Piezoelectric structures are nowadays used in many different applications. A better understanding of the influence of material properties and geometrical design on the performance of these structures helps to develop piezoelectric structures specifically designed for their application. Different equivalent circuits have been introduced in the literature to investigate the behaviour of piezoelectric transducers. The model parameters are usually determined from measurements covering the characteristic frequencies of the piezoelectric transducer. This article introduces an analytical technique for calculating the mechanical and electrical equivalent system parameters and characteristic frequencies based on material properties and geometry for a cantilever bimorph structure. The model is validated by measurements using a cantilever bimorph and fits the experimental results better than previous models. The model gives a full set of piezoelectric transducer parameters and is therefore well suited for further theoretical investigations of piezoelectric transducers for different applications. The results also show that even small manufacturing tolerances have a considerable effect on the system parameters and characteristic frequencies. This might lead to intolerable deviations, especially in dynamic applications and should be avoided by careful design and production.
The determination hardness in water raised to rivers caused several problem in the validity of the water used depends on where determination ions concentration calcium and magnesium in salts carbonate and sulfate , this possibility of separation between of these ions and the resulting impact on concentration and determination the degree of hardness water and appreciation between the insolvent water quality . It study the effect of the impact of concentration magnesium ion in determination the quality of the water has turned out to be Mg concentration more than 60% of the total content of hardness is borderline in hardness effect the determination. Adopted in this research determination the ions in two method titration by EDTA solution and
... Show MoreAbsorption properties (Attenuation coefficient, the percentage of the reflection, and the percentage of absorption) in x-band have been investigated in this paper for novolac – alumina- graphite mixture. Using novolac as the host material, the samples are prepared with alumina concentrations (5%,10%,15%,20%) and graphite concentrations (5%,10%) with thickness equal to 2.2mm .Network analyzer produced by HP-8510 was used in this work to measure the attenuation coefficient. The samples (3, 5) have good attenuation of wave with bandwidth of frequencies. The maximum of attenuation is -25dB at frequency 10.28GHZ in sample (3) which has concentrations (80%novolac,10%alumina,and 5% graphite) and -24 dB at frequency 10.56GHZ in sample (5) whic
... Show MoreThe current study included measuring the percent of protein in the extract of nematode Ascaridia galli that infect chickens, it was 1.157% and equivalent to 11.570 mg /L., as well as the amino acid analysis in the nematode A.galli by using a high-performance liquid chromatography technique (HPLC), as was detect five types for amino acids in this extract Leucine, Threonin, Serine, Methionine and Valine as the amount of these amino acids in the extract was as follows 132.973, 26.994, 10.453, 2.243 and 1.888 mg /L., respectively, and other amino acids which Glutamic, Histidine and Tyrosin did not exist in the nematode A.galli.
A simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec
... Show MoreDue to the urgent need to develop technologies for continuous glucose monitoring in diabetes individuals, poten tial research has been applied by invoking the microwave tech niques. Therefore, this work presents a novel technique based on a single port microwave circuit, antenna structure, based on Metamaterial (MTM) transmission line defected patch for sensing the blood glucose level in noninvasive process. For that, the proposed antenna is invoked to measure the blood glu cose through the field leakages penetrated to the human blood through the skin. The proposed sensor is constructed from a closed loop connected to an interdigital capacitor to magnify the electric field fringing at the patch center. The proposed an tenna sensor i
... Show MoreNumerical study is adapted to combine between piezoelectric fan as a turbulent air flow generator and perforated finned heat sinks. A single piezoelectric fan with different tip amplitudes placed eccentrically at the duct entrance. The problem of solid and perforated finned heat sinks is solved and analyzed numerically by using Ansys 17.2 fluent, and solving three dimensional energy and Navier–Stokes equations that set with RNG based k−ε scalable wall function turbulent model. Finite volume algorithm is used to solve both phases of solid and fluid. Calculations are done for three values of piezoelectric fan amplitudes 25 mm, 30 mm, and 40 mm, respectively. Results of this numerical study are compared with previous b
... Show MoreBackground: Anemia is a common finding in patients with renal failure disease and it is, primarily, due to reduced production of iron and erythropoietin. Therefore, the aim of current study was to evaluate the relationship between serum level of hepcidin 25, on the one hand, and levels of serum iron, total iron-binding capacity, serum erythropoietin and transferrin saturation% in Iraqi male patients undrgoning haemodialysis.. Methods: Serum from75 males in the end stage of hemodialysis, as group one, and 25 Iraqi healthy malecontrols, as group two, were recruited in this study. Results: Data from current study showed significant increase in hepcidin 25 and significant decrease in serum iron, total iron-binding capacity, transferrin saturati
... Show More
