Preferred Language
Articles
/
yBY2jooBVTCNdQwC7J4E
Ring Opining polymerization of caprolactone And Antibacterial activity by Mixed Ligand of Metal(II) and (III)
...Show More Authors

Reaction of L1 [((E)-N1-(nitrobenzylidene)benzene-1,2-diamine] and L2( m-aminophenol), and one equivalent of di- or tri-valent metals(Cr(ӀӀӀ), Mn(ӀӀ), Fe(ӀӀӀ), Co(ӀӀ), Ni(ӀӀ), Cu(ӀӀ) and Zn(ӀӀ) afforded the complexes [M(L1)(L2)2]Cl, M=Cr(ӀӀӀ) and Fe(ӀӀӀ) and the complexes [M(L1)(L2)2] M= Mn(ӀӀ), Co(ӀӀ), Ni(ӀӀ), Cu(ӀӀ) and Zn(ӀӀ). The structure of the Schiff base ligand and their complexes are characterized by (C:H:N), FT.IR, UV.Vis, 1HNMR, 13CNMR and mass spectral. The presence of metal in the complexes are characterized by flame atomic absorption. The spectral data of the complexes have revealed the octahedral geometry. The (L1), (L2) and mixed ligand metal complexes were screened for their ability as catalysis for ring opening polymerization and toward antibacterial and antifungal activities on different species of pathogenic bacteria and fungi

View Publication
Publication Date
Tue Oct 20 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Biological Activity of Complexes of Some Amino Acid
...Show More Authors

Biological Activity of Complexes of Some Amino Acid

Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Hard-soft interacation of 2-mercaptobenzonathol with some metal ions
...Show More Authors

Was appointed acid steady disintegration of organic EkandThe results proved that organic Allicand acting and Konnh solid baseBy Tgrav Pearson has possible account Maamat hardness and softness of organic Ekand

View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
Statistical Analysis of Metal Removal during Magnetic Abrasive Finishing Process
...Show More Authors

This work aims to provide a statistical analysis of metal removal during the Magnetic Abrasive Finishing process (MAF) and find out the mathematical model which describes the relationship between the process parameters and metal removal, also estimate the impact of the parameters on metal removal. In this study, the single point incremental forming was used to form the truncated cone made of low carbon steel (1008-AISI) based on the Z-level tool path. Then the finishing was accomplished using a magnetic abrasive process based on the Box-Behnken design of the experiment using Minitab 17 software was used to finish the surface of the formed truncated cone. The influences of different parameters (feed rate, machining step s

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Liquid-Liquid Extraction of Metal Ions Using Aqueous Biphasic Systems
...Show More Authors

An investigation was conducted for the study of extraction of metal ions using aqueous biphasic systems. The extraction of iron, zinc and copper from aqueous sulphate media at different kinds of extractants SCN− , Cl- and I- , different values of pH of the feed solution, phase ratio, concentration of metals, concentration of extractant, concentration of polymer, and concentration of salt was investigated. Atomic absorption spectrophotometer was used to measure the concentration of iron, zinc and copper in the aqueous phase throughout the experiments. The results of the extraction experiments showed the use of SCN− as extractant, pH=2.5, phase ratio=1.5, concentration of metals 1g/l, concentration of extractant 0.06 %, concentration o

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed May 01 2013
Journal Name
Chemical And Process Engineering Research
Synthesis and Characterization of Polycyclicacetal Derived from PEG & Erythro-Ascorbic Acid Derivative and Study Its Effect on the Activity of ACh Enzyme (In Vitro)
...Show More Authors

Polycyclicacetal was prepared from the reaction of PEG with aldehyde derived from Erythro-ascorbic acid (pentulosono-ɣ-lactone-2,3-enedianisoate).All these compounds were characterized by Thin Layer Chromatography (TLC) and FTIR spectra and aldehyde was also characterized by (U.V-Vis), 1HNMR, 13CNMR, and mass spectra.The inhibitory effect of prepared polymer on the activity of human serum AcetylCholinesterase has been studied in vitro. The polymer showed a remarkable activity at low concentration (4.7x10-3 – 4.7x10-8M).

Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Innovation, Creativity And Change
The techno-strategy of the management information system and its role in enhancing risk management in the general directorate of school and sport activity
...Show More Authors

The importance of this research lies in shedding light on the concept of techno-strategy for information management from vital and important topics that showed response for change in all areas of life. As this necessitates the updating and changing of it in order to achieve its strategic goals and enhance its technological advantage. The research problem looked at the role of the information technology system (ITS) in enhancing risk management in general directorates for sports and school activity from the viewpoint of its department heads. The research aimed at the relationship of information techno-strategy in risk management and the ratios of the contribution of information techno-strategy in risk management from the viewpoint of heads o

... Show More
Preview PDF
Scopus (1)
Scopus
Publication Date
Tue Aug 01 2017
Journal Name
International Journal Of Science And Research
Effects of Pregabalin Drug on Level of Reproductive Hormones, Sexual Activity, Number and Weight of Offspring in Female Albino Rats
...Show More Authors

Abstract: This study was aimed to investigate the effect of two doses of pregabalin (PGB) on hormonal level and sexual activity in female albino rats. Ninety female rats with age (9-10 weeks) and weight (200±20 g) were divided into three major groups of thirty rats. First group was considered as control G1, the second G2 and third G3 groups were exposed to PGB into two doses 150, and 300 mg/kg body weight per day respectively. Each major group was divided into three subgroups (subgroup A, B, and C of each has ten rats), the treatments last for one month for subgroup A, two months for subgroup B, and three months for subgroup C. Five rats from each subgroup were placed separately into two breeding cages with two isolated males and wait

... Show More
Preview PDF
Publication Date
Thu Feb 15 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
In Vitro Evaluation of the Activity of Punica granatum L. Aqueous and Methanol Extracts on the Trophozoites of Entamoeba histolytica
...Show More Authors

Background: Entamoeba histolytica is the causative agent of amoebic dysentery and hepatic abscesses. Despite the efficacy of metronidazole in alleviating infectious diseases, the global dissemination of drug-resistant parasites raises the possibility that Punica granatum could serve as an effective natural alternative treatment. Objective: To evaluate the effect of P. granatum methanolic and aqueous extracts of various parts against E. histolytica trophozoites in an in vitro setting. Methods: Various concentrations (0.14, 0.7, 1.4, and 2.8 mg/ml) of P. granatum extracts of the flowers, leafs, peels, and seeds were chosen for this purpose. A culture medium containing 0.05x106/ml E. histolytica trophozoites was treated with different

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jul 01 2018
Journal Name
Journal Of Craniofacial Surgery
Does Mixed Conventional/Piezosurgery Implant Site Preparation Affect Implant Stability?
...Show More Authors

The aim of this study was to compare the effect of conventional implant site preparation technique and a combination of conventional/piezosurgery preparation on implant stability measured at different time intervals, insertion torque, and preparation time. A randomized controlled study was designed, it included 26 patients who received 54 dental implants randomly assigned to 2 groups; in the control group, implants were installed after conventional preparation with drills whereas the study group received implants after mixed conventional/piezosurgery preparation. The outcome variables included: implant stability measured immediately after implant insertion, at 8 weeks and 16 weeks postoperatively, insertion torque and preparation time. All

... Show More
View Publication
Scopus (10)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Mixed Linearity Improvement Techniques for Ultra-wideband Low Noise Amplifier
...Show More Authors

<span>We present the linearization of an ultra-wideband low noise amplifier (UWB-LNA) operating from 2GHz to 11GHz through combining two linearization methods. The used linearization techniques are the combination of post-distortion cancellation and derivative-superposition linearization methods. The linearized UWB-LNA shows an improved linearity (IIP3) of +12dBm, a minimum noise figure (NF<sub>min.</sub>) of 3.6dB, input and output insertion losses (S<sub>11</sub> and S<sub>22</sub>)  below -9dB over the entire working bandwidth, midband gain of 6dB at 5.8GHz, and overall circuit power consumption of 24mW supplied from a 1.5V voltage source. Both UWB-LNA and linearized UWB-LNA designs are

... Show More
Scopus (1)
Scopus Crossref