Background: Preterm labor and related prematurity are predisposing factors that increase perinatal morbidity and mortality. Acute phase reactants are inflammatory markers which are positive and negative reactants explained by the reaction of reactants to the subclinical infection that are commonly associated with preterm labor. Objectives: To assess the role of acute phase reactants in pregnant women with preterm delivery. Patients and method: A case control study conducted in Gynecological Department of Baghdad Teaching Hospital from 1st February 2021 to 30th October 2021, on one hundred pregnant women with gestational age (28weeks - 36weeks+6days) who attended outpatient clinic; fifty pregnant women with established preterm labor as case group and fifty pregnant women with no signs and symptoms of preterm labor as control group. Data was collected using structured questionnaire included demographic features, and biochemical parameters (serum ferritin (ng/ml), albumin (gm/dl), fibrinogen (mg/dl), and calcium (mg/dl) . Results: Mean±SD serum ferritin in control group was (46.2 ± 16.2 ng/ml) while in case group (52.47 ± 11.6ng/ml) with significant difference between both groups (P=0.03), mean±SD serum albumin in control group (3.18 ± 0.31 ng/ml) while in case group (2.92 ± 0.39) with highly significant difference between both groups (P<0.001). Validity test of serum ferritin at cutoff ≥ 52.7 (ng/ml) in case group was as follows: Sensitivity (94%), specificity (90%), negative predictive value (94%), positive predictive value (90%) and the accuracy was (92%). The validity test of serum albumin at cutoff ≤ 3.06 (gm/dl) to detect the preterm labor as follows: Sensitivity (78%), specificity (86%), negative predictive value (78%), positive predictive value (83%) and the accuracy was (84%). Mean±SD serum fibrinogen in control group was (400.9 ± 38.1) while in case group was (410.7 ± 51.2) with no significant difference between both groups (P=0.1). Mean±SD serum calcium in control group was (8.1 ± 0.7) while in case group was (7.92 ± 0.5) with no significant difference between both groups (P=0.1). Conclusion: serum ferritin and albumin can be used in prediction of preterm labor in 3rd trimester.
The -multiple mixing ratios of γ-transitions from levels of populated in the are calculated in the present work by using the a2-ratio methods. We used the experimental coefficient (a2) for two γ-transitions from the same initial state, the statistical tensor, which is related to the a2-coefficient would be the same for the two transitions. This method was used in a previous work for pure transitions or which can be considered pure. In these cases the multiple mixing ratios for the second transition ( ) equal zero, but in our work we applied this method for mixed γ-transitions and then the multiple mixing ratio ( ) is known for one transition. Then we calculate the ( ) value and versareversa. The weight average of the -values calcu
... Show MoreThis study was carried out to evaluate the antioxidant activity of Iraqi sumac seeds (Rhus coriaria. L) (Anacardiaceae). Total phenolic compounds and flavoniods were determined in three different sumac seed extracts (SSE) (aqueous,ethanolic and methanolic extract). For extraction Antioxidant activity of SSE were evaluated by various antioxidant assays, including total antioxidant capacity, reducing power,by using 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical scavenging, nitric oxide scavenging, Hydroxyl radical scavenging, and metal ion chelating activities. These various antioxidant activities were compared with ascorbic acid as a standard antioxidant.The results showed that the three(SSE), contained large amounts of phenolic and flavonio
... Show MoreFunctionalized-multi wall carbon nanotubes (F-MWCNTs) and functionalized-single wall carbon nanotubes (F-SWCNTs) were well enhanced using CoO Nanoparticles. The sensor device consisted of a film of sensitive material (F-MWCNTs/CoONPs) and (F-SWCNTs/CoO NPs) deposited by drop- casting on an n-type porous silicon substrate. The two sensors perform high sensitivity to NO2 gas at room temperatures. The analysis indicated that the (F-MWCNTs/CoONPs) have a better performance than (F-SWCNTs/CoONPs). The F-SWCNTs/CoONPs gas sensor shows high sensitivity (19.1 %) at RT with response time 17 sec, while F-MWCNTs/CoONPs gas sensor show better sensitivity (39 %) at RT with response time 13 sec. The device shows a very reproducible sensor p
... Show MoreLet R be a commutative ring with non-zero identity element. For two fixed positive integers m and n. A right R-module M is called fully (m,n) -stable relative to ideal A of , if for each n-generated submodule of Mm and R-homomorphism . In this paper we give some characterization theorems and properties of fully (m,n) -stable modules relative to an ideal A of . which generalize the results of fully stable modules relative to an ideal A of R.
In this work, we calculate and analyze the photon emission from quark and anti-quark interaction during annihilation process using simple model depending on phenomenology of quantum chromodynamic theory (QCD). The parameters, which include the running strength coupling, temperature of the system and the critical temperature, carry information regarding photon emission and have a significant impact on the photons yield. The emission of photon from strange interaction with anti-strange is large sensitive to decreases or increases there running strength coupling. The photons emission increases with decreases running strength coupling and vice versa. We introduce the influence of critical temperature on the photon emission rate in o
... Show MoreNumerical simulations are carried out to assess the quality of the circular and square apodize apertures in observing extrasolar planets. The logarithmic scale of the normalized point spread function of these apertures showed sharp decline in the radial frequency components reaching to 10-36 and 10-34 respectively and demonstrating promising results. This decline is associated with an increase in the full width of the point spread function. A trade off must be done between this full width and the radial frequency components to overcome the problem of imaging extrasolar planets.
Mn2+ and Ce3+ Doped ZnS nanocrystals were prepared by a simple microwave irradiation method under mild condition. The starting materials for the synthesis of Mn2+ and Ce3+ Doped ZnS P nanocrystals were zinc acetate as zinc source, thioacetamide as a sulfur source, manganese chloride and Cerium chloride as manganese and cerium sources respectively (R & M Chemical) and ethylene glycol as a solvent. All chemicals were analytical grade products and used without further purification. The nanocrystals of Mn2+ and Ce3+ Doped ZnS P with cubic structure were characterized by X-ray powder diffraction (XRD), the morphology of the film is seen by field effect scanning electron microscopy (FESEM). The composition of the samples is analyzed by EDS. The s
... Show More