Vancomycin Staphylococcus aureus (VRSA) is a strain of S. aureus that is considered the main cause of bacterial skin and soft tissue infections. It has acquired resistance to vancomycin and represents a therapeutic challenge. The current study aimed to compare the possible therapeutic effects of VRSA bacteriocin (VRSAcin) on the treatment of skin infection in mice with those of an antibiotic (linezolid). The results showed that of the fifty swabs obtained from human skin wounds. One isolate was selected for VRSAcin extraction depending on its antibiotic resistance using an antibiotic susceptibility test.An agar well diffusion test was used to determine bacteriocin’s antibacterial activity, as well as its a minimum inhibitory concentration, minimum bactericidal concentration, and antibiofilm efficiency against gram-positive and gram-negative bacteria that were resistant to many medicines. The freshly developed antibacterial substance VRSAcin shows promise. Bacteriocin from VRSA was extracted and studied the optimal conditions for the Production following Purification of bacteriocin by ammonium sulfate precipitation followed by cation-exchange chromatography. The molecular weight of bacteriocin about (29 kDa) were determined by Sodium Dodecyl Sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). The typical conditions for the production of VRSAcin include a pH of 7 and a temperature of 37 ◦C for 48 h. In mice, VRSA-contaminated wounds revealed severe tissue distraction and inflammation that extended to the hypodermis, while VRSA-treated skin showed mild changes and localized lesions to the epidermis and upper dermis. The skin of linezolid ointment-treated mice showed moderate to severe changes. In conclusion, VRSA strain infections in human burned skin were more common than expected. In vivo studies in mice indicated that wounded skin infected with VRSA can be treated with VRSAcin as an antibacterial agent that promotes healing processes with obvious superiority to linezolid ointment. As a result, the VRSA develops bacteriocins that are appropriate for regulating AMR, Gram-positive and Gram-negative bacteria, and may be useful in wound dressings.
The complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show MoreIn this study, the flexural performance of a new composite beam–slab system filled with concrete material was investigated, where this system was mainly prepared from lightweight cold-formed steel sections of a beam and a deck slab for carrying heavy floor loads as another concept of a conventional composite system with a lower cost impact. For this purpose, seven samples of a profile steel sheet–dry board deck slab (PSSDB/PDS) carried by a steel cold-formed C-purlins beam (CB) were prepared and named “composite CBPDS specimen”, which were tested under a static bending load. Specifically, the effects of the profile steel sheet (PSS) direction (parallel or perpendicular to the span of the specimen) using different C-purlins c
... Show MoreAs a result of rapid industrialization and population development, toxic chemicals have been introduced into water systems in recent decades. Because of its excellent efficiency and simple design, the three-dimensional (3D) electro-Fenton method has been used for the treatment of wastewater. The goal of the current study is to explore the efficiency of phenol removal by the 3D electro-Fenton process, which is one of the advanced oxidation processes (AOPs). In the present work, the effect of the addition of granular activated carbon (GAC) particles to the electro-Fenton system as the third electrode would be investigated in the presence of graphite as the anode and nickel foam as the cathode, which is the source of electro-generated hydrogen
... Show MoreCircular thin walled structures have wide range of applications. This type of structure is generally exposed to different types of loads, but one of the most important types is a buckling. In this work, the phenomena of buckling was studied by using finite element analysis. The circular thin walled structure in this study is constructed from; cylindrical thin shell strengthen by longitudinal stringers, subjected to pure bending in one plane. In addition, Taguchi method was used to identify the optimum combination set of parameters for enhancement of the critical buckling load value, as well as to investigate the most effective parameter. The parameters that have been analyzed were; cylinder shell thickness, shape of stiffeners section an
... Show Moreتضمن هذا العمل تحضير ليكند قاعدة شيف جديدة مشتقة من مادة البولي أكريلاميد والكلوترالديهايد [(2S, 2'S) – N, N' - (pentane-1, 5-diylidene) bis (2- methylbutan amide)] مع بعض المعادن الثقيلة (Cr + 3 Mn + 3 , Fe + 3 , ,Co + 2, Ni + 2 ,Cu + 2 Zn + 2 , Cd + 2,) لتنتج المعقدات المقابلة. تم تشخيص قواعد شيف ومعقداتها المعدنية بأستخدام طيف الأشعة تحت الحمراء والأشعة المرئية وفوق البنفسجية، والتوصيلية ,وقيم المغناطيسية والتحليل الحراري الوزني وحيود الأشعة السينية ومجه
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show More