Preferred Language
Articles
/
yBgZGJUBVTCNdQwCCSWU
FREQUENCY OF LOW BIRTH WEIGHT AMONG NEONATES ADMITTEDTO THE NEONATAL INTENSIVE CARE UNIT
...Show More Authors

Publication Date
Thu Mar 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Low Carbon Steel in Sulfuric Acid Using Polyvinyl Alcohol
...Show More Authors

The inhibitive power of Polyvinyl Alcohol (PVA) was investigated toward the corrosion of carbon steel in 0.2N H2SO4 solution in the temperature range of 30-60˚C and PVA concentration range of 150-2000 ppm.

   The corrosion rate was measured using both the weight loss and the electrochemical techniques. The weight loss results showed that PVA could serve as a corrosion inhibitor but its inhibition power was found to be low for the corrosion of carbon steel in the acidic media. Electrochemical analysis of the corrosion process of carbon steel in an electrochemical corrosion cell was investigated using 3-Electrode corrosion cell. Polarization technique was used for carbon steel corrosion in 0.2N H

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Low Carbon Steel in Different HCl Concentrations by Phenythiourea
...Show More Authors

Phenylthiourea  (PHTU),was  tested  as  inhibitor for  the  corrosion  of  low  carbon  steel  in different  HCI  acid concentration by mass loss ,and polarization measurements .it was found that (PHTU) is a good inhibitor for the corrosion of low carbon steel in 1,3,and 5N HCI solution ,and its inhibition efficiency (0) increases with its concentration and attains approximately 97% at l g/I .polarization curves indicate that (PHTU) acts as an anodic type inhibitor .the inhibitor was adsorbed on the low carbon steel surface according to the Langmuir adsorption isotherm model. Results show that the rate of corrosion of low carbon steel increased with increasing temperature o

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
Design of six electrode Enzial electrostatic lens low aberrations for electron gun
...Show More Authors

A computerized investigation has been carried out on the design of six electrodes electrostatic lenses used in electron gun application. The Finite-Element Method (FEM) was used in the solution of Laplace equation for determine the axial potential distribution. The electron trajectory under zero magnification condition. The optical properties, spherical and chromatic aberrations, the object and image focal length and object and image position are calculated. A very good futures for the electron gun with these lenses have been computed where are a beam current of 8.7*10-7A can be supplied using cathode tip of radius 10nm.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 24 2026
Journal Name
Journal Of Engineering
Testing and Commissioning of a Low-Speed Wind Tunnel (LSWT) Test Section
...Show More Authors

The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect

... Show More
View Publication
Publication Date
Thu Mar 01 2018
Journal Name
2018 Tenth International Conference On Advanced Computational Intelligence (icaci)
On low-level control strategies of lower extremity exoskeletons with power augmentation
...Show More Authors

View Publication
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Sun Jul 31 2022
Journal Name
Pakistan Journal Of Medical & Health Sciences
Application of program for nurse’s management about care of children treated with Ventricular Peritoneal Shunt
...Show More Authors

Publication Date
Wed Oct 01 2014
Journal Name
2014 44th European Microwave Conference
A low magnetic bias sub-millimetre wave semiconductor junction circulator
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Ieee Access
Low-Distortion MMSE Speech Enhancement Estimator Based on Laplacian Prior
...Show More Authors

View Publication
Scopus (42)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Mixed Linearity Improvement Techniques for Ultra-wideband Low Noise Amplifier
...Show More Authors

<span>We present the linearization of an ultra-wideband low noise amplifier (UWB-LNA) operating from 2GHz to 11GHz through combining two linearization methods. The used linearization techniques are the combination of post-distortion cancellation and derivative-superposition linearization methods. The linearized UWB-LNA shows an improved linearity (IIP3) of +12dBm, a minimum noise figure (NF<sub>min.</sub>) of 3.6dB, input and output insertion losses (S<sub>11</sub> and S<sub>22</sub>)  below -9dB over the entire working bandwidth, midband gain of 6dB at 5.8GHz, and overall circuit power consumption of 24mW supplied from a 1.5V voltage source. Both UWB-LNA and linearized UWB-LNA designs are

... Show More
Scopus (1)
Scopus Crossref