Preferred Language
Articles
/
thcsY5ABVTCNdQwC3IiU
Prevalence of Pathogenic Bacteria from Contaminated Yemeni Currency Notes in Taiz City
...Show More Authors

ABSTRACT: Pathogenic bacteria responsible for the causation of many common diseases have been identified on currency notes. The present investigation was carried out on one hundred currency notes of all the denominations (50, 100, 250, 500 and 1000RY), obtained from different occupational mainly bus drivers, hawker street, vegetable vendor, restaurants and butchers and fish seller groups in Taiz city,Yemen. Identification and characterization revealed active participation of the following species of organisms in the ascending order of percentage as E. coli(50.28 %),Staphylococci aureus(14.04 %), Klebsiellaspp(4.39 %),proteus(4.39 %), salmonella(1.25 %), shigella(0.72 %), Coagulase negative staphylococcus(0.60 %), pseudomonas(0.50 %), beta haemolytic streptococcus(0.30 %),spore forming gram positive bacilli(0.30%) and alpha haemolytic streptococcus(0.10%). The study suggested that yemenicurrency notes is commonly contaminated withpathogenic microorganisms and this contamination may play a significant role in the transmission of potentiallyharmful microorganisms or different diseases such as cholera, diarrhea, skin infections and also poses antibioticresistant, so great care should be taken during handling of money and the preparation and handling of foodto avoid cross contamination.

Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Improved throughput of Elliptic Curve Digital Signature Algorithm (ECDSA) processor implementation over Koblitz curve k-163 on Field Programmable Gate Array (FPGA)
...Show More Authors

            The widespread use of the Internet of things (IoT) in different aspects of an individual’s life like banking, wireless intelligent devices and smartphones has led to new security and performance challenges under restricted resources. The Elliptic Curve Digital Signature Algorithm (ECDSA) is the most suitable choice for the environments due to the smaller size of the encryption key and changeable security related parameters. However, major performance metrics such as area, power, latency and throughput are still customisable and based on the design requirements of the device.

The present paper puts forward an enhancement for the throughput performance metric by p

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics (ijp)
Study the Effect of Graphene on the Contact Angle, Water Absorption and Thermal Stability ( TGA ,DSC) for Blend (Epoxy & Repcoat ZR)
...Show More Authors

In this study, polymeric coating was developed by incorporating nano graphene in the polymer blend with applications to oil storage tanks. The oil storage tanks samples were brought from the oil Pipeline Company / Doura refinery in Baghdad. The coating polymer was formed with a blend (epoxy resin and repcoat ZR). The proportion of mixing the mixture was 3:1:1 epoxy resin 21.06 gm: repcoat ZR 10.53 gm: hardener 10.53 gm. The blend/graphene was prepared using in stui-polymerization method with different weight percentage 1, 3, 5, and 7 wt % added to blend. The resulting solution was put in a glass tube on a magnetic stirrer for one hour at a temperature of 40 °C. The result of contact angle and water absorption the best ratio of 3wt

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Sep 03 2019
Journal Name
Rawal Medical Journal
Evaluation of Radial Nerve Injury Associated with Closed Humeral Shaft Fracture by Early Pre-operative Ultrasonic Evaluation and Correlation with Surgical Exploration
...Show More Authors

Traumatic radial nerve injury in humeral shaft fracture is the most common traumatic nerve injury in long-bone fracture, with overall prevalence 2-18%, ranging from traction to complete transection. Spontaneous recovery may reach 88%. The aim of the study is to assess the sensitivity & specificity of the ultrasound to detect the radial nerve injury and to see if this can be used as a diagnostic test. This is a prospective study on 17 adult patients with a closed fracture of the humeral shaft, dividing into two groups, the first group of 7 patients had signs and symptoms of radial nerve palsy at presentation and the second group of 10 patients had intact radial nerve function was considered as a control group. All these patients had at leas

... Show More
View Publication Preview PDF
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Materials Science In Semiconductor Processing
A dual S-scheme g-C3N4/Fe3O4/Bi2WO6/Bi2S3 heterojunction for improved photocatalytic decomposition of methylene blue: Proposed mechanism, and stability studies
...Show More Authors

View Publication
Scopus (58)
Crossref (54)
Scopus Clarivate Crossref
Publication Date
Mon Jun 30 2025
Journal Name
Modern Sport
The Instantaneous Push Force Indicator and Its Relationship to Lower Limb Explosive Power and Selected Biomechanical Variables of the Salto forward tucked
...Show More Authors

View Publication
Crossref
Publication Date
Mon Mar 09 2015
Journal Name
Monthly Notices Of The Royal Astronomical Society
A reliable iterative method for solving Volterra integro-differential equations and some applications for the Lane–Emden equations of the first kind
...Show More Authors

View Publication
Crossref (8)
Crossref
Publication Date
Thu Oct 15 2020
Journal Name
International Journal Of Energy Research
Mixed-ligand complexes of ampicillin derived Schiffbase ligand and Nicotinamide: Synthesis, physico-chemical studies, DFT calculation, antibacterial study and molecular docking analysis
...Show More Authors

A novel series of mixed-ligand complexes of the type, [ML 1 (L 2 ) 3 ]Cl x [M = Cr(III), Fe(III), Co(II),Ni(II), Cu(II), Cd(II) and Hg(II), n = 2, 3], was synthesized using Schiffbase (HL 1 ) as main ligand, nicotinamide (L 2 ) as secondary ligand, and the corresponding metal ions in 1:3:1 molar ratio. The main ligand, HL 1 was prepared by the interaction of ampicillin drug and 4-chlorobenzophenone. The synthesized mixed ligand complexes were characterized by elemental analysis, UV-Vis, FT-IR, 1 H-NMR, 13 C-NMR and TG/DTG studies. In the mixed-ligand complexes, the Schiffbase ligand, HL 1 showed coordination to the central metal ion in tridentate manner via azomethine nitrogen, β-lactam ring oxygen and deprotonated carboxylic oxy- gen atom

... Show More
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The synergistic effect of Zeolites type (?) with chlorinated rubber as flame retardants for unsaturated polyester resin: Jalil R. Ugal| Zahraa Q. Mahdi
...Show More Authors

In this work, the synergistic effect of chlorinated rubber (additive I),with zeolite 3A (additive II), zeolite 4A (additive III), and zeolite 5A (additive IV) in (1:1) weight percentage, on the flammability for unsaturated polyester resin was studied in the weight ratios for (3,7,10,13&15%) by preparing films of (130×130×3) mm in diameters. Three standard test methods used to measure were the flame retardation which are; ASTM: D-2863, ASTM: D- 635& ASTM: D-3014. Results obtained from these tests indicated that all of the additives were effective additive IV has the highest efficiency as a flame retardant.

View Publication
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
The relationship of Nuclear Decay Methods (alpha and beta) Particles with the Nuclear Deformation for Nuclei inUranium-238 and Thorium -232 Series
...Show More Authors

View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular

... Show More
View Publication Preview PDF