Background: The bond strength of the root canal sealers to dentin seems to be a very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate the shear bond strength of four different obturation systems using push-out test. Materials and methods: Forty straight palatal roots of the maxillary first molars teeth were used in this study, these roots were instrumented using crown down technique and ProTaper system, instrumentation were done with copious irrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilled water, roots were randomly divided into four groups according to the obturation system (ten teeth for each group): Group I: AH26 sealer and lateral condensation technique, Group II: AH26 sealer and single cone obturation technique, Group III: AH26 sealer and thermafil obturation technique and Group IV: RealSeal SE sealer and lateral condensation technique, the roots then stored in moist environment at 37°C for one week The roots were embedded in clear acrylic resin and each root sectioned into three levels apical, middle and cervical. The measurement of each section was taken to prepare the supporting jig for the sections and the punch used in pushout test, the bond strength was measured using computerized universal testing machine each section fixed in the machine so that the load applied from apical to cervical direction at 0.5mm/min. speed and the computer drew curve to show the higher bond force before dislodgment of the filling material. These forces were divided by the surface area to obtain the bond strength in MPa. Results: Statistical analysis was performed and the result showed avery highly significant differences between the four obturation systems at each level and there were non significant differences between all level apical, middle and cervical within each obturation system except a significant difference found between cervical and apical level in single cone obturation system. Conclusion: This study showed that the shear bond strength of AH26 sealer was higher than RealSeal SE sealer when the same obturation technique was used. The shear bond strength was affected by the obturation technique and lateral condensation technique showed higher bond strength than thermafil and single cone obturation technique when the same type of sealer was used and the bond strength was not or little affected by the tooth level
Background: The aim of this study was to determine phototoxic effect of visible blue light on anaerobic periodontal pathogens namely Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis. Materials and methods: Strains of Aggregatibacter actinomycetemcomitans and Porphyromonas gingivalis were isolated from pockets of systemically healthy patients aged between 35-55 years old with pocket depths of 5-6 mm, the bacteria cultured on special blood Agar plates solid media, then subjected to visible blue light emitted from commercially available light cure devise (LED curing light); that emits blue light (400-500nm) of 1000mw energy at different periods of time exposures, then the CFU of each plate was measured by direct colony count
... Show MoreThe aim of the present study is to formulate floating effervescent microsponge tablet of the narrow absorption window drug, Baclofen (BFN) for controlling drug release and thereby decrease the side effect of the drug. The microsponges of BFN were prepared by non-aqueous emulsion solvent diffusion method (oil in oil emulsion method). The effects of drug: polymer ratio, stirring time and type of Eudragit polymer on the physical characteristics of microsponges were investigated and characterized for production yield, loading efficiency, particle size, surface morphology, and in vitro drug release from microsponges. The selected microsponge formula was incorporated into the floating effervescent gastro-retentive tablet. The prepared fl
... Show MoreBackground: To evaluate the effect of antierosive agents (10% Nano-Hydroxyapatite (NHA), 10% Casein Phophopeptide-Amorphous Calcium Phosphate (CPP-ACP), and combination of 10% NHA and 10% CPP-ACP) on loss of minerals from enamel surface of permanent teeth treated with antierosive agents when exposed to an acidic beverage and investigate the morphological changes of treated enamel surface after demineralization with cola based beverage under Scanning Electron Microscope (SEM). Materials and Methods: Sixty maxillary first premolars were randomly divided into four groups, 15 teeth for each group. Group I treated with 10% NHA, Group II treated with 10% CPP-ACP, Group III treated with 10% NHA and 10% CPP-ACP, and Group IV did not treat with any
... Show MoreAcontaminated ophthalmic solutions represent a potential cause of avoidable ocular infection. This study aimed to determine the magnitude and pattern of microbial contamination of eye drops in out patient at the department of ophthalmology, at Baghdad national hospital, Iraq. Fifty four vials from the out patient clinic were obtained for microbial examination after an average use of 2 weeks. The dropper tip and the residual eye drop were examined for contamination. The specimens were cultured, the number of colonies counted, the organisms identified. Eight (15%) out of 54 analyzed vials were contaminated , most bacteria identi
... Show MoreLeiomyosarcoma (smooth muscle tumor) is a rare type of a malignant neoplasm of smooth
muscle. It is a resistant cancer, generally not very responsive to chemotherapy, radiationand surgery.The
aim of this study was to evaluate photodynamic therapy (PDT) as a possible basis for treatment using
(650 nm)diode laser with methyleneblue (MB) as a photosensitizer on leiomyosarcoma (LMS)cell line
(L20B) in vitro. The cytotoxic effects of 650nm diode laser 0.052 W/cm2 (power density) at different
exposure time (10, 20, and 30 min) with methylene blue at different concentrations (0.01% ,0.1 % ,1%)
was investigated on LMS cell line (L20 B). The cytotoxic effect of laser was increased with increasing
irradiation time for a certai
Background: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa
... Show More
ABSTRACT Background: One of the major problems of all ceramic restorations is their probable fracture against the occlusal forces. The objective of this in vitro study was to evaluate the effect of two gingival finishing lines (90°shoulder and deep chamfer) on the fracture resistance of full contour CAD/CAM and heat press all-ceramic crowns. Materials and Methods: Thirty two maxillary first premolars were prepared to receive full contour CAD/CAM (zolid) and heat press (Cergo Kiss) ceramic crowns using a special paralleling device (Parallel-A-Prep). The teeth were divided into four groups according to the type of finishing line prepared. Each crown was cemented to its corresponding tooth using self-etch, self-adhesive dual cure resin ceme
... Show MoreBackground: Debonding and fracture of artificial teeth from denture bases are common clinical problem, bonding of artificial teeth to heat cure acrylic and high impact heat cure acrylic denture base materials with autoclave processing method is not well known. The aim of this study was to evaluate the effect of autoclave processing method on shear bond of artificial teeth to heat cure denture base material and high impact heat cure denture base material. Materials and methods: Heat polymerized (Vertex) and high impact acrylic (Vertex) acrylic resins were used. Teeth were processed to each of the denture base materials after the application of different surface treatments. The sample (which consist of artificial tooth attached to the dentur
... Show More