This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the appl
... Show More The current research aims at transforming the concept of implication from the rhetoric into the industrial design in order to have a new term (the design implication) in which the industrial designer takes all or part of another's design to imply his design in it and acknowledge that, and if he did not do so, it would be (design theft) parallel to the literary plagiarism.
In order to show the potentials of the industrial design in the production of new formulations of the industrial products forms, as the design is the carrier of language that addresses the recipients, it is possible to use the implication as a the tool of literature in the design and as a design strategy as it is one of the concepts that takes its course in e
Background: A noninvasive method of determining the severity of coronary artery disease (CAD) is the use of cardiac biomarkers. This study aimed to investigate the use of serum levels of high-sensitivity cardiac troponin I (hs-cTnI) and N-terminal pro–B-type natriuretic peptide (NT-proBNP) in determining CAD severity.Methods: This cross-sectional study included 125 participants categorized by coronary angiographic results into 3 groups: group I (no or < 50% stenosis), group II (1 or 2 vessels with ≥ 50% stenosis), and group III (left main stem or ≥ 3 vessels with ≥ 50% obstruction). Serum hs-cTnI and NT-proBNP levels were measured by enzyme-linked immunosorbent assay. Data were analyzed using SPSS version 25.0 and described as pe
... Show MoreForty-eight aborted women (Iraqi Arab Muslims) at the first trimester with a serological evidence of toxoplasmosis were investigated. Two age- and ethnic-matched control groups were included: 40 aborted women due to accidental events (Control I), and 40 unmarried (virgin) women (Control II). The subjects were evaluated for the following parameters: HLA-class I antigens (A, B and Cw), blood groups, total and differential counts of leukocytes, lymphocyte subpopulations (CD3+, CD4+ and CD20+ cells), phagocytosis of heat-killed yeast (phagocytic index and NBT index), and total serum levels of immunoglobulins (IgA, IgG and IgM) and complement components (C3 and C4). The HLA-A2 and -Cw8 antigens were significantly increased in the patien
... Show MoreThe major objective of this study is to establish a network of Ground Control Points-GCPs which can use it as a reference for any engineering project. Total Station (type: Nikon Nivo 5.C), Optical Level and Garmin Navigator GPS were used to perform traversing. Traversing measurement was achieved by using nine points covered the selected area irregularly. Near Civil Engineering Department at Baghdad University Al-jadiriya, an attempt has been made to assess the accuracy of GPS by comparing the data obtained from the Total Station. The average error of this method is 3.326 m with the highest coefficient of determination (R2) is 0.077 m observed in Northing. While in
In the recent years, remote sensing applications have a great interest because it's offers many advantages, benefits and possibilities for the applications that using this concept, satellite it's one must important applications for remote sensing, it's provide us with multispectral images allow as study many problems like changing in ecological cover or biodiversity for earth surfers, and illustrated biological diversity of the studied areas by the presentation of the different areas of the scene taken depending on the length of the characteristic wave, Thresholding it's a common used operation for image segmentation, it's seek to extract a monochrome image from gray image by segment this image to two region (for
... Show MoreNew complexes of M(II) with mixed ligand of 5-Chlorosalicylic acid (CSA) C7H5ClO3 as primary ligand and L- Valine (L-Val) C5H11NO2 as a secondary ligand were prepared and characterized by elemental analysis (C.H.N), UV., FT-IR, magnetic susceptibility, µeff (B.M) as well as the conductivity measurements (Λm ). In the complexes, the 5-chlorosalicylic acid is bidentate in all complexes coordinating through –OH- and –COO- groups; also L-Valine behaves as a bidentate ligand in all complexes through –NH2 and –COO- groups. These five mixed ligand complexes formulated as Na3[M(CSA)2(L-Val)]. The proposed molecular structure for all complexes is octahedral geometries. The synthesis complexes were tested in vitro for against four bacteria
... Show MoreNew complexes of M(II) with mixed ligand of 5-Chlorosalicylic acid (CSA) C7H5ClO3 as primary ligand and L- Valine (L-Val) C5H11NO2 as a secondary ligand were prepared and characterized by elemental analysis (C.H.N), UV., FT-IR, magnetic susceptibility, μeff (B.M) as well as the conductivity measurements (Λm ). In the complexes, the 5-chlorosalicylic acid is bidentate in all complexes coordinating through –OH- and –COO- groups; also L-Valine behaves as a bidentate ligand in all complexes through –NH2 and –COO- groups. These five mixed ligand complexes formulated as Na3[M(CSA)2(L-Val)]. The proposed molecular structure for all complexes is octahedral geometries. The synthesis complexes were tested in vitro for against four bacteria
... Show MoreMaximum likelihood estimation method, uniformly minimum variance unbiased estimation method and minimum mean square error estimation, as classical estimation procedures, are frequently used for parameter estimation in statistics, which assuming the parameter is constant , while Bayes method assuming the parameter is random variable and hence the Bayes estimator is an estimator which minimize the Bayes risk for each value the random observable and for square error lose function the Bayes estimator is the posterior mean. It is well known that the Bayesian estimation is hardly used as a parameter estimation technique due to some difficulties to finding a prior distribution.
The interest of this paper is that
... Show More