Highly Modified Asphalt (HiMA) binders have garnered significant attention due to their superior resistance to rutting, fatigue cracking, and thermal distress under heavy traffic loads and extreme environmental conditions. While elastomeric polymers such as Styrene- Butadiene-Styrene (SBS) have been extensively used in HiMA applications, the potential of plastomeric polymers, including Polyethylene (PE) and Ethylene Vinyl Acetate (EVA), remains largely unexplored. This study aims to evaluate the performance of reference binder (RB) modified with plastomeric HiMA asphalt in comparison to SBS-modified binders and determine the optimal polymer dosage for achieving an optimal balance between rutting resistance and fatigue durability. The experimental program involved modifying a base asphalt binder with SBS, PE, and EVA at dosages of 6%, 7%, and 8% by weight of binder. A comprehensive evaluation was conducted, including conventional tests (penetration, softening point, viscosity, mass loss, storage stability, and specific gravity) and rheological characterization using the Dynamic Shear Rheometer (DSR). The Multiple Stress Creep Recovery (MSCR) test was employed to assess high-temperature performance, while the Linear Amplitude Sweep (LAS) test evaluated fatigue behavior. Additionally, an Overall Desirability (OD) analysis was performed to integrate multiple performance criteria and establish a ranking for each modification. The results demonstrated that SBS-modified binders exhibited the most balanced performance, with SBS8 achieving the highest elastic recovery (52.87%) and superior fatigue life, exceeding 1,017,904 cycles at 2.5% strain. PE8 exhibited exceptional rutting resistance, reaching the lowest Jnr 3.2 value (0.0078 kPa−1); however, its limited elasticity (15.7% recovery) indicated reduced flexibility. EVA modifications demonstrated marginal improvements in fatigue resistance but failed to meet the AASHTO M332 criteria for high-traffic applications. The OD analysis ranked SBS8 as the most effective HiMA binder (OD score = 0.715), followed by SBS7 (0.588) and SBS6 (0.509). PE7 (0.354) and PE6 (0.337) demonstrated moderate performance, whereas EVA had the lowest desirability score (0.000). Based on these findings, SBS-modified binders are recommended for applications requiring a balance between fatigue and rutting resistance, whereas PE-based HiMA is more suitable for high-temperature regions where rutting is the primary concern. Further field studies are necessary to validate the long-term durability of plastomeric HiMA binders and optimize their use for specific pavement conditions.
The present study employed the NAG-4SX3-3D analyzer to precisely measure the energy response of the sensor. The goal was to enhance the understanding of this technology by providing expert information about the device. This technology offers an economical, quick, accurate, and sensitive approach. By utilizing the turbidity method, Cyproheptadine hydrochloride (CPH) was quantified in pharmaceutical samples without the need for additional substances. CPH is expected to undergo a direct reaction with calcium hexacyanoferrate, resulting in the formation of white precipitates. The linear range for CPH measurement falls within the range of (0.008–30) mM. The relative standard deviation (RSD) for six repetitions at concentrations of (6 and
... Show MoreThe current study aimed to determine the morphometric and meristic characteristics of the North African catfish Clarias gariepinus (Burchell, 1822). Six specimens of C. gariepinus were collected from the Tigris River, in central Iraq. This study is considered the confirmation first record of this species in Iraq, and the second documentation of this exotic fish. The present species is characterized by a very long dorsal fin, a rounded caudal fin and four pairs of barbels.
Antibiotics present the greatest threat to soil and aquatic ecosystems among the different therapeutic groups of medicines (which include prescription drugs and treatments for cancer). The strongest drugs, antibiotics, have been utilized to stop the growth of microorganisms or eradicate them. Using high-performance liquid chromatography technology with fluorescence detection, the amounts of levofloxacin and tetracycline in the wastewater from three hospitals (Medical City, Al-Kindi, and Al-Yarmouk) were determined. Levofloxacin and tetracycline were chosen in this study because they are the most important water pollutants. These antibiotic residues were separated and measured using a gradient elution technique on a reverse-phase C18
... Show MoreVillages in most rural areas of the developing world, including Iraq, suffer from a deterioration in the urban structure in its various aspects, both in the lack of internal planning in terms of residential unit design which is not commensurate with the sustainable health life, in addition to the lack of infrastructure and community services networks As well as road networks linking them to neighboring urban centers, which was accompanied by the emergence of other problems, including the desire of the population to migrate to neighboring cities and the deterioration of economic activities due to lack of activation of economic development plans (Rural villages suffer from a lack of interest in urban development within the regional spatial
... Show MorePhase change materials are extensively studied for use in low-, mid-, and high-temperature applications due to their melting and solidification temperatures, latent heat, and thermophysical properties. This work aims to explore the energy stored, or released and their duration for the energy storage unit formed of a phase change material surrounding a tube within which a hot or cold, single or Two-Phase fluid flows, serving as a heat source or sink. The 3D axial transient thermal analysis of the energy storage unit is performed using the finite element method via a MATLAB-developed computer program. The effects of single- or Two-Phase fluid flow on temperature distribution, solidification, melting duration, and energy stored within phase ch
... Show MoreA true random TTL pulse generator was implemented and investigated for quantum key distribution systems. The random TTL signals are generated by low cost components available in the local markets. The TTL signals are obtained by using true random binary sequences based on registering photon arrival time difference registered in coincidence windows between two single – photon detectors. The true random TTL pulse generator performance was tested by using time to digital converters which gives accurate readings for photon arrival time. The proposed true random pulse TTL generator can be used in any quantum -key distribution system for random operation of the transmitters for these systems