he Orthogonal Frequency Division Multiplexing is a promising technology for the Next Generation Networks. This technique was selected because of the flexibility for the various parameters, high spectral efficiency, and immunity to ISI. The OFDM technique suffers from significant digital signal processing, especially inside the Inverse/ Fast Fourier Transform IFFT/FFT. This part is used to perform the orthogonality/De-orthogonality between the subcarriers which the important part of the OFDM system. Therefore, it is important to understand the parameter effects on the increase or to decrease the FPGA power consumption for the IFFT/FFT. This thesis is focusing on the FPGA power consumption of the IFFT/FFT uses in the OFDM system. This research finds a various parameters effect on FPGA power of the IFFT/FFT. In addition, investigate the computer software used to measure and analyse the FPGA power consumption of OFDM transceivers, and selects the target hardware used in the computer software. The researched parameters include the number of bits used in calculating the phase factor precision; Cyclic Prefix length effected on IP core IFFT, Subcarrier modulation type, word length width, Real and Complex Value IFFT, IFFT length, and subcarriers sampling frequency. The real value IFFT is proposed in 1987 and implemented in this thesis. These parameters above are discussed by comparing the result between the Real and Complex value IFFT used inside the OFDM system.
Results of exposure larvae of the most important predator in the integrated pest management , the green lacewings, Chrysoperla carnea (Stephens) to various densities of fig moth Ephestia cautella eggs showed increasing in the number of consumed prey at decreasing rate of increasing prey density where curve slope consumption decreased gradually until leveling off. These specifications concurred with type II functional response that predators appear towards varied densities of its preys ,that was confirm by logistic regression between the proportion of prey eaten in relation to prey offered . Third larval instars of the predator showed attack rate (a) of 4.85. This was greater than the second larval instar (3.58). Handling time (Th) per
... Show MoreThe research involved a rapid, automated and highly accurate developed CFIA/MZ technique for estimation of phenylephrine hydrochloride (PHE) in pure, dosage forms and biological sample. This method is based on oxidative coupling reaction of 2,4-dinitrophenylhydrazine (DNPH) with PHE in existence of sodium periodate as oxidizing agent in alkaline medium to form a red colored product at ʎmax )520 nm (. A flow rate of 4.3 mL.min-1 using distilled water as a carrier, the method of FIA proved to be as a sensitive and economic analytical tool for estimation of PHE.
Within the concentration range of 5-300 μg.mL-1, a calibration curve was rectilinear, where the detection limit was 3.252 μg.mL
Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M
... Show MoreThe fluorescence emission of Rhodamine 6G (R6G) and Acriflavine dyes in PMMA polymer have been studied by changing the irradiation and exposure time of laser light to know the effect of this parameter. It was found that the fluorescence intensity decreases in the polymer samples doped dyes as the exposure time increases and then reaches stabilization at long times, this behavior called photobleaching, which have been shown in liquid phase less than solid phase. Using 2nd harmonic with wavelength 530 nm laser, the photobleaching effect in the two dye-doped polymers different solvent but same was studied. It was observed that photobleaching of by different solution and by using dip spin coating the photobleaching seem in liquid phase more
... Show More