The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were: number of web openings, the method used to strengthen the member at openings and the height of drop during impact tests. All beams were simply supported with load applied at mid – span. Static results indicated that T-beams with four and six un-strengthened web circular openings whose diameter is 48% of the web depth have strength capacities less than those without openings by 30% and 41%, respectively. However, strengthening of webs results in an increase in the strength capacities ranging between 27% and 92%, depending on the type of strengthening. Impact results indicated that the beam with four openings did not show a remarkable increase in the maximum mid-span deflection compared with the solid beam, while that with six openings showed an increase in the maximum mid-span deflections by about 75% greater than the maximum mid-span deflection of the solid beam. Strengthening of specimens could overcome the increase in deflections.
Objectives: The aim of this study was to assess the possible the association between +3061 (G>A, rs1143676) missense mutation in exon 24 of the integrin α-4 subunit (ITGA-4) gene and the response to natalizumab in a sample of Iraqi multiple sclerosis patients. Methods: A sample of 59 patients with multiple sclerosis (16 males and 43 females; mean age of 32 years; age range of 15 to 52 years) receiving natalizumab for at least 12 consecutive months were involved in the study between March and August/ 2022. The sample was categorized into two groups according to their response to natalizumab treatment (responders and non-responders). Polymerase chain reaction and Sanger’s sequencing for the extracted deoxyribonucleic acid was pe
... Show MoreThe use of external posttensioning technique for strengthening reinforced concrete girders has been considerably studied by many researchers worldwide. However, no available data are seen regarding strengthening full-scale composite prestressed concrete girders with external posttensioned technique under static and repeated loading. In this research, four full-scale composite prestressed I-shape girders of 16 m span were fabricated and tested under static and repeated loading up to failure. Accordingly, two girders were externally strengthened with posttensioned strands, while the other two girders were left without strengthening. The experimental tests include deflection, cracking load, ultimate strength and strains at midspan, a
... Show MoreThis paper presents experimentally a new configuration of shear connector for Steel-Concrete-Steel (SCS) sandwich beams that is derived from truss configuration. It consists of vertical and inclined shear connectors welded together and to cover steel plates infilled with concrete. Nine simply supported SCS beams were tested until the failure under a concentrated central load (three- point bending). The beams were similar in length (1100mm), width (100mm), and the top plate thickness (4mm). The test parameters were; beam thickness (150, 200, 250, and 300mm), the bottom plate thickness (4, and 6mm), the diameter of the shear connectors (10, 12, and 16mm), and the connector spacing (100, 200, and 250mm). The test results sh
... Show MoreTo overcome the problems which associated with the standard multiple daily doses (MDD)
of aminoglycosides (AGs) like high incidence of toxicity(nephrotoxicity, ototoxicity)(5-25%) and high cost, an alternative approach was developed which was single daily dose (SDD).This new regimen was designed to maximize bacterial killing by optimizing the peak concentration/minimum inhibitory concentration(MIC)ratio and to reduce the potential for toxicity. The study includes 75 patients selected randomly, 50 of them received SDD regimen of age range of 17-79 years and the remaining received MDD regimen of age range of 13-71 years. The study was designed to evaluate the safety of SDD regim
... Show MoreIn most Reinforced Concrete (RC) buildings, the cross-section size of rectangular columns that conventionally used in these structures is larger than the thickness of their partitions. Consequently, a part of the column is protruded out of the wall which has some architectural disadvantages. Reducing the column size by using high strength concrete will result in slender column, thus the stability problem may be occurred. The stability problem is difficult to be overcome with rectangular columns. This paper study the effectiveness of using new types of columns called Specially Shaped Reinforced Concrete (SSRC) columns. Besides, the use of SSRC columns provides many structural advantage
Multiple sclerosis (MS) is a chronic, inflammatory demyelinating disease of central nervous system with complex etiopathogenesis that impacts young adults (Lee et al., 2015), and MS impacts younger and middle aged character and leads to a range of disabilities that can alter their daily routines (Yara et al, 2010). Although, the exact cause of MS is still undetermined, the disease is mediated by adaptive immunity through the infiltration of T cells into the central nervous system (Bjelobaba et al, 2017). MS causes the Focal neurological symptomsand biochemical changes in the molecular level and the variation of neural cells such as loss or alteration of sensation, motor function, visible signs such as blurred vision or transient blindness,
... Show MoreThis paper studies the effect of mean wind velocity on tall building. Wind velocity, wind profile and wind pressure have been considered as a deterministic phenomenon. Wind velocity has been modelled as a half-sinusoidal wave. Three exposures have been studied B, C, and D. Wind pressure was evaluated by equation that joined wind pressure with mean wind velocity, air density, and drag coefficient.
Variations of dynamic load factor for building tip displacement and building base shear were studied for different building heights, different mode shapes, different terrain exposures, and different aspect ratios of building plan. SAP software, has been used in modelling and dynamic analysis for all case studies.
... Show More