study the static head developed and the flux on the high brine water solution side when using forward and reverse osmosis membranes for an initial concentration range from 35-300 g/l for each type of membrane used at room temperature and pressure conditions, and finally calculating the maximum possible po

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 06 2023
Journal Name
Environmental Monitoring And Assessment
Copper metal elimination from polluted soil by electro-kinetic technique
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref