Abstract. This work presents a detailed design of a three-jointed tendon-driven robot finger with a cam/pulleys transmission and joint Variable Stiffness Actuator (VSA). The finger motion configuration is obtained by deriving the cam/pulleys transmission profile as a mathematical solution that is then implemented to achieve contact force isotropy on the phalanges. A VSA is proposed, in which three VSAs are designed to act as a muscle in joint space to provide firm grasping. As a mechatronic approach, a suitable type and number of force sensors and actuators are designed to sense the touch, actuate the finger, and tune the VSAs. The torque of the VSAs is controlled utilizing a designed Multi Input Multi Output (MIMO) fuzzy controller. The fuzzy controller input is the force sensors' signals that are used to set the appropriate VSA torque. The fuzzy controller parameters are then tuned using a genetic algorithm as an optimization technique. The objective function of the genetic algorithm is to avoid unbalance torque in the individual joints and to reduce the difference between the values of the supplied VSAs torques. Finally, the operation of the aforementioned finger system is organized through a simple control algorithm. The function of this algorithm is to enable the detection of the unknown object and simultaneously automatically activate the optimized fuzzy controller thus eliminating the necessity of any external control unit.
This paper deals with modelling and control of Euler-Bernoulli smart beam interacting with a fluid medium. Several distributed piezo-patches (actuators and/or sensors) are bonded on the surface of the target beam. To model the vibrating beam properly, the effect of the piezo-patches and the hydrodynamic loads should be taken into account carefully. The partial differential equation PDE for the target oscillating beam is derived considering the piezo-actuators as input controls. Fluid forces are decomposed into two components: 1) hydrodynamic forces due to the beam oscillations, and 2) external (disturbance) hydrodynamic loads independent of beam motion. Then the PDE is discretized usi
Bipedal robots, designed to replicate human locomotion, face significant balance challenges due to instability and high degrees of freedom. This study examines dynamical models, balance control strategies, and locomotion methodologies. Dynamical models are categorized into simplified, centroidal dynamics, and whole-body dynamics models. Simplified models, such as the Linear Inverted Pendulum Model (LIPM), approximate the robot as a point mass at the Center of Mass (CoM) but neglect upper-body dynamics and complex terrain interactions. Centroidal dynamics models incorporate CoM motion, contact forces, and angular momentum for improved disturbance rejection but require extensive computational resources. Whole-body models achieve high
... Show MoreCurrently, there is an intensive development of bipedal walking robots. The most known solutions are based on the use of the principles of human gait created in nature during evolution. Modernbipedal robots are also based on the locomotion manners of birds. This review presents the current state of the art of bipedal walking robots based on natural bipedal movements (human and bird) as well as on innovative synthetic solutions. Firstly, an overview of the scientific analysis of human gait is provided as a basis for the design of bipedal robots. The full human gait cycle that consists of two main phases is analysed and the attention is paid to the problem of balance and stability, especially in the single support phase when the biped
... Show MoreBACKGROUND: Genetic skeletal abnormalities are a heterogeneous group of genetic disorders frequently presenting with disproportionate short stature. AIM OF THE STUDY: To give an idea about the frequency of genetic skeletal abnormalities, and to find out whether these disorders are really increasing in the last 16 years or not. METHODS: During the period extending from (Jan, 1st 2003-April, 1st 2007), all cases of genetic skeletal disorders referred to the Genetic Counseling Clinic, Medical City – Baghdad who were born after 1991 were included in this study as the post-war group; the pre-war group, included all cases of skeletal disorders referred prior to 1991 (Jan., 1st 1987-Jan., 1st 1990). The demographic parameters, family history of
... Show MoreTraditional healthcare for chronic wounds and Cold Atmospheric Plasma (CAP) treatments relies on passive dressings and large-volume stationary equipment operating with open-loop systems, which severely limits their use and confines it to specialized clinical environments. To address the lack of active thermal safety mechanisms in mobile devices, this research proposes a wearable smart plasma patch equipped with a closed-loop adaptive electronic control system to ensure safe patient care and treatment at home. The smart patch integrates real-time analog biosensors to continuously monitor skin temperature and relative humidity. An algorithm running on a microcontroller dynamically adjusts the high-voltage plasma parameters using Pulse
... Show MorePurpose: The research aims to study the measurement of the performance of accounting units level of the research sample by using the Federal quality Model European (EFQM) Design/methodology/approach: the (EFQM) which included seven dimensions "Leadership, Strategic Planning, External Focus, Information and Analysis, Faculty / Staff and Workplace Focus, Process Effectiveness & Outcomes and Achievements" And its effect on the Control Environment, which includes three dimensions: "Integrity, management philosophy and commitment to powers" . the sample is supervisory units of colleges affiliated with the University of Baghdad in Iraq, and a sample was chosen that included fifty-one individuals in the accounting departments.
... Show MoreThis study identified intellectual and applied research in key variables (Strategic Control and Strategic Pitfalls) through internal dimensions then founded the (Federal Board of Supreme Audit) is the good area for analyzing the relationship and effect between variables by (125) questionnaire selected from (148) was distributed to the top and middle management as a seniors in controlling action. Appropriate methods, statistical tools, and programs were used to enhance the basic outputs, represented as a set of Conclusions and recommendations from the real control work with a specificity of potential Pitfalls in the effectiveness impact by Strategic Control in other dimensions which Studied.
There are many configurations of directional control valve. Directional control valve has complex construction, such as moving spool to control the direction of actuator and desired speed. Magneto-rheological (MR) fluid is one of controllable fluids. Utilizing the MR fluid properties, direct interface can be realized between magnetic field and fluid power without the need for moving parts like spool in directional control valves. This paper presents the design of multi configuration MR directional control valve. The construction and the principle of work of the valve are presented. The experiment was conducted to show the working principle of the valve functionally. The valve worked proportionally to control the direction and speed of hydra
... Show More
