Objectives: Small field of view gamma detection and imaging technologies for monitoring in vivo tracer uptake are rapidly expanding and being introduced for bed-side imaging and image guided surgical procedures. The Hybrid Gamma Camera (HGC) has been developed to enhance the localization of targeted radiopharmaceuticals during surgical procedures; for example in sentinel lymph node (SLN) biopsies and for bed-side imaging in procedures such as lacrimal drainage imaging and thyroid scanning. In this study, a prototype anthropomorphic head and neck phantom has been designed, constructed, and evaluated using representative modelled medical scenarios to study the capability of the HGC to detect SLNs and image small organs. Methods: An anthropomorphic head and neck phantom has been designed to mimic the adult head and neck including some internal organs and tissues of interest, such as the thyroid gland and sentinel lymph nodes. The design of the head and neck phantom included an adjustable inner jig holding the simulated SLNs and thyroid gland. The simulated thyroid gland was designed and 3D printed taking into consideration the size and the shape of a healthy adult thyroid gland. The inner sealed space of the thyroid was filled with 15MBq of 99mTc through two upper filling valves. Sealed micro-tubes (0.2ml) have been employed to simulate SLNs containing various 99mTc activity concentrations ranging between 0.1MBq and 1MBq, and can be positioned at any desired place in the head and neck region. An active background was simulated through mixing 10MBq of 99mTc solution with the water used to fill the outer shell of the head and neck phantom. Results: The head and neck phantom was employed to simulate a situation where there are four SLNs distributed at two different vertical levels and at two depths within the neck. Contrast to noise ratio (CNR) calculations were performed for the detected SLNs at an 80mm distance between both pinhole collimators (i.e. 0.5mm and 1.0mm diameters) and the surface of the head and neck phantom with a 100s acquisition time. The recorded CNR values for the simulated SLNs are higher when the HGC was fitted with the 1.0mm diameter pinhole collimator. For instance, the recorded CNR values for the superficially simulated SLN containing 0.1MBq of 99mTc using 0.5mm and 1.0mm diameter pinhole collimators are 6.48 and 16.42, respectively (~87% difference). The anatomical context provided by the hybrid imaging aided the localization process of radioactivity accumulation in simulated SLNs. Gamma and hybrid optical images were acquired using the HGC with both available pinhole collimators for the simulated thyroid gland. The thyroid images produced varied in terms of spatial resolution and detectability. The count profiles through the middle of the simulated thyroid gland images provided by both pinhole collimators were obtained. The HGC could clearly differentiate the individual peaks of both thyroid lobes in the gamma image produced by the 0.5mm pinhole collimator. In contrast, the recorded count profile for the acquired image using the 1.0mm diameter pinhole collimator showed broader peaks for both lobes, reflecting the degradation of the spatial resolution with increasing the diameter of the pinhole collimator. Conclusion: The capability of the HGC has been evaluated utilizing a prototype anthropomorphic head and neck phantom, and the gamma and hybrid images obtained demonstrate that it is ideally suited for intraoperative SLNs detection and small organ imaging. The standardization of test phantoms and protocols for SFOV portable gamma systems will provide an opportunity to collect data across various medical centers and research groups. Moreover, it will provide a technical baseline for researchers and clinical practitioners to consider when assessing their SFOV gamma imaging systems. The anthropomorphic head and neck phantom described is cost effective, reproducible, flexible and anatomically representative.
This research aims to removes dyes from waste water by adsorption using banana peels. The conduct experiment done by banana powder and banana gel to compare between them and find out which one is the most efficient in adsorption. Studying the effects different factors on adsorption material and calculate the best removal efficiency to get rid of the methylene blue dye (MB).
Vehicular Ad Hoc Networks (VANETs) are integral to Intelligent Transportation Systems (ITS), enabling real-time communication between vehicles and infrastructure to enhance traffic flow, road safety, and passenger experience. However, the open and dynamic nature of VANETs presents significant privacy and security challenges, including data eavesdropping, message manipulation, and unauthorized access. This study addresses these concerns by leveraging advancements in Fog Computing (FC), which offers lowlatency, distributed data processing near-end devices to enhance the resilience and security of VANET communications. The paper comprehensively analyzes the security frameworks for fog-enabled VANETs, introducing a novel taxonomy that c
... Show MoreIt is shown that pure and 3% boron doped a-Si0.1Ge0.9:H and a-Si0.1Ge0.9:N thin films
could be prepared by flash evaporation processes. The hydrogenation and nitrogenation
are very successful in situ after depositing the films. The FT-IR analysis gave all the
known absorbing bonds of hydrogen and nitrogen with Si and Ge.
Our data showed a considerable effect of annealing temperature on the structural and
optical properties of the prepared films. The optical energy gap (Eopt.) of a-Si0.1Ge0.9
samples showed to have significant increase with annealing temperature (Ta) also the
refractive index and the real part of dielectric constant increases with Ta, however the
extinction coefficient and imaginary part of dielect
Abstract
Asthma is a complex disease defined by chronic airway inflammation and airflow limitation causing variable respiratory symptoms which include shortness of breath (SOB), wheezing, chest tightness and cough. Asthma guidelines advocate adding a second long acting bronchodilator to medium doses of inhaled corticosteroids (ICS) rather using high doses of ICS alone to control moderate to severe persistent asthma. The aim of this study was to evaluate the clinical outcomes of three medication regimens indicated for Iraqi patients suffering from persistent asthma.
This study was interventional randomized clinical study conducted on a sample of adult Iraqi asthm
... Show MoreThe potential application of granules of brick waste (GBW) as a low-cost sorbent for removal of Ni+2ions from aqueous solutions has been studied. The properties of GBW were determined through several tests such as X-Ray diffraction (XRD), Energy dispersive X-ray (EDX), Scanning electron microscopy (SEM), and BET surface area. In batch tests, the influence of several operating parameters including contact time, initial concentration, agitation speed, and the dose of GBW was investigated. The best values of these parameters that provided maximum removal efficiency of nickel (39.4%) were 1.5 hr, 50 mg/L, 250 rpm, and 1.8 g/100mL, respectively. The adsorption data obtained by batch experiments subjected to the Three i
... Show MoreA new colorimetric-flow injection method has been developed and validated for the detection of Cefotaxime sodium in pharmaceutical formulations. This method stands out for its rapid and sensitive nature. The formation of a brown-colored complex between Cefotaxime sodium and the Biuret reagent in a highly alkaline environment serves as the basis for the detection. The intensity of this colored complex is measured using a custom-built Continuous Flow Injection Analyzer, enabling accurate quantification of Cefotaxime sodium. Optimization studies of the chemical and physical parameters such as dilution of Biuret reagent, effect of the medium basicity, flow rate, sample loop and others have been investigated. The calibration gra
... Show MoreAbstract Asthma is a complex disease defined by chronic airway inflammation and airflow limitation causing variable respiratory symptoms which include shortness of breath (SOB), wheezing, chest tightness and cough. Asthma guidelines advocate adding a second long acting bronchodilator to medium doses of inhaled corticosteroids (ICS) rather using high doses of ICS alone to control moderate to severe persistent asthma. The aim of this study was to evaluate the clinical outcomes of three medication regimens indicated for Iraqi patients suffering from persistent asthma. This study was interventional randomized clinical study conducted on a sample of adult Iraqi asthmatic patients in Baghdad City. The study com
... Show More