Preferred Language
Articles
/
xhYDfYgBVTCNdQwCrHd3
Prospective Comparative Study of Fixing Displaced Transverse Patellar Fracture by Tension Band Wiring Versus Cannulated Screws with Wiring
...Show More Authors

BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from April 1, 2019, to October 1, 2020. It included 32 patients with isolated displaced transverse patellar fracture AO type 34-C1. The patients have undergone operative fixation with two different surgical techniques divided randomly by choosing every other patient into two groups. Group A, the fracture was fixed by cannulated screws with wiring and Group B, the fracture was fixed by two K-wires and with tension band technique. Postoperatively, assessment of the knee function by Lysholm score, the visual analog scale for pain intensity, and active flexion range of movement were measured in degree as primary outcomes, while time to union in weeks assessed radiographically as secondary outcomes. RESULTS: The patients’ age was ranging from 26 to 49 years, with males predominant. Low-energy falls occupying a major part of the mechanism of injury in both groups. Lysholm score was significantly increased after 3, 6, and 12 months compared to that after 1 month in both groups with no statistical differences. The mean visual analog score significantly decreased in Group A after 1 month than that in Group B with no significant change in the other follow-up periods. There were no statistically significant differences in both groups regarding the range of knee movement and the radiographic assessment of fracture healing. CONCLUSION: Both techniques are good and effective with taking into consideration that open reduction and cannulated screws fixation with wiring technique is shown to be associated with lower post-operative pain and a lower frequency of complications mainly surgical site infection.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Sumer 3
Treatment of shallow and deep white spot lesions with three different mouthwashes evaluated by laser fluorescence (an in vitro study)
...Show More Authors

This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Study the performance of pentacene based organic field effect transistor by using monolayer, bilayer and trilayer with different gate insulators
...Show More Authors

In this paper, Pentacene based-organic field effect transistors (OFETs) by using different layers (monolayer, bilayer and trilayer) for three different gate insulators (ZrO2, PVA and CYEPL) were studied its current–voltage (I-V) characteristics by using the gradual-channel approximation model. The device exhibits a typical output curve of a field-effect transistor (FET). Source-drain voltage (Vds) was also investigated to study the effects of gate dielectric on electrical performance for OFET. The effect of capacitance semiconductor in performance OFETs was considered. The values of current and transconductance which calculated using MATLAB simulation. It exhibited a value of current increase with increasing source-drain voltage.

Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Biochemical and Histological Study of Aminoacylase-1 Purified from Amniotic Fluid in Rats with Oxidative Stress Induced by Lead Acetate
...Show More Authors

This work involves separating and studying the aminoacylase-1 (ACY1) of amniotic fluid from healthy pregnant, mainly one peak with higher activity has been isolated by DEAE-Cellulose ion exchange from the proteinous supernatant produced by deposition of proteins using ammonium sulfate  (65%) after dialysis. The purification folds reaching to 19 folds also gave one protein peak when injected into the gel filtration column, a high ACY1 purity was obtained, with 38 folds of purification. It was found that the molecular weight of the isolated ACY1 was up to 46698 Dalton when using gel chromatography technique.The effect of ACY1 isolate was studied on rats with oxidative stress caused by lead acetate(LA) at 40 mg / kg body weight and compare

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
The Potential of Recycling Used Engine Oil for Biogas Generation by Co-Digestion with Animals’ Manure: Experimental and Kinetic Study
...Show More Authors

This study investigates the potential of biogas recovery from used engine oil (UEO) by co-digestion with animals’ manure, including cow dung (CD), poultry manure (PM), and cattle manure (CM). The experimental work was carried out in anaerobic biodigesters at mesophilic conditions (37°C). Two groups of biodigesters were prepared. Each group consisted of 4 digesters. UEO was the main component in the first group of biodigesters with and without inoculum, whereby a mix of UEO and petroleum refinery oily sludge (ROS) was the component in the second group of biodigesters. The results revealed that for UEO-based biodigesters, maximum biogas production was 0.98, 1.23, 1.93, and 0 ml/g VS from UEO±CD, UEO±CM, UEO±PM, and U

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 07 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effects of time delay and tension system application after final flask closure on the vertical displacement of acrylic and porcelain teeth in maxillary complete dentures
...Show More Authors

Background: The displacement of artificial teeth during complete denture construction presents major processing errors in the occlusal vertical dimension which were verified at the previous trial denture stage. The aim of this study was to assess the effect of delay in processing after final flask closure and tension application on the vertical acrylic and porcelain teeth displacement of complete dentures constructed from heat cured acrylic and the results were compared with the conventional processing method. Materials and methods: forty samples of identical maxillary complete dentures were constructed from heat polymerized acrylic resin. These samples were subdivided into the following experimental subgroups in which each subgroup contai

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 02 2017
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Umbilical cord drainage versus intraumbilical cord oxytocin injection in management of third stage of labour
...Show More Authors

Background: Postpartum hemorrhage is an important cause of maternal morbidity and mortality. Considerable difference of opinion exist regarding the optimal approach to the management of the 3rd stage of labour, practice varies between countries &between units.Objectives: To evaluate the effectiveness of intra umbilical vein injection of oxytocin and umbilical cord driange in shortening the duration of third stage of labour.Patient and Methods: In this randomized controlled study, 100 women were enrolled in this study they divided into three groups. (Group 1 ,N =30 )received 20 units of oxytocin diluted in 20 ml 0.9% saline solution injected in the umbilical vein after clamping.(Group 2, N = 34) placental cord drainage.(Group 3,

... Show More
Preview PDF
Crossref
Publication Date
Sun Jun 07 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 25 2017
Journal Name
Biomedical And Pharmacology Journal
Comparative Study of the Effect of Incorporating SiO2 Nano-Particles on Properties of Poly methyl Methacrylate Denture Bases
...Show More Authors

View Publication
Crossref (26)
Crossref
Publication Date
Tue Mar 20 2018
Journal Name
Day 2 Wed, March 21, 2018
Numerical Approach for the Prediction of Formation and Hydraulic Fracture Properties Considering Elliptical Flow Regime in Tight Gas Reservoirs
...Show More Authors
Abstract<p>As tight gas reservoirs (TGRs) become more significant to the future of the gas industry, investigation into the best methods for the evaluation of field performance is critical. While hydraulic fractured well in TRGs are proven to be most viable options for economic recovery of gas, the interpretation of pressure transient or well test data from hydraulic fractured well in TGRs for the accurate estimation of important reservoirs and fracture properties (e.g. fracture length, fracture conductivity, skin and reservoir permeability) is rather very complex and difficult because of the existence of multiple flow profiles/regimes. The flow regimes are complex in TGRs due to the large hydraulic fractures n</p> ... Show More
View Publication
Scopus (14)
Crossref (8)
Scopus Crossref
Publication Date
Sun Oct 13 2019
Journal Name
Spe Kuwait Oil & Gas Show And Conference
Optimization of Fracture Parameters for Hydraulic Fractured Horizontal Well in a Heterogeneous Tight Reservoir: An Equivalent Homogeneous Modelling Approach
...Show More Authors
Abstract<p>Building numerical reservoir simulation model with a view to model actual case requires enormous amount of data and information. Such modeling and simulation processes normally require lengthy time and different sets of field data and experimental tests that are usually very expensive. In addition, the availability, quality and accessibility of all necessary data are very limited, especially for the green field. The degree of complexities of such modelling increases significantly especially in the case of heterogeneous nature typically inherited in unconventional reservoirs. In this perspective, this study focuses on exploring the possibility of simplifying the numerical simulation pr</p> ... Show More
View Publication
Scopus (25)
Crossref (17)
Scopus Crossref