Preferred Language
Articles
/
zxgRxpYBVTCNdQwC_4a7
Determination of zinc ions in drinking water distribution systems (PVC pipes) by spectrophotometric method
...Show More Authors

In this work, a method for the simultaneous spectrophotometric determination of zinc which was precipitated into deionized water that is in a commercial distribution systems PVC pipe, is proposed using UV-VIS Spectrophotometer. The method based on the reaction between the analytes Zn2+ and 2-carboxy-2-hyroxy-5-sulfoformazylbenze (Zincon) at an absorption maximum of 620nm at pH 9-10. This ligand is selective reagent. Since the complex is colored (blue), its stoichiometry can be established using visible spectrometry to measure the absorbance of solutions of known composition. The stoichiometry of the complex was determined by Job’s method and molar ratio method and found to be 1:2 (M: L). A series of synthetic solution containing different concentrations of zinc were used to check the prediction ability of the complexation. Water quality samples collected a 100cm PVC system of drinking water in three sizes from different country full with deionized water for different time.

Publication Date
Wed Mar 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrosorption of Hexavalent Chromium Ions by MnO2/Carbon Fiber Composite Electrode: Analysis and Optimization of the Process by Box-Behnken Design
...Show More Authors

A nano manganese dioxide (MnO2) was electrodeposited galvanostatically onto a carbon fiber (CF) surface using the simple method of anodic electrodeposition. The composite electrode was characterized by field emission scanning electron microscopy (FESEM), and X-ray diffraction (XRD). Very few studies investigated the efficiency of this electrode for heavy metals removal, especially chromium. The electrosorption properties of the nano MnO2/CF electrode were examined by removing Cr(VI) ions from aqueous solutions. NaCl concentration, pH, and cell voltage were studied and optimized using the Box-Behnken design (BDD) to investigate their effects and interactions on the electrosorption process. The results showed that the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Spectrophotometric Study of ?-Irradiated PM-355
...Show More Authors

The aim of the present work is concerned with the effect of ?-irradiation on PM-355 with absorbed dose of (30-160Mrad) range. This polymer is evaluated spectrophotometrically for use as high dose dosimeters. The absorption spectra of irradiated samples showed radiation induced absorption changes. There is an increment in absorption proportional with absorbed dose. This increment is attributed to interfaces traps which, are formed by irradiation. Calibration curve was drawn .The linear relation was found in calibration curve, and dosimeter range was determined from the linear part. The linearity in response curve suggested that PM-355 could be used as dosimeter within (30-160Mrad) rang. Energy gap shift was used as a second tool to determin

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Effect of Partial Drip Irrigation Methods on Soil Moisture and Water Potential Distribution, Growth Characteristics and Yield of Maize
...Show More Authors

A field experiment was conducted during the autumn of 2021 at the Agricultural Research Department station / Abu Ghraib to evaluate the soil moisture, water potential distribution, and growth factors of maize crops under alternating and constant partial drip irrigation methods. In the experiment, two irrigation systems were used, surface drip irrigation (DI) and subsurface irrigation (SD); under each irrigation system, five irrigation methods were: conventional irrigation (CI), and 75 and 50% of the amount of water of CI of each of the alternating partial irrigation APRI75 and APRI50 and the constant partial irrigation FPRI75 and FPRI50 respectively. The results showed that the water depth for conventional irrigation (C1) was 658.3

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Determination of Antibodies (IgG, IgM) against Toxoplasma gondii in Some Iraqi individuals by using ELISA technique
...Show More Authors

A total of 258 voluntary blood donors (males 101; females 157) in the age range of 18-52 yr among males and 18-55 yr among females were examined for Toxoplasma gondii antibodies (IgG), and (IgM) by immunological technique (Enzyme linked Immunosorbant Assay) during the period from March 2009 to April 2010. This study covered a wide range of factors including immunological, age ,sex , place of residence and symptoms that may have a possible relationship with toxoplasmosis. Results presented in this study showed clearly that 38 (14.7%) of individuals participated in this study having IgG Toxoplasma Ab, among those 10 samples (9.9%) were males and 28 samples (17.8%) were females. Moreover, we found the prevalence of IgM seropositivity in th

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography & Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Determination of paracetemol in pharmaceutical preparations samples by spectrophotometer using meta phenylenediamine as a chromogenic agent
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref
Publication Date
Tue Aug 20 2019
Journal Name
International Journal Of Drug Delivery Technology
Kinetic - Spectrophotometric Estimation of Tetracycline in Bulk and Pharmaceutical Forms
...Show More Authors

Simple and sensitive spectrophotometric method is described based on the coupling reaction of tetracycline hydrochloride(TC. HCl) with diazotized 4-aminopyridine in bulk and pharmaceutical forms. Colored azo dye formed during this reaction is measured at 433 nm as a function of time. Factors affecting the reaction yield were studied and the conditions were optimized. The kinetic study involves initial rate and fixed time (10 minutes) procedures for constructing the calibration graphs to determine the concentration of (TC. HCl). The graphs were linear for both methods in concentration range of 10.0 to 100.0 µg.mL-1. The recommended procedure was applied successfully in the determination of (TC. HCl) in itscommercial formulations.

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Feb 07 2024
Journal Name
Egyptian Journal Of Chemistry
Spectrophotometric Estimation of Methyldopa Drug in pure and pharmaceutical formulations
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Jun 02 2019
Journal Name
International Journal Of Drug Delivery Technology
Kinetic-spectrophotometric estimation of tetracycline in bulk and pharmaceutical forms
...Show More Authors

Simple and sensitive spectrophotometric method is described based on the coupling reaction of tetracycline hydrochloride (TC. HCl) with diazotized 4-aminopyridine in bulk and pharmaceutical forms. Colored azo dye formed during this reaction is measured at 433 nm as a function of time. Factors affecting the reaction yield were studied and the conditions were optimized. The kinetic study involves initial rate and fixed time (10 minutes) procedures for constructing the calibration graphs to determine the concentration of (TC. HCl). The graphs were linear for both methods in concentration range of 10.0 to 100.0 μg.mL-1. The recommended procedure was applied successfully in the determination of (TC. HCl) in its commercial formulations.

Scopus (3)
Scopus
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Determination Of Micro Amount Of Spironolactone In Some Of Pharmaceutical Preparate By Using a Molecular Luminescence Technique.
...Show More Authors

The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods

... Show More
View Publication Preview PDF
Crossref