Preferred Language
Articles
/
6hcle44BVTCNdQwCUUl7
Design of a Hybrid Adaptive Controller for Series Elastic Actuators of Robots
...Show More Authors

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Journal Of Communications Software And Systems
Proactive Hybrid Half and Joint D2D Handover Scheme in Multi-access Mobile Edge Computing (MEC)
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Compare between result of analysis of variance after and before use analysis covariance to Split-blocks design
...Show More Authors

This research aims to study the important of the effect of analysis of covariance manner for one of important of design for multifactor experiments, which called split-blocks experiments design (SBED) to deal the problem of extended measurements for a covariate variable or independent variable (X) with data of response variable or dependent variable Y in agricultural experiments that contribute to mislead the result when analyze data of Y only. Although analysis of covariance with discussed in experiments with common deign, but it is not found information that it is discussed with split-Blocks experiments design (SBED) to get rid of the impact a covariance variable. As part application actual field experiment conducted, begun at

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Agricultural Engineering
The Effect of Design and the Accelerated Wear Test of Agricultural Nozzles on the Resulting Droplet Size
...Show More Authors
Abstract<p>The change in the size of the droplets during the pesticide application process could have a negative impact on the percentage of drift or the losses of pesticides to the environment. One of the factors that could affect the droplet size produced from a single nozzle is the internal design of the nozzle itself, in addition to the wear of the nozzle orifice as a result of the usage time. In this research, three types of nozzles with different internal designs were used (Turbo TeeJet (TT), Turbo TwinJet (TTj 6011003), and Drift Guard (DG 11003)). The nozzles were subjected to an accelerated wear test for one hundred hours, and different droplet size parameters (Dv 0.1, Dv 0.5, Dv 0.9), </p> ... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Electrochemical Science
Effect of Electrolysis Parameters on the Specific Surface Area of Nickel Powder: Optimization using Box-Behnken Design
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2011
Journal Name
Journal Of Economics And Administrative Sciences
Analysis of the composite variance of dissected splitting experiments carried out according to the Latin box design
...Show More Authors

In this research we present An idea of setting up same split plots experiments in many locations and many periods by Latin Square Design. This cases represents a modest contribution in area of design and analysis of experiments. we had written (theoretically)  the general plans, the mathematical models for these experiments, and finding the derivations of EMS for each component (source) of sources of variation of the analysis of variance tables which uses for the statistical analysis for these expirements

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
A Proposed Artificial Intelligence Algorithm for Assessing of Risk Priority for Medical Equipment in Iraqi Hospital
...Show More Authors

This paper presents a robust algorithm for the assessment of risk priority for medical equipment based on the calculation of static and dynamic risk factors and Kohnen Self Organization Maps (SOM). Four risk parameters have been calculated for 345 medical devices in two general hospitals in Baghdad. Static risk factor components (equipment function and physical risk) and dynamics risk components (maintenance requirements and risk points) have been calculated. These risk components are used as an input to the unsupervised Kohonen self organization maps. The accuracy of the network was found to be equal to 98% for the proposed system. We conclude that the proposed model gives fast and accurate assessment for risk priority and it works as p

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 08 2024
Journal Name
New Materials, Compounds And Applications
MOLECULAR MODELLING AND THEORETICAL DESIGN OF NOVEL NIRMATRELVIR DERIVATIVES AS SARS-COV-2 ENTRY INHIBITORS
...Show More Authors

The pandemic SARS-CoV-2 is highly transmittable with its proliferation among nations. This study aims to design and exploring the efficacy of novel nirmatrelvir derivatives as SARS entry inhibitors by adapting a molecular modeling approach combined with theoretical design. The study focuses on the preparation of these derivatives and understanding their effectiveness, with a special focus on their binding affinity to the S protein, which is pivotal for the virus’s access to the host cell. Considering molecular docking aspects in the scope of a study on nirmatrelvir derivatives and S protein, dynamics simulations with 25 nanoseconds of their binding are explored. The study shows that these derivatives might work as effective antivi

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at theMechanical Engineering Department at Baghdad University - College of Engineering. The work is one ofthe pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes thefirst part of the work; that is the design calculations, simulation and construction. It will be followed by asecond part that describes testing and calibration of the tunnel. The proposed wind tunnel has a testsection with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flowdisturbances in the test sec

... Show More
View Publication
Crossref (7)
Crossref
Publication Date
Tue Oct 13 2026
Journal Name
Journal Of Engineering
DESIGN, CONSTRUCTION AND TESTING OF LOW SPEED WIND TUNNEL WITH ITS MEASUREMENT AND INSPECTION DEVICES
...Show More Authors

A low speed open circuit wind tunnel has been designed, manufactured and constructed at the Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the first part of the work; that is the design calculations, simulation and construction. It will be followed by a second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70 m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow disturbances in the test section.

... Show More
View Publication
Publication Date
Sun Jun 30 2024
Journal Name
Wasit Journal For Pure Sciences
Design Polynomial IIR Digital Filters of the Integer Parameters Space Use to Compress Image Data
...Show More Authors

Polynomial IIR digital filters play a crucial role in the process of image data compression. The main purpose of designing polynomial IIR digital filters of the integer parameters space and introduce efficient filters to compress image data using a singular value decomposition algorithm. The proposed work is designed to break down the complex topic into bite-sized pieces of image data compression through the lens of compression image data using Infinite Impulse Response Filters. The frequency response of the filters is measured using a real signal with an automated panoramic measuring system developed in the virtual instrument environment. The analysis of the output signal showed that there are no limit cycles with a maximum radius

... Show More
View Publication
Crossref