Image compression is one of the data compression types applied to digital images in order to reduce their high cost for storage and/or transmission. Image compression algorithms may take the benefit of visual sensitivity and statistical properties of image data to deliver superior results in comparison with generic data compression schemes, which are used for other digital data. In the first approach, the input image is divided into blocks, each of which is 16 x 16, 32 x 32, or 64 x 64 pixels. The blocks are converted first into a string; then, encoded by using a lossless and dictionary-based algorithm known as arithmetic coding. The more occurrence of the pixels values is codded in few bits compare with pixel values of less occurrence through the sub intervals between the range 0 and 1. Finally, the stream of compressed tables is reassembled for decompressing (image restoration). The results showed a compression gain of 10-12% and less time consumption when applying this type of coding to each block rather than the entire image. To improve the compression ratio, the second approach was used based on the YCbCr colour model. In this regard, images were decomposed into four sub-bands (low-low, high-low, low-high, and high-high) by using the discrete wavelet transform compression algorithm. Then, the low-low sub-band was transmuted to frequency components (low and high) via discrete wavelet transform. Next, these components were quantized by using scalar quantization and then scanning in a zigzag way. The compression ratio result is 15.1 to 27.5 for magnetic resonance imaging with a different peak signal to noise ratio and mean square error; 25 to 43 for X-ray images; 32 to 46 for computed tomography scan images; and 19 to 36 for magnetic resonance imaging brain images. The second approach showed an improved compression scheme compared to the first approach considering compression ratio, peak signal to noise ratio, and mean square error.
Objectives: The study aims: (1) To determine effectiveness of instructional health education vascular access on hemodialysis patients' knowledge, (2) To find out the association between effects of instructional health education vascular access and demographic characteristics of (age, gender and educational level). Methodology: A quasi experimental study –control study design is carried out at AL-Hussein Teaching Hospital in AL-Nasiriyah City, from 3November,2015 to 2 June, 2016. A non-probability (Purposive sample) of (80) patients with vascular access devices on maintenance hemodialysis patients divided int
Background: It is well-known that silicon oil (SO) injection into the vitreous cavity after pars plana vitrectomy is usually associated with high intraocular pressure.
Objectives: To determine the influence of silicon oil (SO) removal on IOP level after pars plana vitrectomy for spontaneous rhegmatogenous retinal detachment (RRD)
Subjects and Methods: A prospective study was conducted at Ibn Al-Haitham eye teaching hospital, Baghdad- Iraq. Intraocular pressure (IOP) was measured pre and post SO removal in patients who have underwent retinal detachment surgery with SO injection of 1000 centistokes (cSt) viscosity. Baseline IOP was measured for all the patient before the SO
... Show MoreObjectives: to evaluate patient knowledge with hemodialysis and to determine the effectiveness of Self-regulation Fluid Program on Patients with hemodialysis self-efficacy for fluid adherence in Al-Diwaniyah Teaching Hospital.
Methodology: A quasi-experimental design (two group design: pre-test and post-test) was used. This study was conducted in Al-Diwaniya Teaching Hospital for the period from (15th of October 2018 to 20th of May 2019) on a non-probability (purposive) sample consisting of (60 patients) treatment in hemodialysis units. A questionnaire was built as a data collection tool and consisted of four parts:
First part: Demographic characteristics of the pati
... Show MoreAbstract
Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through eviden
... Show MoreThis study deals with air pollution tolerance index (APTI) and anatomical variation in leaves of two species of terrestrial plants Ficus sp. and Conocarpus sp. that have bee commonly the separated along roadsides in many stations within Babylon province. APTI values of both species were less than 10 during study period which represented sensitivity of these plants to air pollution. There are Anatomical responses to pollution in the leaves of both studied species. Main adaptations included increased thickness of parenchyma cell walls with clear dark deposits in sections of Ficus sp. from sections of stations 2 and 4 which represent polluted stations. Conocarpus sp. main adaptation included stomata increased in density and decreased in size w
... Show MoreBackground: Fruits and their by-products are the primary sources of bioactive chemicals in plants. Because of its phytochemical richness, Annona squamosa fruits have gained the alertness of people willing in health-promoting diets. The purpose of this in vitro study was to evaluate the cytocompatibility effect of ethanolic crude extract of Annona squamosa pulp against a human normal cell line as a mouthwash for children. Material and method: The ethanolic extract of Annona squamosa pulp was extracted using the ultrasonic method and then lyophilized to make it powder. The MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide) test was performed to investigate the cytotoxic activity of the pulp extract on a human normal cell l
... Show MoreDuring this article, we have a tendency to show the peristaltic activity of magnetohydrodynamics flow of carreau fluid with heat transfer influence in an inclined tapered asymmetric channel through porous medium by exploitation the influence of non-slip boundary conditions. The tapered asymmetric channel is often created because of the intrauterine fluid flow induced by myometrial contraction and it had been simulated by asymmetric peristaltic fluid flow in an exceedingly two dimensional infinite non uniform channel, this fluid is known as hereby carreau fluid, conjointly we are able to say that one amongst carreau's applications is that the blood flow within the body of human. Industrial field, silicon oil is an example of carreau
... Show MoreThe study objective was to conduct Pharmacoeconomics study (cost-effective analysis) between infliximab reference (Remicade) and its biosimilar (Remsima) in patients with rheumatoid arthritis (RA) in Iraqi hospitals.
This is a retrospective multicenter pharmacoeconomic analysis conducted at two large teaching governmental hospitals in Baghdad, Iraq which provided infliximab to patients with RA. Data were collected from patient’s medical records and face-to-face interviews with the patients from December 2021 to April 2022.
The study included 57 patients with rheumatoid arthritis (RA). The patients were categorized into two groups according to the type of infliximab they received over 30 weeks: 27 patients received
... Show MoreThis study presents a rapid, sensitive, and straightforward approach to measure chlorpheniramine maleate (CPM) by using turbidity CFIA. The method involves CPM reacting with sodium nitroprusside (Nitropress) to produce a pale white precipitate. The NAG-SSP-5S1D analyzer was used to measure turbidity at 0°–180° angle to detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles. The linear range of CPM measurements was between 0.008 and 11 m.mol/L, with correlation coefficient of 0.9983 and R2% = 99.65. The limit of detection was determined to be 0.0328 µg/sample from the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was less than 0.4% (n = 6
... Show More