BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from April 1, 2019, to October 1, 2020. It included 32 patients with isolated displaced transverse patellar fracture AO type 34-C1. The patients have undergone operative fixation with two different surgical techniques divided randomly by choosing every other patient into two groups. Group A, the fracture was fixed by cannulated screws with wiring and Group B, the fracture was fixed by two K-wires and with tension band technique. Postoperatively, assessment of the knee function by Lysholm score, the visual analog scale for pain intensity, and active flexion range of movement were measured in degree as primary outcomes, while time to union in weeks assessed radiographically as secondary outcomes. RESULTS: The patients’ age was ranging from 26 to 49 years, with males predominant. Low-energy falls occupying a major part of the mechanism of injury in both groups. Lysholm score was significantly increased after 3, 6, and 12 months compared to that after 1 month in both groups with no statistical differences. The mean visual analog score significantly decreased in Group A after 1 month than that in Group B with no significant change in the other follow-up periods. There were no statistically significant differences in both groups regarding the range of knee movement and the radiographic assessment of fracture healing. CONCLUSION: Both techniques are good and effective with taking into consideration that open reduction and cannulated screws fixation with wiring technique is shown to be associated with lower post-operative pain and a lower frequency of complications mainly surgical site infection.
Many complexes of 3,5-dimethyl-1H-pyrazol-1-yl phenyl methanone with Cr(III), Co(II), Ni(II), Cu(II) and Cd(II) were synthesized and characterized by FT-IR, UV/visible spectra, elemental analysis, room temperature magnetic susceptibility and molar conductivity. Cd(II) complex was expected to have tetrahedral structure while all the other complexes were expected to have an octahedral structure.
mixtures of cyclohexane + n-decane and cyclohexane + 1-pentanol have been measured at 298.15, 308.15, 318.15, and 328.15 K over the whole mole fraction range. From these results, excess molar volumes, VE , have been calculated and fitted to the Flory equations. The VE values are negative and positive over the whole mole fraction range and at all temperatures. The excess refractive indices nE and excess viscosities ?E have been calculated from experimental refractive indices and viscosity measurements at different temperature and fitted to the mixing rules equations and Heric – Coursey equation respectively to predict theoretical refractive indices, we found good agreement between them for binary mixtures in this study. The variation of th
... Show MoreAbstract
Objectives: The present study designed to explore the genotoxicity through measurement of Mitotic index in bone marrow and the spleen cells, as possible mechanism of bone marrow and spleen toxicity that induced by irinotecan; and to describe the protective actions of omega 3 against irinotecan induced genotoxicity in bone marrow and the spleen of rats.
Methods: Twenty four (24) rats (Sprague-Dawley) were randomly divided into four groups: Group Ӏ, rats received single oral daily dose of distilled water (2 ml/kg) for 25 days (negative control group); Group ӀӀ (irinotecan-treated), receiv
... Show MoreThe wave functions of converted harmonic-oscillator in local scaling transformations are employed to evaluate charge distributions and elastic charge electron scattering form structures for 6,7Li, 9Be, 14,15N and 16O nuclei. The nuclear shell-model was fulfilled using Warburton-Brown psd-shell (WBP) interaction with truncation in model space. Very good agreements with the experimental data were obtained for the aforementioned quantities.
The Boltzmann transport equation is solved by using two- terms approximation for pure gases . This method of solution is used to calculate the electron energy distribution function and electric transport parameters were evaluated in the range of E/N varying from . 172152110./510.VcmENVcm
From the results we can conclude that the electron energy distribution function of CF4 gas is nearly Maxwellian at (1,2)Td, and when E/N increase the distribution function is non Maxwellian. Behavior of electrons transport parameters is nearly from the experimental results in references. The drift velocity of electron in carbon tetraflouride is large compared with other gases
The Boltzmann transport equation is solved by using two- terms approximation for pure gases and mixtures. This method of solution is used to calculate the electron energy distribution function and electric transport parameters were evaluated in the range of E/N varying from . 172152110./510.VcmENVcm
The electron energy distribution function of CF4 gas is nearly Maxwellian at (1,2)Td, and when E/N increase the distribution function is non Maxwellian. Also, the mixtures are have different energy values depending on transport energy between electron and molecule through the collisions. Behavior of electrons transport parameters is nearly from the experimental results in references. The drift velocity of electron in carbon tetraflouride i
Background: Decalcification of surface enamel adjacent to fixed orthodontic appliances, in the form of white spot lesions, is a wide spread and familiar well-known side effect of orthodontic treatment. The present study was carried out to evaluate the effect of enamel protective agent (Clinpro white varnish) on shear and tensile bond strength of Dentaurum orthodontic stainless steel brackets by using 3M Unitek and Ormco as orthodontic adhesive agents. Materials and methods: Sixty-four extracted human upper first premolar teeth were selected and randomly divided into two groups with 32 teeth each, representing the shear and tensile bond strength testing groups. Then according to the type of bonding adhesive and the addition of Clinpro before
... Show MorePractical application is an effective tool for preparing qualified scientific and technical cadres if applied correctly and efficiently. In addition to being the complementary part of everything that has been studied in the years of study, it is a scientific linking tool between theory and application. Here lies the importance of this research in clarifying the central and important role that practical application plays in general in raising the scientific level of the student, and the extent of the suitability of the curriculum and means of practical application and the extent and needs of the students applying at the Institute of Administration - Rusafa - Department of Information Technology and Libraries. This research attempted to answe
... Show MoreBackground: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i
... Show More