Preferred Language
Articles
/
xUI4eZoBMeyNPGM31sys
Determination of Cobalt(II) Ion in Various Selected Alloys via Utilizing Continous Flow Injection Analysis ((CFIA) (Nagham-Four Sources of White  Snow LED Arranged in Three Rows Corresponding to Three Detectors Analyzer) (NAG-4SX3-3D)) Analyzer at 0-180o Angle
...Show More Authors

The research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5 and 10 mM, the relative standard deviation (RSD) for eight repeated intraday measurements is less than 0.36%. The calibration graph gradually dilutes the lowest concentration to determine the limit of detection (LOD) of 349.236 ng per analyte sample. The correlation coefficient (r) for the linear dynamic range is 0.9893, and the linearity is 97.80% (R2 %).  The results of the proposed method were compared to the already-available UV-spectrophotometric technique at a wavelength of 510 nm and found to be comparable..  

Scopus Crossref
View Publication
Publication Date
Thu Jun 15 2023
Journal Name
Journal Of Craniofacial Surgery
Evaluation of the Lingual Splitting Patterns and the Lateral Bone Cut Ends Following Mandibular Bilateral Sagittal Split Osteotomy Using Cone Beam Computed Tomography (CBCT)
...Show More Authors

The bilateral sagittal split osteotomy (BSSO) is the most popular orthognathic procedure performed by maxillofacial surgeons to treat skeletal class II and class III and to correct mandibular asymmetries. The study aimed to evaluate the lingual splitting patterns and lateral bone cut end (LBCE) in bilateral sagittal split osteotomy (BSSO) and their relation with the ramal thickness and the presence of impacted third molars using cone beam computed tomography (CBCT). This prospective observational study included patients with mandibular prognathism who were treated with BSSO with or without Le Fort I osteotomy. Cone beam computed tomography was used to measure the ramal thickness preoperatively and to evaluate the LBCE, and the lingu

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Sep 30 2025
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Improving the elimination of methyl orange dye by combining electrocoagulation system with the adsorption process by oven-dried alum sludge: adopting different combined systems
...Show More Authors

   Due to their recalcitrant characteristics, Azo dyes such as methyl orange (MO) are extremely poisonous substances, making their removal from textile industry wastewater a major problem. By employing various EC-Adsorption combined system configurations and reusing alum sludge as an adsorbent, the current study seeks to investigate the efficiency of these various systems in removing MO dye. To estimate their benefits and limitations, experiments were carried out utilizing nickel foam (NiF) and aluminum plate (Al plate) as anodes, and stainless-steel mesh (SS mesh) as cathode in the presence of alum sludge as an adsorbent in all systems. The EC-Adsorption combined system with NiF as anode and two SS meshes as cathodes with 10 g/L

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Mar 08 2020
Journal Name
Biochem. Cell. Arch
SYNTHESIS AND SPECTROSCOPIC CHARACTERIZATION OF NEW HETEROCYCLIC COMPOUNDS DERIVATIED FROM 1-(4-AMINOPHENYL) ETHAN-1-ONEOXIME AS A STARTING MATERIAL WITH EVALUATE THEIR BIOLOGICAL ACTIVITY
...Show More Authors

ABSTRACT : This research involves the synthesis of five to seven heterocyclic compounds starting with Schiff’s bases which derived from oxime as a starting material. 1.3-oxazepine derivatives were prepared from adding different anhydrides to the Schiff bases, tetrazole and thiazolidinone derivatives synthesized from add sodium azide and thioglycolic acid to the same Schiff’s bases as a five members ring. Pyrimidine derivatives were prepared after the reaction of the azomethine group with acetyl chloride and then urea and thiourea to synthesis on derivatives contain the six members ring. Another step included identified and confirmed these compounds by FT- IR, 1HNMR, TLC and 13CNMR finally, step included the assay of biological activity

... Show More
Publication Date
Wed Dec 01 2021
Journal Name
International Medical Journal
Effect of Accelerated Canine Retraction by Vitamin D3 Local Administration on Apical Root Resorption, Alveolar Bone Integrity, and Chair-side Time: A Prospective Clinical Study.
...Show More Authors

Objectives: To evaluate the effect of vitamin D3 local injections on apical root resorption, alveolar bone integrity, and chair-side time following three and six months of canine retraction. Subjects and Methods: Seventeen adult patients (18-35 years old) of class I and II malocclusions were recruited, who required bilateral maxillary 1st premolars extraction before starting maxillary canines retraction. The experimental side received 25 pg dose of vitamin D3 injected locally into the distal periodontal sulcus of the canine (before force application) every three weeks, while the control side received retraction force only. Periapical radiographic evaluation was conducted after 3 and 6 months of the start of canines' retraction. Results: At

... Show More
Preview PDF
Publication Date
Sun Feb 28 2021
Journal Name
Journal Of Electrochemical Science And Technology
Simultaneous Removal of Cadmium and Copper from a Binary Solution by Cathodic Deposition Using a Spiral-Wound Woven Wire Meshes Packed Bed Rotating Cylinder Electrode
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Samarra Journal Of Pure And Applied Science
Synthesis, Spectral Characterization and Biological Activity of Schiff Base ligand Derived from 5-amino-2-phenyl-2,4-dihydro3H-Pyrazol-3-one and its Metal Complexes
...Show More Authors

Eight new complexes with the general formula [M(L)2(H2O)2] were prepared resulting from the reaction of the new Schiff base ligand [(E)-5- ((2-hydroxybenzylidene)amino)-2-phenyl-2,4-dihydro-3H-pyrazol-3- one(L)] with metal ions [manganese, cadmium, zinc, copper, nickel, cobalt, Mercury Bivalent and tetravalent platinum. This ligand was derived from the reaction of the amine (5-amino-2-phenyl-2,4-dihydro3H-pyrazol-3-one) with Salicylaldehyde, which is linked to the metal ions via two atoms. The nitrogen is the isomethene group, and the oxygen is the hydroxide group of the pyrazoline ring. The prepared compounds were characterized using infrared spectroscopy, nuclear magnetic resonance spectroscopy, and ultraviolet spectroscopy, and from the

... Show More
Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
THE EFFECT OF EXERCISES USING A MINI SQUASH COURT ON IMPROVING SOME MOTOR ABILITIES AND LEARNING SOME BASIC SKILLS FOR PLAYERS AGED 10-12 YEARS
...Show More Authors

Publication Date
Sun Dec 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal Of Dissolved Cadmium Ions from Contaminated Wastewater using Raw Scrap Zero-Valent Iron And Zero Valent Aluminum as Locally Available and Inexpensive Sorbent Wastes
...Show More Authors

The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed wer

... Show More
View Publication Preview PDF
Crossref (12)
Crossref