The present study was conducted to evaluate the effect of fungi Gigaspora margarita and Glomus desriticola in stimulating the resistance of the capsicum annuum L. towards the chromium and lead after 60 days, planting and using the pots in the glass house. The highest concentration of chromium and lead in the root was found in the presence of the mycorrhizal mixture (194.93, 150.40) μg / g, respectively, compared to the lowest concentration (90.69, 79.37) μg / g respectively, while the highest concentration of chromium and lead in the shoot was found in the presence of the mycorrhizal mixture (94.63, 79.33) μg / g respectively, compared with the lowest concentration in the control treatment (72.58, 60.70) μg / g respectively. The results showed the highest uptake efficiency and low translocation and phytoextraction efficiency of chromium and lead (179.73, 0.49 and 19.56) μg / g respectively for chromium and (144.63, 0.53 and 15.29) μg / g respectively for lead. The highest percentage of mycorrhizal mixture was recorded in the Intensity of the Mycorrhizal Colonization in the root System and root Fragments reached to (23.61, 26.50) % respectively, while the lowest percentage in mixing (chromium+lead) was (13.22, 13.47) % respectively. The highest percentage of mycorrhizal dependency was found in the mycorrhizal mixture with mixing (chromium+lead) which was 193.16% compared with the least of mycorrhizal dependency in Gigaspora margarita reached 98.34%. The lowest magnesium content in the control treatment was 28.36 mg / dry weight while the mycorrhizal mixture recorded the highest content of 33.41 mg / dry weight. The highest activity of guaiacol peroxidase and glutathione reductas in the treatment of the mycorrhizal mixture and mixing to heavy metals was (50.93, 10.11) absorption unit / gw fresh roots respectively compared with the lowest activity of the enzyme in the control was (31.48, 3.55) absorption unit / gw fresh roots respectively, all the tables showed significant differences.
<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreAlbizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show MoreThis study was designed to compare the effect of two types of viral hepatitis A and E (HAV
and HEV) on liver functions in Iraqi individuals by the measurement of biochemical changes
associated with hepatitis.
The study performed on 58 HEV and 66 HAV infected patients compared with 28 healthy
subjects. The measured biochemical tests include total serum bilirubin, serum transminases (ALT
and AST) alkaline phosphatase (ALP) and gamma glutamyl transferase (GGT).
The study showed that adolescent and young adults (17-29) years, were mostly affected by
HEV while children (5-12) years were frequently affected by HAV. The severity of liver damage in
HEV patients was higher than HAV patients as a result of high serum transa
This research is carried out to investigate the behavior of self-compacting concrete (SCC) two-way slabs with central square opening under uniformly distributed loads. The experimental part of this research is based on casting and testing six SCC simply supported square slabs having the same dimentions and reinforcement. One of these slabs was cast without opening as a control slab. While, the other five slabs having opening ratios (OR) of 2.78%, 6.25%, 11.11%, 17.36% and 25.00%. From the experimental results it is found that the maximum percentage decrease in cracking and ultimate uniform loads were 31.82% and 12.17% compared to control slab for opening ratios (OR
... Show MoreSolid‐waste management, particularly of aluminum (Al), is a challenge that is being confronted around the world. Therefore, it is valuable to explore methods that can minimize the exploitation of natural assets, such as recycling. In this study, using hazardous Al waste as the main electrodes in the electrocoagulation (EC) process for dye removal from wastewater was discussed. The EC process is considered to be one of the most efficient, promising, and cost‐effective ways of handling various toxic effluents. The effect of current density (10, 20, and 30 mA/cm2), electrolyte concentration (1 and 2 g/L), and initial concentration of Brilliant Blue dye (15 and 30 mg/L) on