Asthma is a chronic inflammatory disorder of the airways in which many cells and cellular elements play a role. The treatment guidelines recommend theuse of a second controller drug in addition to medium doses of inhaled corticosteroids (ICSs) rather than the use of high doses ICS alone in the treatment of moderate-severe persistent asthma. This study was conducted to compare the clinical efficacy and safety of three treatment regimens in Iraqi patients with moderate-severe persistent asthma.The study included three groups; each group included 15 patients. Patients were administered beclomethasone inhaler alone 1500-2000 μg/day, beclomethasone inhaler 750-1000 μg/day plus oral controlled release aminophylline tablets 450 mg/day or beclomethasone inhaler 750-1000 μg/dayplus oral montelukast tablets 10 mg/day for 4-5 weeks. Patients were followed 2 weeks and 4-5 weeks after the baseline visit. In all of the three groups,significant improvements were noticed in pulmonary function test parameters (FEV1, FVC, FEF50%) and the asthma symptom records (day-time symptoms,night-time symptoms, number of salbutamol puffs per 24 hours), while there were no significant differences among the groups. Regarding side effects, onlythe group of inhaled steroid plus aminophylline tablets showed discontinuation of drug therapy in some patients which could be attributed to the development of serious side effects.It was concluded that the administration of a second controller agent was important to use lower doses of inhaled beclomethasone. It was concluded alsothat montelukast was associated with a lower incidence of serious side effects than aminophylline which could make aminophylline an alternative to montelukast as combination therapy with medium doses ICS in the treatment of moderate-severe persistent asthma
Background :Evening preparation for colonoscopy is often unsatisfactory and inconvenient. This study was performed to compare the efficacy of bowel preparation at two different timings: night before and morning of endoscopy and to compare the cecal intubation rate and disturbance of sleep hours between these two groups.
Methods: In this prospective randomized endoscopist- blinded trial, 150 patients were enrolled between March 2010 and August 2011. Patients aged between 18 to 80 years needing colonoscopy were included. Patients with prior bowel surgery, suspected bowel obstruction or those who didn't completely fulfill the preparation instructions were excluded. Patients received polyethyelen glycol electrolyte preparation in a mornin
The covid-19 pandemic sweeping the world and has rendered a large proportion of the workforce as they are unable to commute to work. This has resulted in employees and employers seeking alternative work arrangements, including the software industry. Then comes the need for the global market and international presence of many companies to implement the global virtual teams (GVTs). GVTs members are gradually engaged in globalized business environments across space, time and organizational boundaries via information and communication technologies. Despite the advancement of technology, the project managers are still facing many challenges in communication. Hense, to become a successful project manager still a big challenge for them. This study
... Show MoreThis work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem
... Show MoreThe best proximity point is a generalization of a fixed point that is beneficial when the contraction map is not a self-map. On other hand, best approximation theorems offer an approximate solution to the fixed point equation . It is used to solve the problem in order to come up with a good approximation. This paper's main purpose is to introduce new types of proximal contraction for nonself mappings in fuzzy normed space and then proved the best proximity point theorem for these mappings. At first, the definition of fuzzy normed space is given. Then the notions of the best proximity point and - proximal admissible in the context of fuzzy normed space are presented. The notion of α ̃–ψ ̃- proximal contractive mapping is introduced.
... Show MoreA field study was conducted in Al-Khalis district, Diyala Governorate in 2019 to test the sensitivity of three varieties of pepper to the population density of the whitefly B. tabaci, Anaheim pepper, Aleppo and local variety, and the results showed that the Anaheim variety was the most infested with the whitefly density 4.08 whitefly/ leaf and then the local variety 2.7 whitefly/ leaf. The lowest population density was 1.25 whitefly/ leaf of Aleppo variety. Variety Aleppo also recorded the lowest percentage of whitefly infection B. tabaci of 39.22%, but not have significant differences in the percentage of whitefly infestation, as it reached 53.64% and 54.85% for the Anaheim and local varieties, respectively. The resistance of variety Alepp
... Show MoreThis research describes a new model inspired by Mobilenetv2 that was trained on a very diverse dataset. The goal is to enable fire detection in open areas to replace physical sensor-based fire detectors and reduce false alarms of fires, to achieve the lowest losses in open areas via deep learning. A diverse fire dataset was created that combines images and videos from several sources. In addition, another self-made data set was taken from the farms of the holy shrine of Al-Hussainiya in the city of Karbala. After that, the model was trained with the collected dataset. The test accuracy of the fire dataset that was trained with the new model reached 98.87%.