The poultry industry is developing continuously and rapidly, this development takes several trends in the poultry industry, such as searching for new alternatives feed additives. The research focused on finding new alternatives feed additives, among these alternatives is Synoptic, which used to maximize the benefit of the two important compounds (probiotics and prebiotics) as these two compounds are considered one of the most alternatives feed additives, which have been used a lot in poultry feeding to maximize the value of these compounds, they were combined into one compound called synbiotic. Several studies confirm that the synbiotic effect on the intestine morphology, which, the ratio villus height and villus: crypt ratio in the small intestinal significantly increased (p < 0.05). This explains the improvement in growth performance and nutritional efficiency in most of the research that has found that synoptic influences growth performance traits. Other important effect for add synbiotic on diets is increase the benefit microorganism in the intestine and increase the competition with pathogenic bacteria, this will reduce the pathogenic bacteria, also the benefit bacteria secrete inhibitor substrate effect on the pathogenic microorganism. The previous studies confirm that the synbiotic increase the immunity, improve the health performance and reduce the mortality. In this chapter, we will discuss more details about synoptic in poultry feeding in terms of its components, physiological mechanism in the body and its effect on productive performance and immunity.
This study carry’s out the correlation and the effect of two main variables, these variables are Job Satisfaction included six sub: wages - salaries and justice and yield, working conditions and services, pattern of supervision and the relationship with the manger, Relationship with colleagues, the content of the work and the variety of tasks, development and promotion opportunities available to an individual, and Organizational Performance included two sub variables: Efficiency, Effectiveness. This research was conducted using a questioner as a main tool, This questioner was distributed randomly to a research community composed of
... Show MoreThe aim of the research is to reveal the reality of teacher performance evaluation in the Sultanate of Oman in light of some global models. The study followed a qualitative descriptive research design. Seven forms of teacher formative and summative assessments were analyzed. Besides, an analytical template was developed, consisting of six areas related to the teaching performance of teachers. These included: lesson planning and preparation, learning environment, education, professional development, student academic, and community and parental partnership. The study reached a number of results; the most notable is the lack of change of forms for more than a decade despite the rapid development of the educational system in the sultanate in
... Show MoreIn this modern Internet era and the transition to IPv6, routing protocols must adjust to assist this transformation. RIPng, EIGRPv6 and OSPFv3 are the dominant IPv6 IGRP (Interior Gateway Routing Protocols). Selecting the best routing protocol among the available is a critical task, which depends upon the network requirement and performance parameters of different real time applications. The primary motivation of this paper is to estimate the performance of these protocols in real time applications. The evaluation is based on a number of criteria including: network convergence duration, Http Page Response Time, DB Query Response Time, IPv6 traffic dropped, video packet delay variation and video packet end to end de
... Show MoreThe research dealt with the risks of reinsurance and its impact on the financial performance of the National Insurance Company by focusing on reinsurance in the marine insurance branch. Negative impact on the financial performance of the NICs and the Marine Insurance Branch. The research sample resulted in a main hypothesis that reflects this relationship. Lee in the analysis of financial information reports National Insurance Company of the branch of marine insurance for the period of 2010 until 2017, and the use of (retention) for measuring the re-insurance operations index, and (insurance financial surplus rate) to measure financial performance. For the purpose of obtaining the results, a number of statistical methods were used accord
... Show MoreAn experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.
أستهدفت الدراسة اختبار أثر التوجه السوقي والتزام العاملين على أداء المنظمة المسوقة لخدمات النقل الجوي. حيث تم اختيار شركة الخطوط الجوية الملكية الأردنية كمجال تطبيقي.وقد اعتمدت الدراسة في قياس المتغيرات على مقاييس مختبرة وقد تأكد صحتها وثباتها لقياس المتغيرات في البيئة الحالية. وقد بينت نتائج التحليل الإحصائي الذي استخدمت فيه أساليب إحصائية مختلفة بالاستعانة ببرنامج SPSS))
The thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and
... Show MoreThis work is concerned with the design and performance evaluation of a shell and double concentric tubes heat exchanger using Solid Works and ANSY (Computational Fluid Dynamics).
Computational fluid dynamics technique which is a computer-based analysis is used to simulate the heat exchanger involving fluid flow, heat transfer. CFD resolve the entire heat exchanger in discrete elements to find: (1) the temperature gradients, (2) pressure distribution, and (3) velocity vectors. The RNG k-ε model of turbulence is used to determining the accurate results from CFD.
The heat exchanger design for this work consisted of a shell and eight double concentric tubes. The number of inlets are three and that of o
... Show MoreIn Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c
... Show MoreConstruction and operation of (2 m) parabolic solar dish for hot water application were illustrated. The heater was designed to supply hot water up to 100 oC using the clean solar thermal energy. The system includes the design and construction of solar tracking unit in order to increase system performance. Experimental test results, which obtained from clear and sunny day, refer to highly energy-conversion efficiency and promising a well-performed water heating system.