Preferred Language
Articles
/
vebDsZ0BmraWrQ4drVoZ
User Oriented Calibration Method for Stonex X300 Terrestrial Laser Scanner
...Show More Authors

    Terrestrial laser scanners (TLSs) are 3D imaging systems that provide the most powerful 3D representation and practical solutions for various applications. Hence this is due to effective range measurements, 3D point cloud reliability, and rapid acquisition performance. Stonex X300 TOF scanner delivered better certainty in far-range than in close-range measurements due to the high noise level inherent within the data delivered from Time of Flight (TOF) scanning sensors. However, if these errors are manipulated properly using a valid calibration model, more accurate products can be obtained even from very close-range measurements. Therefore, to fill this gap, this research presents a user-oriented target-based calibration routine to compute the calibration parameters of Stonex X300 TLS. The proposed routine investigates range and angular measurements to mitigate mechanical misalignment error sources of this device. Distance and angular index errors were computed, and environmental error sources were considered for optimal modeling estimation. The approach is based to reference measurements in a close-range environment within a 10-meter distance to user-defined ground truth targets. Experiment results show that the errors in the distance are generally increased following the increase in range distance between the laser device and the targets. However, error variations between laser and reference measurements nearly constant relational to the range value. The index error of the Stonex X300 was computed based on mean measurements and found to be equal to 4.6717 mm. On the other hand, the horizontal angular measurements delivered from the TLS device were found to be more consistent with the reference measurements than with thee vertical angular measurements. However, the vertical angular measurements show more significant variations in particular measures compared to horizontal angular measurements. Following this, the angular error index was computed and found to be equal to 0.07 seconds and 0.13 seconds in horizontal and vertical angular measurements, respectively.

Scopus Crossref
View Publication
Publication Date
Mon Jan 15 2018
Journal Name
Iraqi Journal Of Laser
Effect of 410 nm Diode Laser Irradiation on the Growth of Burn Wounds-associated Bacteria, Pseudomonas Aeruginosa and Staphylococcus Aureus
...Show More Authors

The effect of 410nm with 100 mW output power and one centimetre spot size (0.128 W/cm2 power density) Diode laser irradiation at different exposure times on the growth of Gram-negative Pseudomonas aeruginosa and Gram-positive Staphylococcus aureus was evaluated. Seventy swap samples were collected from burn and infected wounds of 35 patients admitted to the burn-wound unit in Al-Yarmouk Teaching Hospital in Baghdad during the period from December 2014 to February 2015. These bacteria were isolated and identified depending on their growth on selective media, cultural characteristics, Gram stain morphology and biochemical tests and finally were confirmed by Vitek 2 compact system test .Susceptibility of bacterial isolates to 15antibiotics

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
An In Vitro Histological Study of Human Skin Wound Soldering Using 980 nm Diode Laser in Continuous versus Pulsed Modes.
...Show More Authors

Laser skin wound soldering offers many distinct advantages over conventional closure and laser welding techniques. Objective : to compare the histological effects of human skin wound soldering using 50 % human albumin solder and compound charcoal photosensitiser with 980 nm diode laser acting in various modes of action and parameters. Study Design/Materials and Methods: In this in vitro experimental study , Multiple 3-4 cm long full thickness incisions in a specimen of human skin were soldered using a 4 mm spot diameter beam of 980 nm diode laser(at different laser parameters and modes of action) with 50 % human albumin solder mixed with the compound charcoal at 5 % W/V concentration .After obtaining a successful wound soldering , the wo

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of waterlase laser and herbal alternative, green tea and Salvadora Persica (Siwak) extract on push-out bond strength
...Show More Authors

Background: The bond strength of root canal sealers to dentin was important for maintaining the integrity of the seal in root canal filling in both static and dynamic situations. In a static situation, it should eliminate any space that allowed the percolation of fluids between the filling and the wall while in a dynamic situation; it was needed to resist dislodgement of the filling during subsequent manipulation. Materials and Methods: Forty mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments. Instrumentation was done with copious irrigation of 5.25% sodium hypochlorite. Roots were randomly divided into four groups according to the type of cleaning and method of root canal irrig

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2015
Journal Name
Photomedicine And Laser Surgery
Evaluation of Temperature Elevation During Root Canal Treatment with Dual Wavelength Laser: 2780 nm Er,Cr:YSGG and 940 nm Diode
...Show More Authors

Scopus (36)
Scopus
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of Annealing on Optical and Electrical Properties of ZnS Thin Film Prepared by CO2 Laser Deposition Technique
...Show More Authors

In this work, ZnS thin films have been deposited by developed laser deposition technique on glass substrates at room temperature. After deposition process, the films were annealed at different temperatures (200ºC , 300 ºC and 400ºC ) using thermal furnace.The developed technique was used to obtain homogeneous thin films of ZnS depending on vaporization of this semiconductor material by continuous CO2 laser with a simple fan to ensure obtaining homogeneous films. ZnS thin films were annealed at temperature 200ºC, 300 ºC and 400ºC for (20) minute in vacuum environment. Optical properties of ZnS thin film such as absorbance, transmittance, reflectance, optical band gap, refractive index extinction coefficient and absorption coefficien

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Laser Irradiation Effect on The Optical Properties of CoO<sub>2</sub>Thin Films deposited via Semi-Computerized Spraying System
...Show More Authors
Abstract<p>In this paper deals with the effect laser irradiation on the optical properties of cobalt oxide (CoO<sub>2</sub>) thin films and that was prepared using semi computerized spray pyrolysis technique. The films deposited on glass substrate using such as an ideal value concentration of (0.02)M with a total volume of 100 ml. With substrate temperature was (350 C), spray rate (15 ml/min).The XRD diffraction given polycrystalline nature with Crystal system trigonal (hexagonal axes). The obtained films were irradiated by continuous green laser (532.8 nm) with power 140 mW for different time periods is 10 min,20min and 30min. The result was that the optical properties of cobalt oxide thin films affe</p> ... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Mar 01 2023
Journal Name
International Journal Bioautomation
Photobiomodulation Effect of 850 nm Near-infrared Diode Laser on the Release of M1-related Cytokines Inmonocytic THP-1 Cells
...Show More Authors

Photobiomodulation (PBM) is a form of the use of visible red and Near-infrared (NIR) light at low power, where a laser light photon is absorbed at the electronic level, without heat production. PBM can be applied in wide range of treatment to help the wound, inflammation, edema, and pain reduction. However, there is a lack of scientific documentation regarding its actual effects. Objectives: This study assesses the impact of PBM on the release of M1-related cytokine in monocyte cells with particular emphasis on interleukin-1β (IL-1β) and Tumour Necrosis Factor α (TNF-α). Methods: Tamm-Horsfall Protein 1 (THP-1) macrophages M1 cells have been exposed to the light from the diode laser of 850nmat different doses (0, 0.6, 1.2 and 3.

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Clinical And Experimental Dentistry
Eradication of mature biofilm from the isthmus region using Er, Cr: YSGG Laser as an activator of 2% chlorhexidine gluconate
...Show More Authors

View Publication
Scopus (3)
Crossref (5)
Scopus Crossref
Publication Date
Wed Dec 11 2019
Journal Name
Journal Of The College Of Education For Women
Taking Advantage of the Modulation Method on the Manicans in sitting the Basic Template Iraqi Female Bodies
...Show More Authors

The degree of the woman’s satisfaction on clothing depends, to a large extent, on the body measurements. If clothing is very wide, it shows her enormous and if it is too tight it may draw attention to the defects of the body. It may also lead to the compatibility or incompatibility of clothing with fashion. Whatever the quality of the garment in terms of sewing and design, the costume which is not suitable for body size may affect the physical style negatively and may give the wearer an improper look. Clothing was carried out without measurements and did not use models (templates). The method of preparation affected the overall appearance because it often did not fit the shape of the body completely. Therefore, people thought in many w

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2009
Journal Name
Ibn Al- Haitham J. Fo R Pure & Appl. Sci
Multiple Mixing Ratios of Gamma Rays Erγ)nEr(n, From 168 168 Reaction  Using a2 – Ratio Method
...Show More Authors

The -mixing of  - transition in Er 168 populated in Er)n,n(Er 168168  reaction is calculated in the present work by using a2- ratio method. This method has used in previou studies [4, 5, 6, 7] in case that the second transition is pure or for that transition which can be considered as pure only, but in one work we applied this method for two cases, in the first one for pure transition and in the 2nd one for non pure transitions. We take into accunt the experimental a2- coefficient for p revious works and -values for one transition only [1]. The results obtained are, in general, in agood agreement within associated errors, with those reported previously [1], the discrepancies that occur are due to inaccuracies existing

... Show More