Preferred Language
Articles
/
whY5LIcBVTCNdQwCWzuh
Optimum Separation Pressure for Heavy Oils Sequential Separation
...Show More Authors
Abstract<p>The estimation of quantity of liquid that is collected from gas/oil separation system is a very complex task because it requires the application of the flash calculations which needs to solve the cubic equation of state and to use some numerical techniques. These difficulties can be overcome by a computer model which requires a lot of experimental data, long time, and experience.</p><p>This paper adopts a new technique to simplify this problem. It suggests new correlations for optimum separator pressure for separation station of heavy oils. The correlations have been achieved for two- and three- stage separation systems.</p><p>The correlations have been created depending on many Iraqi oil samples. The optimum separator pressure of each individual separator was found at the maximum amount of liquid recovered with the minimum oil formation volume factor.</p><p>The Optimum Separator Soave – Redlich – Kwong model (OSSRK) has been adopted to estimate the optimum separator pressure, while the objective functions, like oil formation volume factor, are predicted by Separator Flash Soave – Redlich – Kwong model (SFSRK) (Hassan 2004).</p><p>The optimum separator pressures have been correlated with mole percent of hexane plus in the well stream fluid, mole percent of methane in the well stream fluid, temperature of the separator and the optimum pressure of the previous separator. Nonlinear multiple regression analysis has been applied to get the best correlation for each system.</p><p>Many statistical tests are used to check the validity of the proposed correlations.</p><p>The error percents of API, GOR, Bo between the optimal cases for each model and the relevant correlations show a maximum of 0.047%, 0.3% and 0.15% for two – stage systems, and 0.2%, 0.6% and 0.22% for three – stage systems. Also the cross plot method is applied to test the correlation validity. These checks are good indication to use these correlations with high degree of confidence.</p>
Scopus Crossref
View Publication
Publication Date
Thu Apr 25 2019
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SEPARATION OF PROTEIN AND LACTOSE FROM WHEY DISPOSED FROM ABO-GHRAAB DAIRY FACTORY BY USING MEMBRANE TECHNOLOGY: SEPARATION OF PROTEIN AND LACTOSE FROM WHEY DISPOSED FROM ABO-GHRAAB DAIRY FACTORY BY USING MEMBRANE TECHNOLOGY
...Show More Authors

In this research, the performance of a two kind of membrane was examined to recovering the nutrients (protein and lactose) from the whey produced by the soft cheese industry in the General Company for Food Products inAbo-ghraab.Wheyare treated in two stages, the first including press whey into micron filter made of poly vinylidene difluoride (PVDF) standard plate type 800 kilo dalton, The membrane separates the whey to permeate which represent is the main nutrients and to remove the fat and microorganisms.The second stage is to isolate the protein by using ultra filter made of polyethylsulphone(PES)type plate with a measurement of 10,60 kilo dalton and the recovery of lactose in the form of permeate.
The results showed that the percen

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Separation and Determination of Some Organic Acids in Dry Calyces of Iraqi Hibiscus Sabdariffa Linn
...Show More Authors

A new reversed phase- high performance liquid chromatographic (RP-HPLC) method with Ultraviolet-Visible spectrophotometry has been optimized and validated for the simultaneous extraction and determination of organic acids present in Iraqi calyces of Hibiscus Sabdraffia Linn. The method is based on using ultrasonic bath for extracting organic acids. Limit of detection in µg/ml of Formic acid, Acetic acid, Oxalic acid, Citric acid, Succinic acid, Tartaric acid, and Malic acid 126.8498×10-6, 113.6005×10-6, 97.0513×10-6, 49.7925×10-6, 84.0753×10-6, 92.6551×10-6, and 106.1633×10-6 ,respectively. The concentration of organic acids found in dry spacemen of calyces of Iraqi Hibiscus Sabdraffia Linn. under study: Formic acid, Acetic acid,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jul 17 2018
Journal Name
International Journal Of Adaptive Control And Signal Processing
Single channel informed signal separation using artificial-stereophonic mixtures and exemplar-guided matrix factor deconvolution
...Show More Authors

View Publication
Scopus (11)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Political Sciences Journal
Electoral appeals and the separation of organic health In the Constitution of the Republic of Iraq for the year (2005)
...Show More Authors

الخلاصة

تعد الانتخابات بمثابة الطريق المؤدي إلى الديمقراطية كونها النمط الأكثر شيوعاً لمشاركة المواطنين في الحياة السياسية للبلدان واختيار ممثليهم في المجالس التشريعية، حيث أن مطلب إجراء انتخابات حرة ونزيهة لم يعد مطلباً داخلياً فحسب بل مطلباً دولياً يصرّ المجتمع الدولي على الوفاء به وهذا يلقي على عاتق كل دولة أن تضع من الضمانات ما يكفل ممارسة هذه الانتخابات ب

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 27 2022
Journal Name
Chemical Papers
Synthesis, characterization, and application of external gelation of sodium alginate nanoparticles in molecular imprinting for separation and drug delivery of tenoxicam
...Show More Authors

View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Effect of electrode separation in magnetron DC plasma sputtering on grain size of gold coated samples
...Show More Authors

In this work, an experimental research on a low voltage DC magnetron plasma sputtering (0-650) volt is used for coating gold on a glass substrate at a constant pressure of argon gas 0.2 mbar and deposition time of 30 seconds. We focused on the effects of operating conditions for the system such as, electrode separation and sputtering current on coated samples under the influence of magnetic flux. Electron temperature and electrons and ions densities are determined by a cylindrical single Langmuir probe. The results show the sensitivity of electrode separation lead to change the plasma parameters. Furthermore, the surface morphology of gold coated samples at different electrode separation and sputtering current were studied by atomic forc

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Dec 15 2025
Journal Name
Amecj
Rapid analysis and separation of fifteen beta-lactam drugs using reversed-phase high-performance liquid chromatography
...Show More Authors

Beta-lactam medications are among the commonly used antibiotics. These drugs kill germs by disrupting cell wall formation. This drug treats bacterial infections in numerous body sections. A new, quick, high-performance liquid chromatography approach has been developed and verified by the FDA and EMA for the simultaneous estimation of drugs in their medicinal and pure forms. This study deals with the determination of beta-lactam drugs (Amoxicillin, Ampicillin, Cephalexin, Cefotaxime, Cefoxitin, Cefamandole, Cephalothin, Piperacillin, Penicillin, Oxacillin, Cloxacillin, Nafcillin, Carbenicillin, Mezlocillin, Dicloxacillin) by a Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) technique based on an UV detector using a

... Show More
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Mon Jun 22 2020
Journal Name
Baghdad Science Journal
Splitting the One-Dimensional Wave Equation. Part I: Solving by Finite-Difference Method and Separation Variables
...Show More Authors

In this study, an unknown force function dependent on the space in the wave equation is investigated. Numerically wave equation splitting in two parts, part one using the finite-difference method (FDM). Part two using separating variables method. This is the continuation and changing technique for solving inverse problem part in (1,2). Instead, the boundary element method (BEM) in (1,2), the finite-difference method (FDM) has applied. Boundary data are in the role of overdetermination data. The second part of the problem is inverse and ill-posed, since small errors in the extra boundary data cause errors in the force solution. Zeroth order of Tikhonov regularization, and several parameters of regularization are employed to decrease error

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Feb 05 2017
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE OPTIMUM CONDITIONS FOR THE REMOVAL OF HEAVY METAL ELEMENTS FROM AQUEOUS SOLUTIONS USING CONTAMINATED BACTERIA Bacillus subtilis LOCALLY ISOLATED: STUDY THE OPTIMUM CONDITIONS FOR THE REMOVAL OF HEAVY METAL ELEMENTS FROM AQUEOUS SOLUTIONS USING CONTAMINATED BACTERIA Bacillus subtilis LOCALLY ISOLATED
...Show More Authors

We studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1

... Show More
View Publication Preview PDF