Preferred Language
Articles
/
zheIYo8BVTCNdQwCN3Sc
A Comparative Study of the Right and Left Carotid Arteries in Relation to Age for Patients With Diabetes and Hypertension
...Show More Authors
Introduction:

Age, hypertension, and diabetes can cause significant alterations in arterial structure and function, including changes in lumen diameter (LD), intimal-medial thickness (IMT), flow velocities, and arterial compliance. These are also considered risk markers of atherosclerosis and cerebrovascular disease. A difference between right and left carotid artery blood flow and IMT has been reported by some researchers, and a difference in the incidence of nonlacunar stroke has been reported between the right and left brain hemispheres. The aim of this study was to determine whether there are differences between the right and left common carotid arteries and internal carotid arteries in patients with hypertension and diabetes for 2 age groups.

Methods:

We studied 250 patients with both diabetes and hypertension. Patients were divided into 2 age groups with the old age group being 56 to 75 years and the young age group 35 to 55 years. The bilateral common carotid and internal carotid arteries were evaluated with B-mode ultrasound and Doppler examinations. The LD and IMT were measured for both common carotid arteries, and spectral waveform parameters and indices were recorded for both internal carotid arteries.

Results:

The difference in LD between the left and right common carotid arteries for the old age group was 11.64% and for the young age group was 6.42%, with significant P values of <.05 for both age groups. The difference in IMT between the left and right common carotid arteries was 18.27% in the old age group compared with 15.38% in the young age group, with significant P values of <.05. There was a difference in peak systolic velocity between the left and right internal carotid arteries of 4.85% in the old age group which was not significant, compared with 14.28% in the young age group with a significant P value <.05, whereas the difference in end-diastolic velocity between the left and right internal carotid arteries was not significant for both age groups. Differences between the right and left internal carotid arteries for resistive index, pulsatility index, and pressure gradient were significant only in the young age group.

Conclusion:

We found significant differences between the right and left common carotid and internal carotid arteries in patients with diabetes and hypertension which were more prominent in the young age group. Values for common carotid IMT and LD were significantly higher in the left common carotid artery versus the right common carotid artery in both age groups. Differences between the 2 carotid sides may be attributed to anatomic variations in the common carotid artery origins which lead to differences in stress between the 2 sides.

Scopus Crossref
View Publication
Publication Date
Sat Feb 28 2015
Journal Name
Al-khwarizmi Engineering Journal
Stabilizing Gap of Pole Electric Arc Furnace Using Smart Hydraulic System
...Show More Authors

Abstract

Electric arc furnace applications in industry are related to position system of its pole, up and down of pole. The pole should be set the certain gap. These setting are needed to calibrate. It is done manually. In this research will proposed smart hydraulic to make this pole works as intelligent using proportional directional control valve. The output of this research will develop and improve the working of the electric arc furnace. This research requires study and design of the system to achieve the purpose and representation using Automation Studio software (AS), in addition to mathematically analyzed and where they were building a laboratory device similar to the design and conduct experiments to stud

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
Acta Polytechnica
COMPLEXITY REDUCTION OF CYCLOSTATIONARY SENSING TECHNIQUE USING IMPROVED HYBRID SENSING METHOD
...Show More Authors

In cognitive radio system, the spectrum sensing has a major challenge in needing a sensing method, which has a high detection capability with reduced complexity. In this paper, a low-cost hybrid spectrum sensing method with an optimized detection performance based on energy and cyclostationary detectors is proposed. The method is designed such that at high signal-to-noise ratio SNR values, energy detector is used alone to perform the detection. At low SNR values, cyclostationary detector with reduced complexity may be employed to support the accurate detection. The complexity reduction is done in two ways: through reducing the number of sensing samples used in the autocorrelation process in the time domain and through using the Slid

... Show More
View Publication
Scopus (9)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Nov 25 2024
Journal Name
Iraqi Journal For Computer Science And Matgematics
Posinormality of Operators Treated by Weyl's Theorem on Unbounded Hilbert Space
...Show More Authors

Hamiltonians, momentum operators, and other quantum-mechanical perceptible take the form of self-adjoint operators when understood in quantized physical schemes. Unbounded and self-adjoint recognition are required in the situation of positive measurements. The selection of the proper Hilbert space(s) and the selection of the self-adjoint extension must be made in order for this to operate. In this effort, we define a new extension positive measure depending on the measurable field of nonzero positive self-adjoint operator in unbounded Hilbert space of analytic functions of complex variables. Consequently, we define an extension norm in the same space. We show several new properties of the suggested operator and its adjoin operator. These pr

... Show More
Scopus Crossref
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Wool Dyes from Industrial Wastewater by Reverse Osmosis Process
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jan 10 2020
Journal Name
Fibers
CFRP Laminates Reinforcing Performance of Short-Span Wedge-Blocks Segmental Beams
...Show More Authors

Two of the main advantages of segmental construction are economics, as well as the rapid construction technique. One of the forms of segmental construction, for structural elements, is the segmental beams that built-in short sections, which referred to segments. This research aims to exhibit a new technique for the fabrication of short-span segmental beams from wedge-shaped concrete segments and carbon fiber reinforced polymers (CFRP) in laminate form. The experimental campaign included eight short-span segmental beams. In this study, two selected parameters were considered. These parameters are; the number of layers of CFRP laminates and the adhesive material that used to bond segments to each other, forming short-span segmental be

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Tue Mar 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical removal of copper from synthetic wastewater using rotating cylinder electrode
...Show More Authors

The performance of a batch undivided electrochemical reactor with a rotating cylinder electrode of woven-wire (60 mesh size), stainless steel 316, is examined for the removal of copper from synthetic solution of o.5 M sodium chloride containing 125 ppm at pH ≈ 3.5. The effect of total applied current, rotation speed on the figures of merit of the reactor is analyzed. For an applied current of 300 mA at 100 rpm, the copper concentration decreased from 125 to  mg l-1 after 60 min of electrolysis with a specific energy consumption of 1.75 kWh kg-1 and a normalized space velocity of 1.62 h-1. The change in concentration was higher when the total applied currents were increased because of the turbulence

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 30 2023
Journal Name
Pakistan Heart Journal
Evaluation of nurses Practice toward Children Safety Post Cardiac Catheterization Procedure
...Show More Authors

Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Engineering
Numerical Simulation of Natural Convection Heat Transfer from Interrupted Rectangular Fins
...Show More Authors

      Numerical simulations have been investigated to study the external free convective heat transfer from a vertically rectangular interrupted fin arrays. The continuity, Naver-Stockes and energy equations have been solved for steady-state, incompressible, two dimensional, laminar with Boussiuesq approximation by Fluent 15 software. The performance of interrupted fins was evaluated to gain the optimum ratio of interrupted length to fin length (

View Publication Preview PDF
Publication Date
Sun Jul 01 1990
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
AQUATIC INVERTEBRATE FAUNA OF AN UPLAND RESERVOIR SYSTEM, CO-WICKLOW, IRELAND
...Show More Authors

Littoral and benthic invertebrates from Roundwood Reservoir System were sampled. Oligochaetes and molluscs were the dominant organisms in the littoral and benthic areas Trichopterans and chironomids were the most abundant insect groups. Scuba diving samples reinforced that view. Other groups of macroinvertebrates were poorly represented. Vertical and horizontal hauls of zooplankton revealed that there were twelve species of zooplankton present. Daphnia hyalina Leydig and Bosmina coregoni Baird were the two dominant species.

View Publication Preview PDF
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Desalination of Highly Saline Water Using Direct Contact Membrane Distillation (DCMD)
...Show More Authors

In this work, laboratory experiments were carried out to verify direct contact membrane distillation system’s performance in highly saline water desalination. The study included the investigation of various operating conditions, like feed flow rate, temperature and concentration of NaCl solution and their impact on the permeation flux were discussed. 16 cm2 of a flat sheet membrane module with commercial poly-tetra-fluoroethylene (PTFE) membrane, which has 0.22 μm pore size, 96 µm thickness and 78% average porosity, was used. A high salt rejection factor was obtained greater than 99.9%, and the permeation flux up to 17.27 kg/m2.h was achieved at 65°C for hot feed side and 20°C for cold side stream.

View Publication Preview PDF
Crossref (6)
Crossref