Preferred Language
Articles
/
vRYCBYcBVTCNdQwCWi2j
Fast Shot Boundary Detection Based on Separable Moments and Support Vector Machine
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Enhancement of gas response of annealed ZnO film for hydrogen gas detection
...Show More Authors

  The mechanism of hydrogen (H2) gas sensor in the range of 50-200 ppm of RF-sputtered annealed zinc oxide (ZnO) and without annealing was studied. The X-ray Diffraction( XRD) results showed that the Zn metal was completely converted to ZnO with a polycrystalline structure. The I–V characteristics of the device (PT/ZnO/Pt) measured at room temperature before and after annealing at 450 oC for4h, from which a linear relationship has been observed. The sensors had a maximum response to H2 at 350 oC for annealing ZnO and showed stable behavior for detecting H2 gases in the range of 50 to 200 ppm. The annealed film exhibited hig

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Use of cefoxitin as indicator for detection of Methicillin Resistant Staphylococcus aureus
...Show More Authors

Rapid and accurate identification of Methicillin Resistant Staphylococcus aureus is essential in limiting the spread of this bacterium. The aim of study is the detection of Methicillin Resistant Staphylococcus aureus (MRSA) and determining their susceptibility to some antimicrobial agent. A total of fifty clinical Staphylococcus aureus, isolated from the nose of health work staff in surgery unit of Kalar general hospital and from ear of patients attended to the same hospital. The susceptibilities of isolates were determined by the disc diffusion method with oxacillin (1 ?g) and cefoxitin (30 ?g), and by the mannitol salt agar supplemented with cefoxitin (MSA-CFOX), susceptibilities of isolates to other antimicrobial agent were determined b

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun May 11 2014
Journal Name
World Journal Of Experimental Biosciences
Detection of hydrolytic enzymes produced by Azospirillum brasiliense isolated from root soil
...Show More Authors

Publication Date
Sat Jan 02 2021
Journal Name
International Journal Of Pharmaceutical Research
Detection of Kaposi’s Associated Herpesvirus in Saliva of Drug Related Immunosupressed Patient
...Show More Authors

View Publication
Crossref
Publication Date
Sat Jan 13 2018
Journal Name
Journal Of Engineering
Producing Coordinate Time Series for Iraq's CORS Site for Detection Geophysical Phenomena
...Show More Authors

Global Navigation Satellite Systems (GNSS) have become an integral part of wide range of applications. One of these applications of GNSS is implementation of the cellular phone to locate the position of users and this technology has been employed in social media applications. Moreover, GNSS have been effectively employed in transportation, GIS, mobile satellite communications, and etc. On the other hand, the geomatics sciences use the GNSS for many practical and scientific applications such as surveying and mapping and monitoring, etc.

In this study, the GNSS raw data of ISER CORS, which is located in the North of Iraq, are processed and analyzed to build up coordinate time series for the purpose of detection the

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Detection of Autism Spectrum Disorder Using A 1-Dimensional Convolutional Neural Network
...Show More Authors

Autism Spectrum Disorder, also known as ASD, is a neurodevelopmental disease that impairs speech, social interaction, and behavior. Machine learning is a field of artificial intelligence that focuses on creating algorithms that can learn patterns and make ASD classification based on input data. The results of using machine learning algorithms to categorize ASD have been inconsistent. More research is needed to improve the accuracy of the classification of ASD. To address this, deep learning such as 1D CNN has been proposed as an alternative for the classification of ASD detection. The proposed techniques are evaluated on publicly available three different ASD datasets (children, Adults, and adolescents). Results strongly suggest that 1D

... Show More
View Publication Preview PDF
Scopus (32)
Crossref (22)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Tropical Journal Of Natural Product Research
Detection of Herpes Simplex Virus Type 1 in Patients Affected by Conjunctivitis
...Show More Authors

Herpes simplex virus (HSV) is a common human pathogen that causes severe infections in newborns and immunocompromised patients. Conjunctivitis or corneal epithelial keratitis is caused by HSV type 1 all over the world and at all times of the year. The present study was aimed at detecting HSV in patients suffering from conjunctivitis. One hundred and ten (110) clinical samples (90 patients and 20 controls, both males and females) of eye conjunctiva swabs were collected from patients of different ages. The samples were analyzed using qPCR and ELISA techniques. The qPCR results revealed that HSV was present in 47 (52.2%) of the 90 patients who were infected. Of these patients, 25 (48.0%) were males and 22 (57.8%) were females, indicati

... Show More
View Publication Preview PDF
Scopus
Publication Date
Mon Apr 19 2010
Journal Name
Computer And Information Science
Quantitative Detection of Left Ventricular Wall Motion Abnormality by Two-Dimensional Echocardiography
...Show More Authors

Echocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon May 09 2022
Journal Name
مجلة كلية التربية الاساسية الجامعة المستنصرية
Detection of sul1 resistance gene in Acinetobacter baumannii from different Clinical cases
...Show More Authors