Introduction: Inadequate pain assessment and management is a problem in hospitalized patients that impairs their wellbeing. Intensive care unit nurses’ pain practices are affected by several barriers and enablers. Objectives: The objectives of this study were to determine the level of nurses’ practices and perceived barriers related to pain assessment in critically ill patients. Methodology: A cross-sectional design study was used. Purposive sampling technique was employed, including 100 nurses recruited from 8 intensive care units in Baghdad city, Iraq. The study was conducted from September 1st to October 20th, 2022. The pain assessment and management for critically ill patients survey was used to collect data. Descriptive statistics, Spearman correlation, and chi-square tests were used to analyze the data. Results: The findings of the current study indicate that nearly half (49%) of the respondents were in the age group of 28-37 years old, with a mean age of 33.73 ± 7.045 years. Three-quarters of the respondents were males and the rest were female. The majority (63%) of the respondents held a bachelor’s degree in nursing. More than three-quarters (76%) of the respondents were married. The majority (31%) of the respondents had 6-10 years of service experience in nursing, and most of them had 1-5 years of experience as a nurse in the intensive care unit. Finally, a high percentage of nurses had training courses about pain assessment and management. Conclusions: This study allowed us to recognize the nurse’s practices and the barriers to effective pain assessment and management. The analysis showed that critical care nurses had an acceptable practice level related to pain assessment and management in critically ill patients. Insufficient numbers of nursing staff, workload, and poor communication were identified as common factors that negatively influenced effective pain management.
In this work, spinel ferrites (NiCoFe2O4) were prepared as thin films by dc reactive dual-magnetron co-sputtering technique. Effects of some operation parameters, such as inter-electrode distance, and preparation conditions such as mixing ratio of argon and oxygen in the gas mixture, on the structural and spectroscopic characteristics of the prepared samples were studied. For samples prepared at inter-electrode distance of 5 cm, only one functional group of OH- was observed in the FTIR spectra as all bands belonging to the metal-oxygen vibration were observed. Similarly, the XRD results showed that decreasing the pressure of oxygen in the gas mixture lead to grow more crystal planes in the samples prepare
... Show Moreنحو تعزيز المشاركة السياسية للطالبات الجامعيات الفلسطينيات
In this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
Gas adsorption phenomenon on solid surface has been used as a mean in separation and purification of gas mixture depending on the difference in tendencies of each component in the gas mixture to be adsorbed on the solid surface according to its behaviour. This work concerns to study the possibilities to separate the gas mixture using adsorption-desorption phenomenon on activated carbon. The experimental results exhibit good separation factor at temperature of -40 .
In this research a local adsorbent was prepared from waste tires using two-step pyrolysis method. In the carbonization process, nitrogen gas flow rate was 0.2L/min at carbonization temperature of 500ºC for 1h. The char products were then preceded to the activation process at 850°C under carbon dioxide (CO2) activation flow rate of 0.6L/min for 3h. The activation method produced local adsorbent material with a surface area and total pore volume as high as 118.59m2 /g and 0.1467cm3/g, respectively. The produced . local adsorbent (activated carbon) was used for adsorption of lead from aqueous solution. The continuous fixed bed column experiments were conducted. The adsorption capacity performance of prepared activated carbons in this work
... Show More