Green areas are an essential component of city planning, as they serve as an outlet for them to spend their free time, in addition to the environmental role that these green areas play in improving the city’s climate by purifying the air and beautifying the city. The study’s problem is summarized in identifying the appropriateness of the current spatial distribution of green areas in the city of Najaf with the current population densities and the pattern in which green areas are distributed using GIS and knowing the per capita share of those green areas in the city, the research assumes that the inconsistency of spaces between regions Green and residential neighbourhoods need to conform to the standards for the individual share. The research also aims to know the reality of the green areas in the holy city of Najaf using GIS to take advantage of the capabilities provided by the program in the field of entering and analysing information related to its spatial distribution, as well as identifying the pattern in which the green areas are distributed in the city of Najaf, and come up with recommendations and proposals to address the existing imbalance. The research found that more than half of the neighbourhoods in the region do not conform to the standard followed in assessing the individual’s share, where the individual’s share ranged between (0.4-3.9) square meters, and there are neighbourhoods completely devoid of green areas, and this is due to poor planning in those areas. On the neighbourhood link index, the pattern of distribution of these green areas was aggregated to random. As for the Moran coefficient, its value departed from one frequently, indicating a weak spatial and random correlation of green areas, The area reached by the impact area of the green areas reached (5512) hectares, which is equivalent to (83.32%) of the total area of the Holy City of Najaf, and the neighbourhoods near the middle centre and surrounding it are the most intersecting neighbourhoods in the impact area.
This research deals with the design and simulation of a solar power system consisting of a KC200GT solar panel, a closed loop boost converter and a three phase inverter by using Matlab / Simulink. The mathematical equations of the solar panel design are presented. The electrical characteristics of the panel are tested at the values of 1000 for light radiation and 25 °C for temperature environment. The Proportional Integral (PI) controller is connected as feedback with the Boost converter to obtain a stable output voltage by reducing the oscillations in the voltage to charge a battery connected to the output of the converter. Two methods (Particle Swarm Optimization (PSO) and Zeigler- Nichols) are used for tuning
... Show MoreThe doping process with materials related to carbon has become a newly emerged approach for achieving an improvement in different physical properties for the obtained doped films. Thin films of CuPc: C60 with doping ratio of (100:1) were spin-coated onto pre-cleaned glass substrates at room temperature. The prepared films were annealed at different temperatures of (373, 423 and 473) K. The structural studies, using a specific diffractometry of annealed and as deposited samples showed a polymorphism structure and dominated by CuPc with preferential orientation of the plane (100) of (2θ = 7) except at temperature of 423K which indicated a small peak around (2θ = 3
Objective: To assess the Impact of Socio-economic status on age at menarche among secondary school students at
AL-Dora city in Baghdad, Iraq.
Methodology: This is a cross sectional study with multi-stage sampling was carried out during the period from the
3
th of December2013 to 12th of March 2014. The Sample comprised of 1760 girls, 1510 girls from urban area and
250 from rural area was included in the study. In first stage, selection of schools was done, and one class was
selected randomly from each level of Education, The data collection through a special questionnaire which Contain
the age of girl by year, class level, birth order, number of household, number of rooms, residency (urban/rural),
education level
Hypertension is a major health problem throughout the world because of its high prevalence and its association with increased risk of cardiovascular diseases. It is defined as systolic blood pressure ≥ 140 mmHg and/or diastolic blood pressure ≥ 90 mmHg. The aim of this study was to compare the efficacy, safety and cardiovascular disease risk lowering ability, of three antihypertensive drug regimens.
A retrospective study was carried out on 66 hypertensive patients, divided in to three groups based on their antihypertensive drug regimens (ACE inhibitors, β-blockers treated and combination antihypertensive therapy, the combination therapy consist of two or more of the following antihypertensive drugs ACE inhibitor di
... Show MoreBackground: Early detection of subclinical left ventricular (LV) systolic dysfunction is crucial and could influence patients' prognosis by aiding the clinician to candidate patients for better management.
Objective: To detect early LV systolic dysfunction in asymptomatic patient with chronic aortic regurgitation by two dimensional speckle tracking echocardiography.
Methods: Sixty one asymptomatic patients with chronic aortic regurgitation, with no ischemic heart diseases (by coronary angiography) or conductive heart diseases, no diabetes mellitus, no hypertension, and no other valvular heart diseases (group 1) and fifty age and sex-matched healthy subjects (
... Show MoreThe current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l
... Show MoreCoupling reaction of 2-amino benzoic acid with 8-hydroxy quinoline gave bidentate azo ligand. The prepared ligand has been identified by Microelemental Analysis,1HNMR,FT-IR and UV-Vis spectroscopic techniques. Treatment of the prepared ligand with the following metal ions (ZnII,CdII and HgII) in aqueous ethanol with a 1:2 M:L ratio and at optimum pH, yielded a series of neutral complexes of the general formula [M(L)2]. The prepared complexes have been characterized by using flame atomic absorption, (C.H.N) Analysis, FT-IR and UV-Vis spectroscopic methods as well as conductivity measurements. The nature of the complexes formed were studied following the mole ratio and continuous variation methods, Beer's law obeyed over a concentration range
... Show MoreNew simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l. mole1. cm-1 and Sandel’s index 0.0449 μg. cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg. ml-1 with relative standard deviation percent (RSD%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five
... Show More