Background: The best material for dental implants is polyetherketoneketone (PEKK). However, this substance is neither osteoinductive nor osteoconductive, preventing direct bone apposition. Modifying the PEKK with bioactive elements like strontium hydroxyapatite is one method to overcome this (Sr-HA). Due to the technique's capacity to provide better control over the coating's properties, RF magnetron sputtering has been found to be a particularly useful technique for deposition. Materials and methods : With specific sputtering conditions, the RF magnetron technique was employed to provide a homogeneous and thin coating on Polyetherketoneketone substrates.. the coatings were characterized by Contact angle, adhesion test, X-ray diffraction (XRD), atomic force microscope and Elemental Analysis with Energy Dispersive X-Ray (EDX) Results : indicated that strontium hydroxyapatite had successfully deposited onto the surface with significant improvement in the wettability value to provide a suitable environment for cell attachment, spreading, proliferation, and differentiation Conclusion: Coating PEKK with RF magnetron sputtering can provide homogeneous surfaces laying the groundwork for improving PEKK's potential bioactivity, such as surface wettability. Wetting qualities are critical in implantable materials and are used to predict future osseointegration success.
The research aimed to know the effect of the Parashot strategy in developing the reading comprehension skills of first-grade intermediate students in reading. The researchers put the following two null hypotheses: There is no statistically significant difference at the level (0.05) between the average scores of the experimental group students who study the subject Reading with the Parashot strategy in the pre and post-tests in developing reading comprehension skills as a whole. There is no statistically significant difference at the level (0.05) between the average scores of the experimental group students who study the reading material using the Parashot strategy and the average scores of the control group students who study the same subje
... Show MoreDensity functional theory (DFT) with B3LYP level and 6-311G[Formula: see text] basis sets for light atoms like N and O and SDD basis sets for heavy atoms like Sn is used to examine the interaction of tin dioxide nanocrystals with nitrogen dioxide as a function of temperature from 273[Formula: see text]K to 373[Formula: see text]K through a Gaussian 09W software program. Gibbs free energy, enthalpy, and entropy of activation and reaction are calculated. The situation of transition of SnO2 clusters toward nitrogen dioxide is investigated. According to the findings, the activation energy of SnO2 clusters with nitrogen dioxide increases as the temperature rises (in negative value). Gauss view 0
... Show MoreThe importance of the study lies in highlighting the role of smartwatches as a modern tool for analyzing training load based on functional indicators, such as heart rate and calorie consumption. This allows coaches to monitor individual players’ responses during different training periods, helping to improve physical performance efficiency and reduce the risk of overload-induced fatigue. The study aimed to analyze calorie consumption at different heart rate levels between the special preparation and competition periods for youth football players, with the goal of determining the effect of physiological adaptation on energy efficiency. To achieve this objective, the researcher adopted the descriptive method due to its suitability f
... Show MoreA batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92
... Show MoreLithium-rich layered oxide cathodes have attracted considerable attention due to their high energy density, but have suffered from voltage drop, structural instability, and limited electrical conductivity. In this study, the electrochemical performance of the lithium-rich cathode material Li[Li0.20Mn0.54Ni0.13Co0.13]O2 was evaluated after modification by zinc doping and composition with graphene oxide or graphene. The zinc-doped powders were synthesized by the sol-gel method, while the graphene-based composites were prepared by the hydrothermal route. The structural, morphological and electrochemical characteristics of the modified materials were examined using X-ray diffraction, Fourier transform infrared spectroscopy, field emission scann
... Show MoreAim of the study: Using surface roughness and tensile bond strength tests, the objective of this investigation was to ascertain the impact of laser surface modification on the binding strength of injectable thermoplastic acrylic denture base material to acrylic-based soft-liner material. Materials and methods: Acrylic base soft liner material was bonded to injectable thermoplastic acrylic resin (Deflex). Forty specimens were created (20 disc, 20 dumbbells) 10 of each specimen type as control specimens, and 10 were treated with nano pulse Nd: YAG laser. The data were analyzed using the Kruskal-Wallis test and unpaired t-test (a=.05) and the roughness test was performed utilizing a double column universal test machine. Results: Compar
... Show MoreIn this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively