The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were: number of web openings, the method used to strengthen the member at openings and the height of drop during impact tests. All beams were simply supported with load applied at mid – span. Static results indicated that T-beams with four and six un-strengthened web circular openings whose diameter is 48% of the web depth have strength capacities less than those without openings by 30% and 41%, respectively. However, strengthening of webs results in an increase in the strength capacities ranging between 27% and 92%, depending on the type of strengthening. Impact results indicated that the beam with four openings did not show a remarkable increase in the maximum mid-span deflection compared with the solid beam, while that with six openings showed an increase in the maximum mid-span deflections by about 75% greater than the maximum mid-span deflection of the solid beam. Strengthening of specimens could overcome the increase in deflections.
Abstract
In this study, the effect of carboxylic methyl cellulose (CMC), and sodium dodcyl benzene sulfonate (SDBS) as an aqueous solution on the drag reduction was investigated. Different concentrations of (CMC) and (SDBS) such as (50, 100, 150, 200, 250, 300, 350, 400, 450, and 500 ppm) were used to analyze the aqueous solution properties, including surface tension, conductivity, and shear viscosity. The optimum four concentrations (i.e., 50, 100, 200, and 300 ppm) of fluid properties were utilized to find their effect on the drag reduction. Two different PVC pipe diameters (i.e., 1" and 3/4") were used in this work. The results showed that blending CMC with SDBS gives
... Show MoreThe ciliate species isolated from midgut and hindgut of Rough-tailed gecko Cyrtopodion scabrum (Heyden, 1827), identified as Nyctotherus hardwickii was collected from many regions of Baghdad, Iraq. The current study deals with a description and comparison of the morphology and morphometric characters of this species for the first time in Iraq.
Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o
... Show MoreThis study examined the relationship between the reporting lag (the timeliness of corporate financial reporting) and several independent variables: (1) Audit reporting lag,(2)Company Size,(3) Profitability of the company,(4)Company Age,(5) Sector Type.(6)Audit’s Opinion,(7) Market Type,(8) Gearing,(9) Concentration of ownership,(10) Audit Firm Size(11)Profit or Loss Company(12) Companies Listed lag on the PEX. In order to achieve the objectives of the study and testing its hypotheses, the data Obtained through actual data of a financial reports, and based on me
... Show MoreA fixed firefighting system is a key component of fire safeguarding and reducing fire danger. It is installed as a permanent component in a structure to protect the entire or a portion of the building and its contents. The study aims to review the previous studies that deal with the evaluation of fire safety measures and their use in resolving problems associated with fire threats in buildings. For this reason, a number of previous studies in this field were reviewed compared with the NFPA code. The findings revealed that regulatory developments over the last several decades had created an atmosphere conducive to innovation. This has resulted in a growth in the number of fixed firefighting system types now obtainable. Th
... Show MoreSupervised By : Prof. dr. Shaker Jaseem Mohammed This research aims to identify the (effectiveness of Bayer's strategy in the development of deductive thinking among students in the fifth grade literary material European history) and to achieve the goal set researcher null hypothesis of the following: • There is no statistically significant difference between the average scores of the experimental group which studied the use of Bayer's strategy and the control group, which studied the use of the usual way in the development of deductive reasoning. The study sample consisted of (84 students) of the students in the fifth grade literary breeding Baghdad / Karkh second Directorate for the academic year 2015-2016 were distributed Aanhaldras
... Show MoreThis article presents the simultaneous adsorption of bimetal Cu2+ and Zn2+ from an aqueous solution using activated carbon synthesized from a plum seed precursor by sulfuric acid and microwave activation: plum seeds chemically activated by 45% (w/w) sulfuric acid with 2:1 ratio for 4 h, then carbonized for 2 h at 700 °C and the product obtained activated in a microwave oven for 20 min at 700 W for final of activation. Plum seeds and activated carbon produced were characterized in terms of their physical and chemical composition using Brunauer–Emmett–Teller measurements, field emission scanning electr
The present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.
The best isotherm model for the batch single Cr(III) uptake by ZVI
... Show MoreA newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show More