Preferred Language
Articles
/
wBiSapUBVTCNdQwCiy1T
Assessment of the bypass of obturation materials beyond fractured instruments after using different obturation techniques in simulated curved canals (An in-vitro study)
...Show More Authors

This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.5 mm, prepared to an ISO #15 diameter and taper. Canals were shaped using ProTaper Universal files (Dentsply Maillefer) attached to an X-smart Plus endo motor (Dentsply), set at 3.5 Ncm torque and 250 rpm, up to size S2 at working length. To simulate fractures, F2 and F3 files were weakened 3 mm from the tip, then twisted to break in the apical and middle sections of the canal, respectively. All samples were sealed with GuttaFlow 2 and divided into three groups (n = 20/group) according to obturation technique: A) single cone, B) lateral condensation with a rotary spreader, and C) softcore obturators. Each group was then divided into two subgroups (n = 10) based on the instrument fracture location (1 = apical, 2 = middle). The linear intrusion of obturation materials through the fractured instruments was measured using ImageJ software and analyzed statistically with ANOVA, Tukey tests, and independent t-tests, with significance set at p<0.05. Material bypass in group B1 (3.27 ± 0.63 mm) was significantly greater than in group A1 (2.39 ± 0.44 mm) and group C1 (2.91 ± 0.77 mm). In group C2, bypass (5.76 ± 0.64 mm) was significantly higher than in group A2 (3.82 ± 0.2 mm) and group B2 (2.27 ± 0.96 mm). Additionally, bypass in group A2 was greater than in group B2, and group B1 had more bypass than B2, while group C2 exceeded C1. The lateral condensation technique with a rotary spreader and softcore obturators increased the bypass of obturation materials through fractured instruments in simulated curved canals. These techniques may thus enhance material flow in endodontic procedures involving instrument fractures.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Jun 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Improvement the corrosion Behavior of Titanium by Nanotubular Oxide in a simulated saliva solution
...Show More Authors
Abstract<p>The corrosion behavior of Titanium in a simulated saliva solution was improved by Nanotubular Oxide via electrochemical anodizing treatment using three electrodes cell potentiostat at 37°C. The anodization treatment was achieved in a non-aqueous electrolyte with the following composition: 200mL ethylene glycol containing 0.6g NH4F and 10 ml of deionized water and using different applied directed voltage at 10°C and constant time of anodizing (15 min.). The anodized titanium layer was examined using SEM, and AFM technique.</p><p>The results showed that increasing applied voltage resulted in formation titanium oxide nanotubes with higher corrosion resistance </p> ... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Crossref
Publication Date
Tue Nov 26 2019
Journal Name
Journal Of Engineering
The Experimental Assessment of R134a and Its Lower GWP Alternative R1234yf in an Automobile Air Conditioning System
...Show More Authors

Reducing global warming potential (GWP) of refrigerants is needed to the decrease of ozone-depleting of refrigeration systems leakages. Refrigerant R1234yf is now used to substitute R134a inside mobile air conditioning systems. Thermodynamic properties of R1234yf are similar to R134a. Also, it has a very low GWP of 4, compared to 1430 for R134a, making it a proper choice for future automobile refrigerants. The purpose of this research is to represent the main operating and performance differences between R1234yf and R134a. Experimental analysis was carried out on the automotive air conditioning system (AACS) with 3 kW nominal capacity, to test and compare the performance of R134a with R1234yf. Experiments were accomplish

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Dental Hypotheses
Comparative Evaluation of Marginal Microleakage Between Bulk-Fill, Preheated Bulk-Fill, and Bulk-Fill Flowable Composite Resins Above and Below Cemento-Enamel Junction Using Micro-Computed Tomography: An In Vitro Study
...Show More Authors

Objective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Mar 18 2018
Journal Name
Mustansiria Dental Journal
The Effect of Pepsi Cola Beverage on Surface Roughness of Two Composite Resins (In Vitro study)
...Show More Authors

An acidic environment causes surface changes of resin composites. Filler particlesize and filler distribution also have a direct effect on these surface changes. This invitro study evaluated the influence of Pepsi Cola drink on the surface roughness ofComposan LCM and Composan Ceram over time. Sixteen disc shaped specimens(10mm diameter, 2mm thickness) of each resin composite were fabricated, therebyforming two groups (n= 8). Surface roughness (Ra) was analyzed after 24 hrs beforeexposure to beverage. The specimens were submitted to a five minutes immersion inPepsi Cola three times daily interrupted by immersion in deionized distilled water (37C˚). Surface roughness measurements were done at 10, 30, and 60 days intervals. Datawere

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Study the role of auxins and sytoknins on in vitro propagation of Spilanthes acmella (L.) Murr
...Show More Authors

The technique of plant tissue culture has been used to In vitro micropropagation of Spilanthes acmella (L.) Murr. It is an ornamental and medicinal plant not cultivated in Iraq. Seeds were sterilized and cultuared on full strength Murashige and Skoog medium(1962)(MS). Naphthalene acetic acid (NAA), 6- furfuryl aminopurine (Kin.) growth regulators were used at the Initiation stage.The combination between IAA and Kin. was used in multiplication stage. IAA was used for rooting the shoots. Results showed that 1.5% sodium hypochlorite for 15 min was very effective for disinfecting and survival. Nodes exhibited relatively highest response as compared with apical meristems and leaflets culture. Supplying the culture medium with 1 mg/L.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Study the Characterizations of Cement Mortar by Nano Pozzolanic Materials Additions
...Show More Authors

This study involves adding nano materials and interaction with cement mortar behavior for several mortar samples under variable curing time with constant water to cement ratio (W/C = 0.5). The effects of adding nano materials on the microstructure of cement mortar were studied by (Scanning Electronic Microscopy (SEM) and X-Ray (for samples at different curing time 28 and 91 days. Small ratio replacements of nano particles (SiO2 or Al2O3) were added to Ordinary Portland Cement (OPC) type (I). The percentage of nano materials additives replacement by weight of ordinary Portland cement includes (1, 2, 3, 4 and 5%) for both types of nano materials with constant (W/C) ratio, also the amount of the fin

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Sep 03 2009
Journal Name
Engineering And Technology Journal
Study on the properties of composite materials produced by centrifugal casting
...Show More Authors

سمير خلف فياض * و محسن طالب د.نوال عزت عبد اللطيف*, مجلة الهندسة والتكنولوجيا, 2010

View Publication Preview PDF
Publication Date
Mon Apr 04 2022
Journal Name
Journal Of Research In Medical And Dental Science
Efficacy of Varnishes with: Bioactive Glass, Recaldent Technology and Silver Diamine Fluoride in Comparison with Sodium Fluoride on Tooth Surface Micro-hardness (an In Vitro Study)
...Show More Authors

Efficacy of Varnishes with: Bioactive Glass, Recaldent Technology and Silver Diamine Fluoride in Comparison with Sodium Fluoride on Tooth Surface Micro-hardness (an In Vitro Study)

View Publication Preview PDF
Publication Date
Sat Feb 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
How geometric reverse engineering techniques can conserve our heritage; a case study in Iraq using 3D laser scanning
...Show More Authors
Abstract<p>Laser scanning has become a popular technique for the acquisition of digital models in the field of cultural heritage conservation and restoration nowadays. Many archaeological sites were lost, damaged, or faded, rather than being passed on to future generations due to many natural or human risks. It is still a challenge to accurately produce the digital and physical model of the missing regions or parts of our cultural heritage objects and restore damaged artefacts. The typical manual restoration can become a tedious and error-prone process; also can cause secondary damage to the relics. Therefore, in this paper, the automatic digital application process of 3D laser modelling of arte</p> ... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Automatic Determination of Liquid's Interface in Crude Oil Tank using Capacitive Sensing Techniques
...Show More Authors

The petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa

... Show More
View Publication Preview PDF
Crossref