Preferred Language
Articles
/
whY5LIcBVTCNdQwCWzuh
Optimum Separation Pressure for Heavy Oils Sequential Separation
...Show More Authors
Abstract<p>The estimation of quantity of liquid that is collected from gas/oil separation system is a very complex task because it requires the application of the flash calculations which needs to solve the cubic equation of state and to use some numerical techniques. These difficulties can be overcome by a computer model which requires a lot of experimental data, long time, and experience.</p><p>This paper adopts a new technique to simplify this problem. It suggests new correlations for optimum separator pressure for separation station of heavy oils. The correlations have been achieved for two- and three- stage separation systems.</p><p>The correlations have been created depending on many Iraqi oil samples. The optimum separator pressure of each individual separator was found at the maximum amount of liquid recovered with the minimum oil formation volume factor.</p><p>The Optimum Separator Soave – Redlich – Kwong model (OSSRK) has been adopted to estimate the optimum separator pressure, while the objective functions, like oil formation volume factor, are predicted by Separator Flash Soave – Redlich – Kwong model (SFSRK) (Hassan 2004).</p><p>The optimum separator pressures have been correlated with mole percent of hexane plus in the well stream fluid, mole percent of methane in the well stream fluid, temperature of the separator and the optimum pressure of the previous separator. Nonlinear multiple regression analysis has been applied to get the best correlation for each system.</p><p>Many statistical tests are used to check the validity of the proposed correlations.</p><p>The error percents of API, GOR, Bo between the optimal cases for each model and the relevant correlations show a maximum of 0.047%, 0.3% and 0.15% for two – stage systems, and 0.2%, 0.6% and 0.22% for three – stage systems. Also the cross plot method is applied to test the correlation validity. These checks are good indication to use these correlations with high degree of confidence.</p>
Scopus Crossref
View Publication
Publication Date
Mon Sep 23 2019
Journal Name
Baghdad Science Journal
New Approach for Solving Three Dimensional Space Partial Differential Equation
...Show More Authors

This paper presents a new transform method to solve partial differential equations, for finding suitable accurate solutions in a wider domain. It can be used to solve the problems without resorting to the frequency domain. The new transform is combined with the homotopy perturbation method in order to solve three dimensional second order partial differential equations with initial condition, and the convergence of the solution to the exact form is proved. The implementation of the suggested method demonstrates the usefulness in finding exact solutions. The practical implications show the effectiveness of approach and it is easily implemented in finding exact solutions.

       Finally, all algori

... Show More
View Publication Preview PDF
Scopus (27)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Investigation of Moisture Sorption Isotherms for Mefenamic Acid Tablets
...Show More Authors

   The moisture sorption isotherms of Mefenamic acid tablets were investigated by measuring the experimental equilibrium moisture content (EMC) using the static method of saturated salt solutions at three temperatures (25, 35, and 45°C) and water activity range from 0.056 to 0.8434. The results showed that EMC increased when relative humidity increased and the sorption capacity decreased, the tablets became less hygroscopic and more stable when the temperature increased at constant water activity. The sorption curves had a sigmoid shape, type II according to Brunauer’s classification. The hysteresis effect was significant along with the whole sorption process. The results were fitted to three models: Oswin, Smith, and Guggen

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 25 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Characterization of Topical Letrozole Nanoemulsion for Breast Cancer
...Show More Authors

Letrozole (LZL) is a non-steroidal competitive aromatase enzyme system inhibitor. The aim of this study is to improve the permeation of LZL through the skin by preparing as nanoemulsion using various numbers of oils, surfactants and co-surfactant with deionized water. Based on solubility studies, mixtures of oleic acid oil and tween 80/ transcutol p as surfactant/co-surfactant (Smix) in different percentages were used to prepare nanoemulsions (NS). Therefore, 9 formulae of (o/w) LZL NS were formulated, then pseudo-ternary phase diagram was used as a useful tool to evaluate the NS domain at Smix ratios: 1:1, 2:1 and 3:1.

View Publication Preview PDF
Scopus (15)
Crossref (6)
Scopus Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
A Comparative Study for Estimate Fractional Parameter of ARFIMA Model
...Show More Authors

      Long memory analysis is one of the most active areas in econometrics and time series where various methods have been introduced to identify and estimate the long memory parameter in partially integrated time series. One of the most common models used to represent time series that have a long memory is the ARFIMA (Auto Regressive Fractional Integration Moving Average Model) which diffs are a fractional number called the fractional parameter. To analyze and determine the ARFIMA model, the fractal parameter must be estimated. There are many methods for fractional parameter estimation. In this research, the estimation methods were divided into indirect methods, where the Hurst parameter is estimated fir

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Design and manufacturing of supercritical drying autoclave for aerogel production
...Show More Authors

This article will address autoclave design considerations and
manufacturing working with high pressure low temperature
supercritical drying technique to produce silica aerogel. The design
elects carbon dioxide as a supercritical fluid (31.7 oC and 72.3 bar).
Both temperature and pressure have independently controlling
facility through present design. The autoclave was light weight (4.5
kg) and factory-made from stainless steel. It contains a high pressure
window for monitoring both transfer carbon dioxide gas to liquid
carbon dioxide and watching supercritical drying via aerogel
preparation process. In this work aerogel samples were prepared and
the true apparent densities, total pore volume and pore size

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Fabrication and characterization of n- InSb Heterojunction for optoelectronic device
...Show More Authors

View Publication
Scopus (10)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sat Apr 05 2025
Journal Name
2025 Ieee 4th International Conference On Computing And Machine Intelligence (icmi)
From Pixels to Diagnosis: AI-Powered CNN for Pneumonia Detection
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
DNA Encoding and STR Extraction for Anomaly Intrusion Detection Systems
...Show More Authors

View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Fabricated of Cu Doped ZnO Nanoparticles for Solar Cell Application
...Show More Authors

Copper with different concentrations doped with zinc oxide nanoparticles were prepared from a mixture of zinc acetate and copper acetate with sodium hydroxide in aqueous solution. The structure of the prepared samples was done by X-ray diffraction, atomic force microscopy (AFM) and UV-VIS absorption spectrophotometer. Debye-Scherer formula was used to calculate the size of the prepared samples. The band gap of the nanoparticle ZnO was determined by using UV-VIS optical spectroscopy.

View Publication Preview PDF
Scopus (17)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Sep 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Permeability Estimation for Carbonate Reservoir (Case Study/ South Iraqi Field)
...Show More Authors

 

   The heterogeneity nature of carbonate reservoirs shows sever scattering of the data, therefore, one has to be cautious in using the permeability- porosity correlation for calculating permeability unless a good correlation coefficient is available. In addition, a permeability- porosity correlation technique is not enough by itself since simulation studies also require more accurate tools for reservoir description and diagnosis of flow and non-flow units.

Evaluation of reservoir characterization  was conducted by this paper for Mishrif Formation in south Iraqi oil field (heterogeneous carbonate reservoir), namely the permeability-porosity correlation, the hydraulic units (HU’s) an

... Show More
View Publication Preview PDF
Crossref (4)
Crossref