Background: Common and persistent isolate ina the teeth following failed therapy of the root canal is the gram-positive facultative bacterium Enterococcus faecalis and Escherichia coli, which develop biofilm through a complicated process that results in the formation of a biofilm. Enterococcus faecalis and Escherichia coli are significant factors that cause chronic periradicular lesions after root canal therapy. Aim: This study aimed to treat the root canal tooth infected with Escherichia coli and Enterococcus faecalis Methods: In this study biofilm formation was done for Escherichia coli in growth phase cultured in a brain heart broth Enterococcus faecalis and Escherichia coli cultured in Luria-Bertani (LB) infusion medium for 18 hrs. Then we studied the effect of plasma jet that works with argon gas, and it is generated by a power supply that operates at alternating high voltages in the form of a sinusoidal wave with peak-to-peak value of about 12 kV at a frequency of 30 KHz and its power is about 200 watts. Results: Enterococcus faecalis biofilms were treated for 0.5, 1, 1.5, 2, 2.5 minute with a constant gas flow rate 2.5 . The killing rate decreased from (0.979 to 0.361). In the Enterococcus faecalis biofilms was treated for a longer period of time (5, 10, 15, 20, 25, 30) min, as the killing rates decreased from (0.739 to 0.179). Conclusions: The result of this study indicates that plasma jet is useful in disinfecting root canal tooth and reducing the formation of biofilm.
The research aims to study the reliability of government institutions, including the audit directors, which are one of the most important oversight formations in the Ministry of Construction, Housing and Public Municipalities, on which the responsibility for comprehensive auditing of all the Ministry's (municipalities) formations falls on the Managing the Audit Program according to the specification (ISO 19011: 2018) to improve the audit performance which requires compliance with the application of the audit management system in accordance with the standard Specification (ISO 19011: 2018), depending on the methodology of the case study, and using of checklists, which were chosen ac
... Show MoreAn accurate assessment of the pipes’ conditions is required for effective management of the trunk sewers. In this paper the semi-Markov model was developed and tested using the sewer dataset from the Zublin trunk sewer in Baghdad, Iraq, in order to evaluate the future performance of the sewer. For the development of this model the cumulative waiting time distribution of sewers was used in each condition that was derived directly from the sewer condition class and age data. Results showed that the semi-Markov model was inconsistent with the data by adopting ( 2 test) and also, showed that the error in prediction is due to lack of data on the sewer waiting times at each condition state which can be solved by using successive conditi
... Show MoreObjectives: The study aims to assess the nurses knowledge toward prevention of complications related to valvular replacement surgery and to find out the relationship between nurses knowledge and their demographic and occupational characteristic's Which as (Age, gender, level of education ,years of experience in Surgical Department , and training sessions)
Methodology: A descriptive design (a cross-sectional study ) was carried out from December 2017 to May 2018 in order to assess nurses' knowledge of preventing complications Valvular Replacement Surgery at Surgical Department in Nasiriyah Heart Center on a purposive (non-probability) sample
... Show MoreObjective: To assess the major anti-tuberculosis drugs available to patients at primary health care centers in Baghdad city. Methodology: A descriptive cross-sectional study design is carried out in order to achieve the objectives of the study by using the assessment technique in primary health care centers from December 29th, 2014 to July 10 th, 2015. probability sampling is select based on the study design. Eighteen primary health care centers are select according to criteria of sample to the study and for the purpose of the study, is select (6) sectors and (11) Primary Health Care Centers (PHCC) from Bagh
Stick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.
Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.
Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance
... Show MoreBackground: The study aim was to evaluate thermocycling effect on microleakage of occlusal and cervical margins of MOD cavity filled with bulk filled composites in comparison to incrementally placed nanohybrid composite and to evaluate the difference in microleakage between enamel and dentin margins for the three materials groups. Materials and method: Forty eight maxillary first premolars were prepared with MOD cavities. Samples were divided into three groups of sixteen teeth according to material used: Grandio: Grandio. SDR: SDR +Grandio. X-tra: X-tra base + Grandio. Each group was subdivided into two according to be thermocycled or not. After 24 hrs immersion in 2% methylene blue, samples weresectioned and microleakage was estimated. Res
... Show MoreAtenolol was used with ammonium molybdate to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and ammonium molybdate in an aqueous medium to obtain a dark brown precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.1-3.5 mmol/L for cell A and 0.3-3.5 mmol/L for cell B, and LOD 133.1680 ng/100 µL and 532.6720 ng/100 µL for cell A and cell B respectively with correlation coefficient (r) 0.9910 for cell A and 0.9901 for cell B, RSD% was lower than 1%, (n=8) for the determination of ate
... Show MoreENGLISH