Preferred Language
Articles
/
3BcLe44BVTCNdQwCe0mc
Analytical determination of characteristic frequencies and equivalent circuit parameters of a piezoelectric bimorph
...Show More Authors

Piezoelectric structures are nowadays used in many different applications. A better understanding of the influence of material properties and geometrical design on the performance of these structures helps to develop piezoelectric structures specifically designed for their application. Different equivalent circuits have been introduced in the literature to investigate the behaviour of piezoelectric transducers. The model parameters are usually determined from measurements covering the characteristic frequencies of the piezoelectric transducer. This article introduces an analytical technique for calculating the mechanical and electrical equivalent system parameters and characteristic frequencies based on material properties and geometry for a cantilever bimorph structure. The model is validated by measurements using a cantilever bimorph and fits the experimental results better than previous models. The model gives a full set of piezoelectric transducer parameters and is therefore well suited for further theoretical investigations of piezoelectric transducers for different applications. The results also show that even small manufacturing tolerances have a considerable effect on the system parameters and characteristic frequencies. This might lead to intolerable deviations, especially in dynamic applications and should be avoided by careful design and production.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
The effect of anode temperature on the Optical characteristic of Se films prepared by direct current planar magnetron sputtering
...Show More Authors

This work describes, selenium (Se) films were deposited on clean glass substrates by dc planar magnetron sputtering technique.The dependence of sputtering deposition rate of Se film deposited on pressure and DC power has been studied. The optimum argon pressure has range (4x10-1 -8x10-2 )mbar. The optical properties such as absorption coefficient (α) was determined using the absorbance and transmission measurement from UnicoUV-2102 PC spectrophotometer, at normal incidence of light in the wavelength range of 200-850 nm. And also we calculated optical constants(refractive index (n), dielectric constant (εi,r), and Extinction coefficient (κ) for selenium films.

View Publication Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
A Comparison between Methods of Laplace Estimators and the Robust Huber for Estimate parameters logistic regression model
...Show More Authors

The logistic regression model regarded as the important regression Models ,where of the most interesting subjects in recent studies due to taking character more advanced in the process of statistical analysis .                                                

The ordinary estimating methods is failed in dealing with data that consist of the presence of outlier values and hence on the absence of such that have undesirable effect on the result.    &nbs

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 28 2023
Journal Name
Journal Of Advanced Pharmaceutical Technology & Research
Development of a spectrophotometric analytical approach for the measurement of cefdinir in various pharmaceuticals
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 29 2023
Journal Name
International Journal Of Nonlinear Analysis And Applications (ijnaa)
Applying a suitable approximate-simulation technique of an epidemic model with random parameters
...Show More Authors

Because the Coronavirus epidemic spread in Iraq, the COVID-19 epidemic of people quarantined due to infection is our application in this work. The numerical simulation methods used in this research are more suitable than other analytical and numerical methods because they solve random systems. Since the Covid-19 epidemic system has random variables coefficients, these methods are used. Suitable numerical simulation methods have been applied to solve the COVID-19 epidemic model in Iraq. The analytical results of the Variation iteration method (VIM) are executed to compare the results. One numerical method which is the Finite difference method (FD) has been used to solve the Coronavirus model and for comparison purposes. The numerical simulat

... Show More
Publication Date
Tue Feb 01 2022
Journal Name
Civil Engineering Journal
Calibration of a New Concrete Damage Plasticity Theoretical Model Based on Experimental Parameters
...Show More Authors

The introduction of concrete damage plasticity material models has significantly improved the accuracy with which the concrete structural elements can be predicted in terms of their structural response. Research into this method's accuracy in analyzing complex concrete forms has been limited. A damage model combined with a plasticity model, based on continuum damage mechanics, is recommended for effectively predicting and simulating concrete behaviour. The damage parameters, such as compressive and tensile damages, can be defined to simulate concrete behavior in a damaged-plasticity model accurately. This research aims to propose an analytical model for assessing concrete compressive damage based on stiffness deterioration. The prop

... Show More
Scopus (29)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Determination of Molecular Weight and Viscosity of Irradiated Polystyrene
...Show More Authors

 

The varied applications of polystyrene in various fields of life led to examining the cause of radiation influence on some rheological behavior of commercial Polystyrene (PS) solution in the chloroform (CHCl3) solvent. Polystyrene grains shape samples were irradiated using the radioactive element Cesium- 137 with (9 µci) activity for 10, 20, and 30 minutes. The viscosity of the polymer solution depends on the concentration and size (i.e. molecular weight) of the dissolved polymer. Experimental data showed that the radiation dose affected the value of viscosity (shear, relative, specific, and reduced). The viscosity value significantly reduced at 10 min radiation dose and when increasing the dose, the viscosity value increased

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
Robust estimation of multiple linear regression parameters in the presence of a problem of heterogeneity of variance and outliers values
...Show More Authors

Often times, especially in practical applications, it is difficult to obtain data that is not tainted by a problem that may be related to the inconsistency of the variance of error or any other problem that impedes the use of the usual methods represented by the method of the ordinary least squares (OLS), To find the capabilities of the features of the multiple linear models, This is why many statisticians resort to the use of estimates by immune methods Especially with the presence of outliers, as well as the problem of error Variance instability, Two methods of horsepower were adopted, they are the robust weighted least square(RWLS)& the two-step robust weighted least square method(TSRWLS), and their performance was verifie

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 31 2020
Journal Name
Indian Journal Of Public Health Research & Development
A Comparative Study of Vitamin D Levels and Some Biochemical Parameters between Healthy and Breast Cancer in Iraqi Females.
...Show More Authors

Breast cancer is one of the most widespread cancers,depending on World Health Organization, cancer calculated for approximately 7.6 million incidences in 2008, whoever expected elevation in incidence is about 13.1 million in 2030. So that the current research investigates vitamin D role in the occurrence of this disease and explains if vitamin D has a positive effect on the incidence of disease, as well as measuring parathyroid hormone and estrogen levels. Three groups were included in this analysis: control healthy women, benign and malignant breast tumor women. All cases that were selected at the beginning of the disease diagnosis. According to statistical values vitamin D showed highly significant (P<0.001) decrease in benign (3.74±2.33

... Show More
Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Journal Of Biotechnology Research Center
Study the Effects of Methotrexate with and without Vitamin A on Some Biochemical and Histological Parameters in Male Rabbits
...Show More Authors

The present study aims to evaluate the effects of methotrexate (MTX) with and without vitamin A (Vit. A) on some biochemical parameters and histological structure in male rabbits liver. Twenty male rabbits weighing 1250-1480 gm were divided into four equal number groups. The first group was given 2 ml distilled water as control group. The second group was given MTX (20 mg/kg), the third group was given Vit. A (5000 IU), while the fourth group was given MTX (20 mg/kg) +Vit. A (5000 IU) in alternative days. Following four weeks of treatment, lipid profile total cholesterol (TC), triglycerides (TG), high-density lipoprotein (HDL), [low-density lipoprotein (LDL) and very low-density lipoprotein (VLDL)]; in addition to thyroid hormones tr

... Show More