Preferred Language
Articles
/
vBcd8pEBVTCNdQwC65zO
Scale-up of a fixed bed electrochemical reactor consisting of parallel screen electrode used for p-aminophenol production
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Oxidative Coupling Reaction for Micro Trace Analysis of Mebendazol Residual with p-bromoaniline in Presence of n- bromosuccinimide
...Show More Authors

Rapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1.  The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Oxidative Coupling Reaction for Micro Trace Analysis of Mebendazol Residual with p-bromoaniline in Presence of n- bromosuccinimide
...Show More Authors

Rapid, reproducible and accurate method has been developed for the assay for of mebendazol (MBZ) residual assay. The method is based on alkaline hydrolysis of MBZ with sodium hydroxide then oxidation with N-bromosuccinimide (NBS) followed by coupling with 4-Bromoaniline (4-BA) to yield a highly colored product absorbed at maximum 434 nm. Regression analysis of linearity range was found (0.6-2.8) µg.ml-1.  The optimum conditions that affect the oxidation were studied. The developed method was found to be precise with mean value of relative standard deviation (1.153- 1.303) and accurate with relative error (-0.5940-1.7821) .The calculated molar absorptivity and sandal sensitivity values of (29825 L.mol-1.cm-1), 0.0099 µg.cm-2 respe

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
CALCULATION BIASES FOR COEFFICIENTS AND SCALE PARAMETER FOR LINEAR (TYPE 1) EXTREME VALUE REGRESSION MODEL FOR LARGEST VALUES
...Show More Authors

Abstract

Characterized by the Ordinary Least Squares (OLS) on Maximum Likelihood for the greatest possible way that the exact moments are known , which means that it can be found, while the other method they are unknown, but approximations to their biases correct to 0(n-1) can be obtained by standard methods. In our research expressions for approximations to the biases of the ML estimators (the regression coefficients and scale parameter) for linear (type 1) Extreme Value Regression Model for Largest Values are presented by using the advanced approach depends on finding the first derivative, second and third.

View Publication Preview PDF
Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Energy Reports
Photoelectric properties of SnO2: Ag/P–Si heterojunction photodetector
...Show More Authors

N-type Tin dioxide thin films with thickness (350 nm) prepared by thermal evaporation method. The thin film SnO2 was doped with Ag by the rate (0.01, 0.02 and 0.03). Atomic Force Microscopic (AFM) was adopted to determine the grain size and roughness of the film surface. The electrical properties were determined by mean of Hall Measurement system and mobility was calculated. SnO2: Ag/P–Si photodetectors demonstration the highest described visible responsivity of (0.287 A/W) with the Ag ratio of (0.03). I–V characteristics with different power density were measured. The best sensitive value of the spectral response, specific detectivity and quantum efficiency at wavelength (422 nm).

View Publication
Scopus (41)
Crossref (41)
Scopus Clarivate Crossref
Publication Date
Wed Jul 05 2023
Journal Name
Thesis
P-Rational Submodules and Certain Types of Polyform Modules
...Show More Authors

The main objective of this thesis is to study new concepts (up to our knowledge) which are P-rational submodules, P-polyform and fully polyform modules. We studied a special type of rational submodule, called the P-rational submodule. A submodule N of an R-module M is called P-rational (Simply, N≤_prM), if N is pure and Hom_R (M/N,E(M))=0 where E(M) is the injective hull of M. Many properties of the P-rational submodules were investigated, and various characteristics were given and discussed that are analogous to the results which are known in the concept of the rational submodule. We used a P-rational submodule to define a P-polyform module which is contained properly in the polyform module. An R-module M is called P-polyform if every es

... Show More
Publication Date
Tue Nov 11 2025
Journal Name
Revista Iberoamericana De Psicología Del Ejercicio Y El Deporte, Issn 1886-8576, Vol. 18, Nº. 1, 2023, Págs. 19-29
Constructing A Measure of Psychological Disability and Its Relationship to Some Basic Skills and Fixed Playing Situations for Youth Football Players Under (19) Years Old
...Show More Authors

Autorías: Muwafaq Obayes Khudhair, Sanaa Rabeea Abed, Hayder Talib Jasim. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 1, 2023. Artículo de Revista en Dialnet.

View Publication Preview PDF
Publication Date
Sat Jun 01 2019
Journal Name
Acta Chromatographica
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi

... Show More
View Publication
Scopus (25)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Iosr-jdms
The Effect of Fixed Orthodontic Appliances on Gingival Health
...Show More Authors

Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Physics: Conference Series
Some Theorems of Fixed Point Approximations By Iteration Processes
...Show More Authors
Abstract<p>The purpose of this paper, is to study different iterations algorithms types three_steps called, new iteration, <italic>M</italic> <sup>∗</sup> −iteration, <italic>k</italic> −iteration, and Noor-iteration, for approximation of fixed points. We show that the new iteration process is faster than the existing leading iteration processes like <italic>M</italic> <sup>∗</sup> −iteration, <italic>k</italic> −iteration, and Noor-iteration process, for like contraction mappings. We support our analytic proof with a numerical example.</p>
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Al-kindy College Medical Journal
Safety profile of immediate post-partum intrauterine device insertion during caesarean delivery – a clinical trial with three years of follow up
...Show More Authors

Background Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq. Objectives To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women. Subjects and Methods A single arm clinical trial included 150 eligible women who attended Al-‎Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the ute

... Show More
Crossref