Highly Modified Asphalt (HiMA) binders have garnered significant attention due to their superior resistance to rutting, fatigue cracking, and thermal distress under heavy traffic loads and extreme environmental conditions. While elastomeric polymers such as Styrene- Butadiene-Styrene (SBS) have been extensively used in HiMA applications, the potential of plastomeric polymers, including Polyethylene (PE) and Ethylene Vinyl Acetate (EVA), remains largely unexplored. This study aims to evaluate the performance of reference binder (RB) modified with plastomeric HiMA asphalt in comparison to SBS-modified binders and determine the optimal polymer dosage for achieving an optimal balance between rutting resistance and fatigue durability. The experimental program involved modifying a base asphalt binder with SBS, PE, and EVA at dosages of 6%, 7%, and 8% by weight of binder. A comprehensive evaluation was conducted, including conventional tests (penetration, softening point, viscosity, mass loss, storage stability, and specific gravity) and rheological characterization using the Dynamic Shear Rheometer (DSR). The Multiple Stress Creep Recovery (MSCR) test was employed to assess high-temperature performance, while the Linear Amplitude Sweep (LAS) test evaluated fatigue behavior. Additionally, an Overall Desirability (OD) analysis was performed to integrate multiple performance criteria and establish a ranking for each modification. The results demonstrated that SBS-modified binders exhibited the most balanced performance, with SBS8 achieving the highest elastic recovery (52.87%) and superior fatigue life, exceeding 1,017,904 cycles at 2.5% strain. PE8 exhibited exceptional rutting resistance, reaching the lowest Jnr 3.2 value (0.0078 kPa−1); however, its limited elasticity (15.7% recovery) indicated reduced flexibility. EVA modifications demonstrated marginal improvements in fatigue resistance but failed to meet the AASHTO M332 criteria for high-traffic applications. The OD analysis ranked SBS8 as the most effective HiMA binder (OD score = 0.715), followed by SBS7 (0.588) and SBS6 (0.509). PE7 (0.354) and PE6 (0.337) demonstrated moderate performance, whereas EVA had the lowest desirability score (0.000). Based on these findings, SBS-modified binders are recommended for applications requiring a balance between fatigue and rutting resistance, whereas PE-based HiMA is more suitable for high-temperature regions where rutting is the primary concern. Further field studies are necessary to validate the long-term durability of plastomeric HiMA binders and optimize their use for specific pavement conditions.
The polymers modified Poly(vinyl chloride) differ in their tendency to photo oxidation comparing with that unmodified. It has been studied Photostability for modified Poly(vinyl chloride) chains using Schiff’s bases derivative of (5-amino-1, 3, 4-thiadiazole-2-thiol) in a manner casting of plastic chips with thickness (40) in a solvent Tetrahydrofuran. It has been determined the effectiveness Photostability of these modified polymers through the photo degradation rate constant for photostabilizer (kd) for the modified Poly (vinyl chloride). Attributed efficiency of these Poly(vinyl chloride) chips in Photostability by replace the atom Cl Poly(vinyl chloride) chains ends more stable than light stabilizer.
Metoprolol is a β1 adrenergic blocker used in treatment of heart diseases. Metoprolol (100mg) tablets was formulated as a modified release oral system utilizing the concept of bilayer system, first layer contained (30mg) as immediate release and the other (70mg) in the sustained release matrix. The immediate release layer consisted of lactose or microcrystalline cellulose as diluents with sodium starch glycolate or sodium croscarmellose as disintegrants. The result showed that the layer contains microcrystalline cellulose and 2% sodium starch glycolate gave disintegration time similar to that of conventional metoprolol tartrate tablet. This result was subjected in the subsequent preparation of the bilayer tablet. The
... Show MoreThe present study aimed to examine the concordance between FISH/CISH techniques for assessment of amplification of her2neu gene in Iraqi breast carcinoma patients. Seventy four (74) Iraqi breast cancer patients were involved at the study from the Histopathology Department at the Central Public Health Laboratory in Bagdad, Iraq. Amplification of HER2neu was detected in (33.8%) by fluorescence in situ hybridization and (13.51%) showed high amplification by chromogenic in situ hybridization and (32.43%) showed low amplification. The results of chromogenic in situ hybridization were significantly correlated with the results of two-color fluorescence in situ hybridization with the same tumors. In addition, the study involved the correlation betw
... Show MoreIndustrial dyes are major pollutants in wastewater and river water with an initial visible concentration of 1 mg/L. Recent studies have shown the possibility of using polyphenol oxidase in catalytic biological treatment due to its ability to oxidize a large number of dyes and pollutants in wastewater and the flexibility to work in wide ranges of temperature, pH and salinity. It is easy availability as well as the low economic cost resulting from its use in biological treatments, this enzyme polyphenol oxidase was used. The findings in this study showed that the extraction of polyphenol oxidase (PPO) from potato peel was homogenized with potassium phosphate buffer (0.1 M, pH 7) at a ratio of 1:10 (weight: volume) for two min. The res
... Show MoreZinc, Copper, Selenium, Magnesium, Manganese, Chromium, Iron, Nickel, Cobalt, Vanadium and Germanium were determined by atomic absorption spectrophotometer (AAS) in blood serum of patients with rheumatoid arthritis, (30) patients (14male and 16female) with age range (37-60) years compared with normal tensive control. The analysis of results showed that the mean value of concentration (Magnesium, Manganese and Nickel) were significantly higher in patients with rheumatoid arthritis compared to that of healthy, while the mean levels of serum (Zinc, Copper, Selenium, Chromium, Iron, Cobalt and Germanium) were significantly lower than controls. There were no significant changes in overall mean concentration of serum Vanadium in patients
... Show MoreThis research investigated the importance and priorities of the project overhead costs in Iraq via a questionnaire using the fuzzy analytic hierarchy process technique (FAHP). Using this technique is very important in the uncertain circumstances as in our country. The researcher reached to frame an equation through the results of the priorities of weights include the percentages of each of the main items of the project overhead costs. The researcher tested this equation by applying it to one of the completed projects and the results showed suitability for the application. The percentages of the (salaries, grants, and incentives) and (fieldwork requirements) in equation represent approximately two-thirds of project overhe
... Show MoreFast dissolving film can be defined as a dosage form, which when placed in the oral cavity. It will rapidly disintegrate and dissolves to release the medication for oral mucosal absorption or allow for the gastrointestinal absorption to be achieved when swallowed.
Flurbiprofen is non-steroidal anti-inflammatory agent with antipyretic and analgesic properties and can be used in low doses 8.75 mg as analgesic and anti inflammatory agent in sore throat infection. This study aims to formulate flurbiprofen as oral dissolving films, to improve the effective relief of pain with severe sore throats with little or no adverse effect.
Nine formulas were prepared using solvent-casting method, and t
... Show MoreIn this work, we have examined the spectral response of (p-CuAlSe2/n-Si) detector, (CAS) thin films deposited by thermal evaporation at RT with a thickness (450) nm, and annealing temperature at (473K) for 2 h. Optical transmission measurements displayed reasonably slight transmission besides higher absorbance trendy the visible region, energy gaps were observed by annealing, were found to be direct, and decreased with the effect of annealing. The extreme responsivity value arises at wavelength 459 nm, with improvement value of specific detectivity and quantum efficiency the annealing films be situated originate as greatest suitable aimed at numerous device application.
This research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.
Abstract
Research aims : The aim of the research is to evaluate the reality of the inspection teams' work in the health institutions belonging to Dhi-Qar health office .
Purpose: This research seeks to present a point of view based on knowing the extent of health service quality in Dhi-Qar governorate and discover the role of the inspection teams in enhancing the health service.
Design / Methodology/ Approach: The experimental method has been used and the questionnaire has also been used to collect data in order to develop a reliable and correct measurement model for the research's variables . The research's hypotheses have been tested through using some statistical treat
... Show More