Preferred Language
Articles
/
wRaOVocBVTCNdQwCMEar
The effect of background argon gas pressure on parameters of plasma produced by Dc- glow discharge
...Show More Authors

Non-thermal plasmas have become popular as plasma technology has advanced in various fields, including waste management, aerospace technology, and medicinal applications. They can be used to replace combustion fuels in stationary hall motors and need little effort to keep running for longer periods of time. To improve overall system performance, non-reactive gases such as )Xe, Ar, and Kr) are utilized in pure or mixed form to generate plasma. Since DC glow discharge is a fundamental topic of importance, these gases have been researched. The paper concentrates on 2-D modeling and simulation. DC glow-discharge tubes are utilized with argon gas to create plasma and learn about its properties. The magnitude of the electron density, increases with rising pressure, whilst the rest of the parameters gradually decrease with increasing pressure

Publication Date
Mon Sep 01 2025
Journal Name
Journal Of Oral Biology And Craniofacial Research
Morphological & chemo mechanical analysis of exposed cervical dentin treated with three different desensitizing pastes (comparative in vitro study)
...Show More Authors

Background Obstructing dentinal tubules is a valuable approach for managing dentin hypersensitivity. Although various agents promote dentin remineralization, direct comparisons between theobromine, bioactive glass (BAG), and nano-hydroxyapatite (Nano-HAP) under simulated oral conditions remain limited. To fill this gap, this in vitro study aimed to evaluate and compare the effectiveness of these three treatments on exposed cervical dentin. The assessment focused on their chemical, morphological, and mechanical effects on dentin. Materials and methods Forty-eight human dentin slabs were obtained from the cervical portions of twelve sound premolar teeth. Baseline Raman spectroscopy and VMH tests were done to exclude outliers. All specimens we

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Apr 29 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Cyclic Fatigue Resistance of Wave One Gold, F6 SkyTaper, One Curve, and AF Blue R3 NiTi Rotary Instrumentation Systems
...Show More Authors

Objective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to frac

... Show More
Scopus (1)
Scopus
Publication Date
Mon May 31 2021
Journal Name
Journal Of Research In Medical And Dental Science
A Stereomicroscopic Evaluation of Four Endodontic Sealers Penetration into Artificial Lateral Canals Using Gutta-Percha Single Cone Obturation Technique
...Show More Authors

A Stereomicroscopic Evaluation of Four Endodontic Sealers Penetration into Artificial Lateral Canals Using Gutta-Percha Single Cone Obturation Technique, Omar Jihad Banawi*, Raghad

View Publication Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
New sensitive turbidimetric method for determination of losartan potassium in pharmaceutical formulations using flow injection combined with homemade turbidimeter
...Show More Authors

Scopus
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
CDD Study of Charge Density Distributions and Elastic Electron Scattering Cross Sections for some Stable Nuclei: Charge Density Distributions
...Show More Authors

paper

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 21 2014
Journal Name
International Journal Of Antennas And Propagation
Development of a Compact Wide-Slot Antenna for Early Stage Breast Cancer Detection Featuring Circular Array Full-View Geometry
...Show More Authors

A novel planar type antenna printed on a high permittivity Rogers’ substrate is proposed for early stage microwave breast cancer detection. The design is based on a p-shaped wide-slot structure with microstrip feeding circuit to eliminate losses of transmission. The design parameters are optimized resulting in a good reflection coefficient at −10 dB from 4.5 to 10.9 GHz. Imaging result using inhomogeneous breast phantom indicates that the proposed antenna is capable of detecting a 5 mm size cancerous tumor embedded inside the fibroglandular region with dielectric contrast between the target and the surrounding materials ranging from 1.7 : 1 to 3.6 : 1.

Publication Date
Tue Oct 04 2022
Journal Name
Azerbaijan Medical Journal
Ultrasonic fetal Doppler and growth indices and their relation to immediate neonatal outcomes in different severities of maternal anemia
...Show More Authors

Doppler assessment may lead to intervention that reduces the risk of fetal brain damage. Aim of thestudy: to assess the relation between ultrasonic hemodynamic Doppler indices of middle cerebral and umbilical arteries (PI, RI), growth indices to immediate neonatal outcomes (weight, head & abdominal circumference, APGAR scores at 1 and 5 minutes and neonatal unit admission) in women with mild, moderate and severe anemia during pregnancy. Present study is a clinical prospective study carried out in Al-Elwiya Maternity Teaching Hospital during (January-Jun) 2019, all anemic pregnant women presented to Obstetrical wards in hospitals for emergency cesarean section were the study population. The final sample selected was 120 pregnant women. Ultra

... Show More
Publication Date
Mon Jun 08 2020
Journal Name
Research Journal Of Chemistry And Environment
High Performance Liquid Chromatographic and Areaunder Curve spectrophotometric Methods forEstimation of Cefixime in Pure and MarketedFormulation: A Comparative Study
...Show More Authors

Cefixime is an antibiotic useful for treating a variety ofmicroorganism infections. In the present work, tworapid, specific, inexpensive and nontoxic methods wereproposed for cefixime determination. Area under curvespectrophotometric and HPLC methods were depictedfor the micro quantification of Cefixime in highly pureand local market formulation. The area under curve(first technique) used in calculation of the cefiximepeak using a UV-visible spectrophotometer.The HPLC (2nd technique) was depended on thepurification of Cefixime by a C18 separating column250mm (length of column) × 4.6 mm (diameter)andusing methanol 50% (organic modifier) and deionizedwater 50% as a mobile phase. The isocratic flow withrate of 1 mL/min was applied, the temper

... Show More
Publication Date
Wed Jan 02 2019
Journal Name
Journal Of The College Of Languages
Функциональная транспозиция причастий в прилагательное Functional Shift of Present and Past Participles from No-minal Meaning to Adjectival Meaning
...Show More Authors

View Publication
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Iraqi Journal Of Applied Physics
Fabrication of Solid Random Gain Media in Visible Region From Rhodamine Dye Solutions Containing Highly-Pure Titanium Dioxide Nanoparticles
...Show More Authors

In this work, solid random gain media were fabricated from laser dye solutions containing nanoparticles as scattering centers. Two different rhodamine dyes (123 and 6G) were used to host the highly-pure titanium dioxide nanoparticles to form the random gain media. The spectroscopic characteristics (mainly fluorescence) of these media were determined and studied. These random gain media showed laser emission in the visible region of electromagnetic spectrum. Fluorescence characteristics can be controlled to few nanometers by adjusting the characteristics of the host and nanoparticles as well as the preparation conditions of the samples. Emission of narrow linewidth (3nm) and high intensity in the visible region (533-537nm) was obtained.

View Publication Preview PDF