Ion Pair-dispersive Liquid–Liquid Microextraction Combined with Spectrophotometry for Carbamazepine Determination in Pharmaceutical Formulations and Biological Samples
...Show More Authors

A simple, economical and selective method employing ion pair dispersive liquid−liquid microextraction (DLLME) coupled with spectrophotometric determination of carbamazepine (CBZ) in pharmaceutical preparations and biological samples was developed. The method is based on reduction of Mo(VI) to Mo(V) using a combination of ammonium thiocyanate and ascorbic acid in acidic medium to form a red binary Mo(V) thiocyanate complex. After addition of CBZ to the complex, extraction of the formed CBZ−Mo(V)−(SCN)6 was performed using a mixture of methylene chloride and methanol. Then, the measurement of target complex was performed at the wavelength of 470 nm. The important extraction parameters affecting the efficiency of DLLME were studied and optimized in detail. At the optimum conditions, the linear range was 0.02–0.2 µg/mL. Moreover, the limits of detection and quantification were 0.01 and 0.04 µg/mL, respectively. High enrichment factor was obtained (118). Good recoveries at 0.06, 0.15 and 0.2 µg/mL ranging from 93 to 102% were achieved. The proposed method was successfully applied to the determination of CBZ in pharmaceutical formulations and biological samples.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Oct 06 2023
Journal Name
Journal Of Electrochemical Science And Engineering
Zinc (II) removal from simulated wastewater by electro-membrane extraction approach: Adopting an electrolysis cell with a flat sheet supported liquid membrane
...Show More Authors

The aim of this study is to utilize the electromembrane extraction (EME) system as a manner for effective removal of zinc from aqueous solutions. A novel and distinctive electrochemical cell design was adopted consisting of two glass chambers, a supported liquid membrane (SLM) housing a polypropylene flat membrane infused with 1-octanol and a carrier. Two electrodes were used, a graphite as anode and a stainless steel as cathode. A comprehensive examination of several influential factors including the choice of carrier, the applied voltage magnitude, the initial pH of the donor solution, and the initial concentration of zinc was performed, all in a concerted effort to ascertain their respective impacts on the efficiency of zinc elim

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Nov 13 2019
Journal Name
Al-kindy College Medical Journal
Disturbances of Amino Acid Metabolism in Neurologic Disorders detected by fluorescent high performance liquid chromotograghy (HPLC) in Baghdad - IRAQ
...Show More Authors

Background:Amino acid disorders are a major group of inborn error metabolism (IEM) with variable clinical presentation; its diagnosis constitutes a real challenge in a community with high consanguinity rate and no systematic newborn screening.

Objectives: to provide data about amino acid disorders detected in high-risk Iraqi children by using quantitative amino acid fluorescent high performance liquid chromatography (HPLC) analysis.

Type of the study: Cross-sectional study.

Methods: a descriptive cross sectional study from 1st February to 1st December 2014, at Neurological ward and clinic of the Children Welfare teaching Hospital, in Baghdad - Ira

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Computers & Mathematics With Applications
Boundary element formulations for the numerical solution of two-dimensional diffusion problems with variable coefficients
...Show More Authors

View Publication
Crossref (25)
Crossref
Publication Date
Sat Nov 15 2025
Journal Name
Baghdad Science Journal
Synthesis, Characterization and Biological Activity Studies of New Metal Ion Complexes With Schiff Base Derived from (Z)-3-Hydrazineylidene-1-Phenylpyrazolidine and Evaluating Them as Antioxidants
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Jul 24 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Impact of Exposure Period to Liquid Nitrogen Vapor on Criteria of Human Spermatozoa Cryopreserved in New Cryopreservation Technique
...Show More Authors

Abstract Background: The emptied sheep’s ovarian follicles recently used as a container for spermatozoa during cryopreservation, it was found a proper carrier to cryopreserving spermatozoa in vapor-dependent cryopreservation. The aim of this study was to evaluate the effect of two periods of exposure to liquid nitrogen (LN2)vapor on the parameter of spermatozoa during cryopreservation in this technique. Method: The study was conducted on 30 semen samples from patients with oligozoospermia diagnosed by semen analysis according to the standard criteria of World Health Orgnization (WHO) 2010. Sheep’s ovarian follicles obtained from local slaughterhouse and prepared by slicing the ovaries and evacuating the follicular fluid and oocyt

... Show More
View Publication
Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
CALCULATION OF EXCESS MOLAR VOL-UMES OF SOME TERNARY LIQUID MIX-TURES AT 303.15 K
...Show More Authors

Excess molar volumes of five ternary mixtures of 2- methoxy ethanol(1) +butyl acetate(2)+benzene(3), +toluene(3), +chlorobenzene(3), +bromobenzene(3), and +nitrobenzene(3) have been measured at 303.15K. The excess molar volume exhibited positive deviation over the entire range of composition in the systems 2-methoxy ethanol(1)+ butyl acetate(2)+ benzene(3),+toluene(3) and sigmoid behavior in the case of the remaining systems. Flory's statistical theory have been extended to predict the excess molar volumes of the five ternary mixtures at 303.15 k over a wide range of composition . An excellent agreement has been found between the experimental and theoretical excess molar volumes , both in magnitude and sign .

View Publication Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Physics: Conference Series
Synthesis of Ag/Au (core/shell) nanoparticles by laser ablation in liquid and study of their toxicity on blood human components
...Show More Authors
Abstract<p>Q-switch Nd: YAG laser of wavelengths 235nm and 1,460nm with energy in the range 0.2 J to 1J and 1Hz repetition rate was employed to synthesis Ag/Au (core/shell) nanoparticles (NPs) using pulse laser ablation in water. In this synthesis, initially the silver nano-colloid prepared via ablation target, this ablation related to Au target at various energies to creat Ag/Au NPs. Surface Plasmon Resonance (SPR), surface morphology and average particle size identified employing: UV-visible spectrophotometer, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The absorbance spectra of Ag NPs and Ag/Au NPs showed sharp and single peaks around 400nm and 410nm, respec</p> ... Show More
View Publication
Scopus (67)
Crossref (45)
Scopus Crossref
Publication Date
Thu Jan 01 2026
Journal Name
Rsc Advances
A dual-angle optoelectronic flow injection platform for ferrous ion (Fe <sup>2+</sup> ) determination using blue LED excitation and solar cell detection
...Show More Authors

A new optoelectronic flow injection method is proposed for the determination of ferrous ions (Fe 2+ ) based on thiocyanate complexation to form a deep-red FeSCN 2+ complex.

View Publication Preview PDF
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
A Study on the Stability of Different Frusemide Liquid Dosage Formulas: Oral Solution, Syrup, Elixir, Suspension and Emulsion
...Show More Authors

The present study aim at preparing frusemide in liquid form suitable for oral use. This is achieved through preparing different liquid forms of frusemide. The frusemide liquid is prepared in the following forms: oral solution, syrup and elixir with intensity of 1, 0.4 and 0.8% weight /volume respectively and in combination with potassium carbonate, polysorbate 80, alcohol and phosphate buffer solution of pH8 to dissolve the frusemide in the above mentioned forms. The different forms of the prepared medicine have been stored in glass bottles that can provide protection against light and at 40, 50, 600C for four months. Besides the pH has been checked to decide the period of validity. The results show that the expiration date of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 05 2023
Journal Name
Engineering, Technology & Applied Science Research
Performance Evaluation of Emulsion Liquid Membrane on Chlorpyrifos Pesticide Removal: Stability, Mass Transfer Coefficient, and Extraction Efficiency Studies
...Show More Authors

Emulsion Liquid Membrane (ELM) is an emerging technology that removes contaminants from water and industrial wastewater. This study investigated the stability and extraction efficiency of ELM for the removal of Chlorpyrifos Pesticide (CP) from wastewater. The stability was studied in terms of emulsion breakage. The proposed ELM included n-hexane as a diluent, span-80 as a surfactant, and hydrochloric acid (HCl) as a stripping agent. Parameters such as mixing speed, aqueous feed solution pH, internal-to-organic membrane volume ratio, and external-to-emulsion volume ratio were investigated. A minimum emulsion breakage of 0.66% coupled with a maximum chlorpyrifos extraction and stripping efficiency were achieved at 96.1% and 95.7% at b