Preferred Language
Articles
/
uBd7MI8BVTCNdQwCl19h
Cleaning efficacy and instrumentation time using rotary file system in primary molars (comparative study)
...Show More Authors

ABSTRACT— In primary teeth, root canal treatment is a time consuming and challenging procedure, particularly during the most important step in endodontic treatment which is the preparation of the canal. Pulpectomy is the treatment of choice in all the necrotic primary teeth. For better treatment protocol, advancing technology brought the rotary system to reduce the manual dexterity and improve the quality of treatment for pulpectomy. This study aimed to compare and assess the efficacy of cleaning and the time required for the instrumentation during the preparation of root canals of the primary molars using the rotary and the manual (conventional) systems. Thirty root canals of primary teeth were selected. These teeth submitted to access opening and then all the canals injected with Indian ink. Then, 48 hours later, the teeth were randomly classified into two groups: group A (n=fifteen tooth): where the manual preparation of the root canals was done by stainless steel K- files, while group B (n= fifteen tooth): consisted of the root canals that prepared with rotary two shape system. The total instrumentation time was measured using a digital stopwatch. After that, a disk bur was used to section the roots. Then, a digital camera was used to photograph the specimens to evaluate the root canal cleaning. The cleaning efficacy was compared at the coronal, middle and apical level. In the coronal third, rotary two shape system showed more removal to the ink than the K-file with statistical significant difference (p <0.05), however, for the middle third of the canal, no statistical difference was found between the two systems (p=0.05). While at the apical level, K-file showed more removal to the ink than the rotary two shape system and with statistical significant difference (p <0.05). Evaluation of the total samples revealed no statistical significant difference concerning the efficacy of cleaning between K-files and rotary two shape system files. The group that was rotary prepared took less time for the canal preparation as compared to the manual group (80.063 sec., 144.576 sec. respectively). No significant difference was found between the two systems concerning the cleaning efficacy. Instrumentation done by the rotary system took significantly less time than that of the manual. KEYWORDS: Cleaning efficacy, manual instrumentation, primary teeth, rotary instrumentation.

Publication Date
Mon Jan 01 2024
Journal Name
Brazilian Dental Science
Antimicrobial activity of Er,Cr:YSGG and Ultrasonic on E. faecalis biofilm in the mesial root canal systems of lower molars
...Show More Authors

Scopus (2)
Scopus
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Angular Laser Cleaning of Aluminum Al-4004 with Different Spot Sizes
...Show More Authors

Abstract: When it comes to applications in welding, cutting, and surface engineering, the utilization of high-power fiber-delivered beams from solid-state lasers offers several benefits. This paper addresses the issue of cleaning the surface of the samples with different spot sizes (50, 100 and 200) (industrial ytterbium fiber laser) to prepared it to be welded. Angular laser cleaning with incident angles (5, 10, 15, 20, 25, 30) ° with different powers (3, 5, 7, 10) W and hatch distance 0.001 was use for implemented.

View Publication Preview PDF
Publication Date
Fri Dec 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Comparison of Estimation Sonic Shear Wave Time Using Empirical Correlations and Artificial Neural Network
...Show More Authors

Wellbore instability and sand production onset modeling are very affected by Sonic Shear Wave Time (SSW). In any field, SSW is not available for all wells due to the high cost of measuring. Many authors developed empirical correlations using information from selected worldwide fields for SSW prediction. Recently, researchers have used different Artificial Intelligence methods for estimating SSW. Three existing empirical correlations of Carroll, Freund, and Brocher are used to estimate SSW in this paper, while a fourth new empirical correlation is established. For comparing with the empirical correlation results, another study's Artificial Neural Network (ANN) was used. The same data t

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Mar 29 2018
Journal Name
Construction Research Congress 2018
Validation of Time-Safety Influence Curve Using Empirical Safety and Injury Data—Poisson Regression
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
The Role of Metformin in patients with Primary Hypothyroidism
...Show More Authors

Background: Insulin resistance is present in 50% or more of patients with primary hypothyroidism. Metformin can decrease TSH levels in these patients by a complex matter, this can be of great help in clinical practice.

Objective: This study was designed to evaluate the effect of metformin in reducing TSH levels in patients with primary hypothyroidism.

Methods: Hundred patients with primary hypothyroidism, 82 females, 18 males were included in this study, everyone was followed up for two months after adding metformin 850 mg twice daily in addition to thyroxin.

Results: 36 patients (36%) have a normal baseline TSH and no change after 2 months, 64 pa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 04 2022
Journal Name
Journal Of Research In Medical And Dental Science
Efficacy of Several Forms of Storage Medium on Avulsed Teeth's Enamel Surface Roughness (An in Vitro Study)
...Show More Authors

Efficacy of Several Forms of Storage Medium on Avulsed Teeth's Enamel Surface Roughness (An in Vitro Study), Rawaa Sadiq Obeid1*, Muna Saleem Khalaf2

View Publication Preview PDF
Publication Date
Wed Oct 16 2019
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Antibacterial Efficacy of Silver Nanoparticles as an Irrigant against Enterococcus faecalis In vitro Study
...Show More Authors

Background: Successful root canal therapy depends on thorough chemo mechanical debridement of pulpal tissue, dentin debris and infective microorganisms. Objective: This study aimed to investigate the antibacterial effect of silver nanoparticles, sodium hypochlorite and chlorhexidine in reducing the bacterial infection of the root canals. Materials and Methods: The root canals of 55 single-rooted teeth were cleaned, shaped, and sterilized. All the teeth samples were inoculated with Enterococcus faecalis and incubated at 37°C for 2 weeks. Then, the teeth were divided into four groups. Group I (n=15): 100 ppm silver nanoparticles, Group II (n=15): 2.5 sodium hypochlorite, Group III (n=15): 2% chlorhexidine, IV (n=10): Normal saline as a contr

... Show More
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Assessment of Inflammasome Activity in Type 2 Diabetes Mellitus and Simple Obesity: Comparative Study
...Show More Authors

Inflammasome is a multiprotein oligomer complex which is the precursor procaspase-1 and is a component of the innate immune system so that this study aimed to determine the serum levels of interleukin-1? and 18 in patients with T2D and simple obesity in an attempt to clarify the role of inflammasome in these disorders.Twenty five known cases of T2D, twenty four patients with simple obesity and twenty healthy subjects were randomly recruited from AL-Kindy Teaching Hospital in Baghdad to enroll in this study. All the data about the demographic characteristics and anthropometric measurements were determined in all patients, also the C-reactive protein and serum interleukin (IL)-1? and IL-18 levels were obtained from each patient. The results s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
A Comparative Study between Transcutaneous Bilirubinometry and Total Serum Bilirubin Measurement in Jaundiced Newborns
...Show More Authors

Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. 

Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice.

Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 30 2015
Journal Name
College Of Islamic Sciences
The other day in the Holy Quran and the four Gospels: A comparative study
...Show More Authors

The other day in the Holy Quran and the four Gospels

View Publication Preview PDF